Persistent nodule on the toe following trauma. Sporotrichoid Mycobacterium marinum infection.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D K Murdock.
Explore the source record for details and available documents.
To investigate the relationship between clot formation and thromboembolism, canine blood was withdrawn into catheter-syringe or catheter-steerable wire systems containing either contrast medium or normal saline as used in debubbling techniques. The contrast media used were iohexol, iopamidol, ioxaglate, and diatrizoate. Without the use of heparin, after a 30-minute incubation, blood clots were harvested from all catheter-syringe systems except those with diatrizoate and from all catheter-steerable wire systems. Significantly more blood clot was harvested from the catheter-steerable wire system. With use of heparinized blood, no clot was found in any system. Twelve dogs that underwent coronary angiography were divided into two groups; one received heparin (5,000 IU) and the other did not. Thromboembolism occurred in all nonheparinized dogs that underwent angiography with iohexol or iopamidol but not in any other group. The authors found that in a dog model nonionic contrast media are more thrombogenic than ionic contrast media, especially in the catheter-steerable wire system. The blood clot in the catheters is associated with thromboembolism during angiography. The authors maintain that in this setting, blood clotting and thromboembolism with nonionic agents can be eliminated with heparin.
Explore the source record for details and available documents.
To investigate the effect of sodium on cardiac hemodynamics, sodium chloride was added to nonionic contrast media to a 0.9% concentration and was compared with the standard media iohexol, iopamidol, and ioversol. Left coronary angiography was performed in 10 closed-chest, atrial-paced dogs with 10 ml injections of each preparation in a randomized and blinded fashion. The maximum changes in left ventricular systolic pressure, mean aortic pressure, left ventricular and diastolic pressure, and maximal rise of left ventricular pressure were measured. The left ventricular systolic pressure and mean aortic pressure decreased by 17 +/- 7 mm Hg and by 12 +/- 5 mm Hg with iohexol plus 0.9% NaCl, but only by 5 +/- 4 mm Hg and by 4 +/- 3 mm Hg with iohexol alone (p less than 0.001). The left ventricular and end diastolic pressure increased by 2.2 +/- 0.6 mm Hg with iohexol plus 0.9% NaCl, but did not change with iohexol alone (p less than 0.001). Left ventricular dp/dt decreased by 204 +/- 161 mm Hg/sec with iohexol plus 0.9% NaCl but increased by 392 +/- 122 mm Hg/sec with iohexol alone (p less than 0.001). Similar results were obtained from experiments with iopamidol versus iopamidol plus 0.9% NaCl and ioversol versus ioversol plus 0.9% NaCl. Ioversol plus 5% dextrose or ioversol plus 2.1% choline chloride (isomolar to ioversol plus 0.9% NaCl) produced a significant increase in left ventricular systolic pressure and left ventricular dp/dt (versus ioversol plus 0.9% NaCl, p less than 0.001). Thus, sodium, but not the osmolality or chloride, contributed to the negative inotropic effect of the contrast media.(ABSTRACT TRUNCATED AT 250 WORDS)
Contrast media occasionally produce bradyarrhythmias defined as a 25% decrease in heart rate and/or developing atrioventricular block during coronary angiography. Twelve left coronary angiographies and seven right coronary angiographies were performed with 10 ml of diatrizoate meglumine and diatrizoate sodium (Renografin-76 [R76] or Hypaque [H76]) or iopamidol (Isovue 370 [ISO]) in a blinded randomized fashion. Heart rate decreased significantly from 135 +/- 5 to 120 +/- 5 beats/min (p less than 0.001) with R76, to 127 +/- 7 beats/min (p less than 0.01) with H76, and to 130 +/- 6 beats/min (p less than 0.05) with ISO in left coronary angiographies; more profound decrease was observed in right coronary angiographies from 134 +/- 4 to 87 +/- 18 beats/min (p less than 0.001) with R76, to 99 +/- 14 beats/min (p less than 0.001) with H76, and to 125 +/- 7 beats/min (p less than 0.01) with ISO. In 12 left coronary angiographies bradyarrhythmia was observed in five cases with R76, two with H76, and none with ISO. In seven right coronary angiographies it occurred in six with R76, three with H76, and none with ISO. The differences in the incidence of bradyarrhythmia between R76 and ISO were significant during left and right coronary angiographies (p less than 0.05 and p less than 0.01, respectively). Thus ionic contrast media produced more marked bradyarrhythmias than nonionic contrast media in coronary angiography, especially R76. Right coronary angiography resulted in more profound bradyarrhythmias than left coronary angiographies. This study suggested that nonionic contrast media (ISO) might be preferable to ionic contrast media (R76 or H76) for coronary arteriography.
