PubMed Health⌕ Search

Biomedical subjects

D Jakrapanichakul

Publications and source records attributed to D Jakrapanichakul.

3 recordsLinked to original sources

Rapid three-dimensional echocardiography : clinically feasible alternative for precise and accurate measurement of left ventricular volumes.

BACKGROUND: Clinical applicability of conventional ultrasonographic systems using mechanical adapters for 3D echocardiographic imaging has been limited by long acquisition and processing times. We developed a rapid (6-s) acquisition technique that collects apical tomograms using a continuously internally rotating transthoracic transducer. This study was performed to examine the clinical feasibility of rapid-acquisition 3D echocardiography to estimate left ventricular end-diastolic and end-systolic volumes using electron-beam computed tomography as the reference standard. Methods and Results-We collected a series of 6 to 11 apical echocardiographic tomograms, depending on heart rate, in 11 patients. There was good correlation, low variability, and low bias between rapid 3D echocardiography and electron-beam computed tomography for measuring left ventricular end-diastolic volume (r=0.96; standard error of the estimate, 21.34 mL; bias, -4.93 mL) and left ventricular end-systolic volume (r=0.96; standard error of the estimate, 14.78 mL; bias, -6.97 mL). CONCLUSIONS: The rapid-acquisition 3D echocardiography extends the use of a multiplane, internally rotating handheld transducer so that it becomes a precise and clinically feasible tool for assessing left ventricular volumes and function. A rapid-image acquisition time of 6 s would allow repeated image collection during the course of a clinical echocardiographic examination. Additional work must address rapid and automated data processing.

Adult↗

Shape reconstruction of the left ventricle: accuracy of limited-plane three-dimensional echocardiography.

OBJECTIVE: To assess the accuracy of left ventricular cavity shape reproduction from 8 spatially related, apical two-dimensional ultrasonographic images. METHODS: We scanned 6 dog heart specimens. Left ventricular cavity casts were reconstructed from 48-tomogram (high-density), 8-tomogram (octaplane), and 2-tomogram (low-density biplane) apical data sets. The 48-plane left ventricular cast served as the reference. Spatial shape resolution of 3 mm in radial distance from the rotational axis to the interpolated endocardium was used as the criterion of shape accuracy. RESULTS: The adjusted limits of agreement for the octaplane and biplane left ventricular casts were +/-2.31 and +/-6.84 mm, respectively. CONCLUSIONS: The three-dimensional left ventricular cavity shape can be accurately reproduced by using a low-data density apical octaplane echocardiographic examination.

Animals↗

Relationship between exercise capacity and left ventricular function in aortic and mitral regurgitation.

The exercise capacity as assessed by treadmill exercise or functional class from clinical history cannot predict standard echocardiographic findings in patients with AR/MR, in terms of EF, LVDs, ESVI. Therefore, exercise capacity cannot be used to predict the timing for surgery in those patients. However, symptomatic patients with dilated LV usually have low LVEF such as in our group.

Adolescent↗