PubMed Health⌕ Search

Biomedical subjects

D K Lowther

Publications and source records attributed to D K Lowther.

6 recordsLinked to original sources

Criteria for in vitro alternatives for the eye irritation test.

A proposal encompassing considerations and criteria for the development of in vitro alternatives to the eye irritation test has been developed and is presented here. Two factors need to be considered initially in developing an alternative test. The first is to determine whether the alternative assay is to be used as a screen or as a replacement for the eye irritation test. Less stringent acceptance criteria are required for an assay used as a screen than for that used as a replacement test. A screen is a preliminary test for the assessment of eye irritation. It is used for making preliminary decisions or establishing the direction for further testing. Screens answer fewer and less complex questions than a replacement test would, since the results from screens are usually confirmed by more definitive testing. A replacement test, however, must provide the same answers as in vivo methods for the assessment of eye irritation and must provide data for making a definitive toxicological assessment of eye irritation. The second factor to be considered is knowledge of the in vivo assay intended to be replaced. This knowledge should include the procedural aspects of the test and the regulatory information it provides. The following may be considered as criteria for in vitro tests used as screens or as replacements for the eye irritation test in rabbits: rationale (there should be a clear statement regarding the rationale for the use of a particular test in relation to the availability of other tests); relevance (the in vitro endpoint should have biological or physiological relevance to the effect to be detected in vivo); and validational (intralaboratory as well as interlaboratory validation must be conducted).

Animal Testing Alternatives↗

Screening procedures for eye irritation.

Screens aid in identifying some severe irritants or corrosives and eliminating them from consideration for in vivo eye irritation testing. Products may be evaluated for ocular irritation potential in a stepwise progression as follows: (1) products at pH extremes of 2 or below or of 11.5 or above may be considered to be ocular irritants; (2) based on chemical structure-activity considerations, some products may be judged to have ocular irritation potential; (3) validated and accepted in vitro systems may possibly be used as a screen in the future; (4) when a test material demonstrates severe acute dermal toxicity (lethality at < or = 200 mg/kg body weight), further testing for either dermal or ocular irritation may not need to be undertaken; (5) if a substance shows a primary dermal irritation index of 5 or above, it may be considered to be an ocular irritant; (6) materials that are not removed from consideration based on these proposed screens may then be considered for testing for ocular irritation in rabbits under accepted procedures. In a survey given to participants in the workshop, a high percentage believed that screens should be used. However, opinions on the use of the individual screens varied between the different interested groups attending, with the possible future use of in vitro screens for specific product lines having the highest percentage of agreement (57-100%).

Animal Testing Alternatives↗

The use of low-volume dosing in the eye irritation test.

The Draize rabbit eye test was developed to provide a method for assessing the irritation potential of materials that might come in contact with human eyes. The method involves the instillation of 0.1 ml of a test liquid (100 mg solid) into the conjunctival sac of an animal's eye. A refinement of the Draize test is the low-volume eye test in which 0.01 ml of a substance is placed directly on the cornea of the eye. Studies indicate that the low-volume method provides a better correlation to human eye irritation experience for some substances. The Interagency Regulatory Alternatives Group (IRAG) proposes that the low-volume eye test can be used to substantiate the irritancy of suspect severe ocular irritants that have not been eliminated by various pre-eye test 'screens'. A substance testing positive by the low-volume method can be classified as an irritant; one that tests negative will require further testing by the use of the 0.1-ml volume procedure. For all other definitive testing, the Draize test (0.1 ml) should be used. Results from a questionnaire distributed at the IRAG workshop showed that many workshop participants thought that the low-volume test should be used as an eye irritation screening procedure.

Animal Testing Alternatives↗

An eye irritation test protocol and an evaluation and classification system.

An in vivo test protocol and an evaluation and classification system for the determination of eye irritation potential of chemicals and mixtures (substances) is proposed. The protocol uses two or three rabbits and reduces distress in test animals. The test substances are classified as non-irritant, irritant or severe irritant to meet regulatory needs. They may be classified on the basis of past experience with similar compounds or mixtures. Screens such as structure-activity relationships, pH extremes, validated and accepted in vitro tests, severe dermal irritation (primary dermal irritation index > or = 5) or severe dermal toxicity (lethality at < 200 mg/kg body weight) should be used to classify irritant or severe irritant materials when one or more of the screens can provide convincing evidence. For suspected severe irritant materials, the proposed in vivo test permits the use of one rabbit and instillation of 0.01 ml (0.01 g) of the test material into the cornea. Materials that are not classified irritant or severe irritant by screens or severe irritant by one rabbit test are tested in two or three rabbits; 0.1 ml (0.1 g) is instilled into the conjunctival sac. The responses (corneal opacity, iritis and conjunctival redness) are scored according to the modified Draize scoring system at 24, 48 and 72 hr and 7 days post-instillation. A rabbit is considered positive when corneal opacity of 1 or above, iritis of 1 or above or conjunctival redness of 2 or above is present at 24, 48 or 72 hr post-instillation. The material is classified as a severe irritant when the rabbit in the one-animal test or two or more rabbits in the standard test have responses of corneal opacity of 3 or above and iritis of 2 at 24, 48 or 72 hr, or positive responses on day 7 after instillation. The material is classified as an eye irritant when two or more rabbits are positive but the responses are not severe and they clear 7 days after instillation. The material is classified as a non-irritant when no more than one rabbit is positive. The opinions expressed in this article are those of the authors and do not necessarily reflect the views of US Federal agencies.

Animals↗

Biochemical response of rat lung to inhaled n-hexane.

Biochemical response of the rat lung to inhaled n-hexane was investigated. Dose-dependent increase in protein, lipid, sialic acid, lactate dehydrogenase, angiotensin-converting enzyme, acid and alkaline phosphatase was observed in the cell-free lavage effluent of the lungs of exposed rats compared to the control animals. This was interpreted as enhanced pulmonary secretions accompanied by increased cell damage.

Animals↗