The hemodynamic effects induced by coronary angiography in dogs with low osmolar ionic dimer Hexabrix (HB) and nonionic Omnipaque-350 (OM) were compared to the standard ionic contrast medium, Hypaque-76 (H76), both in the normal heart and in one with simulated severe cardiac disease. Left coronary angiography was performed in 12 "normal" closed-chest dogs with 10-cc injections of H76, HB, and OM in a randomized, blinded fashion. The maximal change in the left ventricular (LV) systolic pressure (SP), mean aortic pressure (MAP), left ventricular end diastolic pressure (LVEDP), and LV dp/dt were recorded. The LVSP and MAP fell 30 +/- 3 mm Hg and 26 +/- 4 mm Hg with H76, 22 +/- 2 mm Hg and 19 +/- 2 mm Hg with HB, and 7 +/- 1.5 mm Hg and 5 +/- 1 mm Hg with OM (P less than .001). The LVEDP increased 4.8 +/- 0.5 mm Hg with H76, 3 +/- 0.5 mm Hg with HB, but only 0.2 mm Hg with OM (P less than .001). The LV dp/dt decreased 392 +/- 63 mm Hg/sec with H76 and 235 +/- 21 mm Hg/sec with HB, but increased 411 +/- 50 mm Hg with OM (P less than .001). In eight additional open-chest dogs, left coronary angiography was performed 1 hr after occlusion of the proximal LAD coronary artery and in the presence of a critical circumflex coronary artery (CX) stenosis.(ABSTRACT TRUNCATED AT 250 WORDS)
The influence of contrast media on coagulation has an important association with thromboembolic complication during coronary angiography. In this study, whole blood was methodically mixed with nonionic contrast medium, Iohexol (IOH), conventional ionic contrast medium, Hypaque-76 (H76), and low osmolar ionic dimer Hexabrix (HB) in vitro. The thrombotic propensity of contrast agents can be evaluated by measuring the clot formation of the mixtures. The experiments were repeated with whole blood after systemic heparinization. In the in vitro study, 5 ml of canine (N = 10) and 3 ml of human (N = 11) whole blood was incubated for 30 min in glass tubes with equal volumes of IOH, H76, HB, and 0.9% NaCl before heparinization. Clot formation with IOH and 0.9% NaCl were seen both in dogs (4.0 +/- 0.7 gm and 5.6 +/- 0.8 gm) and in patients (1.4 +/- 0.9 gm and 2.9 +/- 1.3 gm), whereas no clot was seen with H76 or XB. Following heparinization, no clot was visualized in any mixture of whole blood with contrast media or 0.9% NaCl. Similar results were observed in the catheter-syringe system with canine blood (N = 11) mixed with the contrast agents. Blood clots found in 15 min and 30 min of IOH were 0.07 +/- 0.08 gm and 0.44 +/- 0.20 gm (P less than 0.01) and of NaCl were 0.29 +/- 0.37 gm and 0.69 +/- 0.38 gm (P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
The eruptive vellus hair cyst is an uncommon, yet distinct, clinical and pathological entity that may be acquired in a sporadic or hereditary form. This descriptive term gives no indication of the type of epithelium lining this cyst. A case report of eruptive vellus hair cyst is reported herein in which the epithelial lining differentiated toward the sebaceous duct. We propose that eruptive vellus hair cysts should be more accurately diagnosed by characterizing the type of epithelial lining.
Coronary angiography with standard ionic contrast media is associated with marked alterations in cardiac hemodynamics because of the depressant effects of the contrast media on cardiac contractility. Nonionic contrast media have been reported to produce less hemodynamic alteration than standard ionic contrast media. However, there is no information on how one nonionic media compares to another. Thus we compared the hemodynamic effects of three nonionic contrast media, Iopamidol (IOP), Iohexol (IOH), and Ioversol (IOV) to each other as well as to the standard ionic contrast media Hypaque-76 (H76). In 20 closed-chest anesthetized dogs, we recorded the maximal change in left ventricular systolic pressure (LVSP), mean aortic pressure, left ventricular diastolic pressure (LVDP), and left ventricular dp/dt during 10-cc left main coronary artery injections of H76, IOP, IOH, and IOV. The mean aortic pressure and LVSP decreased 36 +/- 17 mm Hg and 46 +/- 21 mm Hg with H76 but only 5 +/- 5 mm Hg and 6 +/- 5 mm Hg with IOP, 5 +/- 4 mm Hg and 6 +/- 6 mm Hg with IOH, and 5 +/- 4 mm Hg and 7 +/- 6 mm Hg with IOV (P less than 0.001). The LVDP increased 6 +/- 5.0 mm Hg with H76 but only 0.2 +/- 0.5 mm Hg with IOP, 0.2 +/- 0.3 mm Hg with IOH, and 0.5 +/- 1.0 mm Hg with IOV (P less than 0.001). The LV dp/dt decreased 545 +/- 261 mm Hg/sec with H76 but increased 886 +/- 477 mm Hg/sec with IOP, 910 +/- 96 mm Hg/sec with IOH, and 473 +/- 335 mm Hg/sec with IOV (P less than 0.001). Whereas each nonionic agent produced significantly less hemodynamic abnormalities than H76, there was no significant difference between any of the nonionic agents on any hemodynamic parameter. Thus, as compared to H76, these nonionic contrast media produced only trivial alterations in hemodynamics and LV dp/dt. These agents may be preferable in patients with LV dysfunction.
Hypaque-76 (H76) and Renografin-76 (R76) are nearly identical ionic contrast media, except that R76 binds more calcium than H76 because of the presence of sodium citrate and EDTA in R76. To determine whether the calcium-binding additives in ionic contrast media contribute to the hemodynamic effects of contrast media during coronary angiography, left coronary angiography was performed in anesthetized dogs. In nine closed-chest dogs, 10 cc of H76 and R76 were injected in each dog in a blinded, randomized fashion. The effect of H76 and R76 on left ventricular systolic pressure (LVSP) and left ventricular diastolic pressure (LVDP), on mean aortic pressure (MAP), and on left ventricular (LV) dp/dt was recorded. Compared with H76, R76 produced a greater decrease in the LVSP (77 +/- 25 mmHg vs 48 +/- 17 mmHg P less than .05), MAP (72 +/- 24 mmHg vs 38 +/- 18 mmHg P less than .01), and LV dp/dt (747 +/- 87 mmHg/sec vs 460 +/- 81 mmHg/sec P less than .01). In nine additional open-chest dogs, left coronary angiography was performed 1 hour after occlusion of the proximal LAD coronary artery. Seven cc R76 produced a 35 +/- 15 mmHg decrease in LVSP, compared with 20 +/- 9 mmHg with H76 (P less than .01). The LV dp/dt decreased 720 +/- 387 mmHg/sec with R76, compared with 462 +/- 222 mmHg/sec with H76 (P less than 0.05). Thus, R76 produces significantly greater hemodynamic abnormalities than H76. Contrast media lacking calcium-binding agents may be preferable for coronary angiography.
Contrast media occasionally produce ventricular fibrillation during coronary angiography. We compared the fibrillatory propensity of the conventional ionic contrast medium, Hypaque-76 (H76) to the low osmolar ionic dimer Hexabrix (HB) and to the nonionic agent Omnipaque (OM) in 20 open chest anesthetized dogs. Intracoronary injection of 6 mL of contrast medium produced spontaneous ventricular fibrillation in four of ten dogs with H76, compared with two of ten with HB, and zero of ten with OM (P = .07). The induction of two premature beats by programmed stimulation of the myocardium during injection of 4 mL of contrast medium produced ventricular fibrillation in ten of ten dogs with H76, compared with three of ten with HB, and zero of ten with OM (P less than .001). Both H76 and HB produced ventricular fibrillation in ten of ten dogs when three premature beats were induced, compared with two of ten dogs with OM (P less than .001). Four mL H76 produced a 109 +/- 18 msec increase in the QT interval, compared with an 82 +/- 17 msec increase with HB, and a 45 +/- 12 msec increase with OM. We conclude that both low osmolar HB and OM are less fibrillatory than the conventional ionic medium H76, and that the nonionic medium OM is less fibrillatory than the ionic dimer contrast medium HB.
Electrocardiographic changes induced by ionic contrast media can cause complications during coronary angiography. A conduction delay through various parts of the heart is one factor in the genesis of asystole or ventricular fibrillation. Hypaque-76 (H76) and Renografin-76 (R76) are nearly identical ionic contrast media except that R76 binds more calcium than H76 because of the presence of sodium citrate and EDTA in R76. To determine whether the calcium binding additives in ionic contrast media contribute to the cardiac conduction abnormalities, we examined conduction time through the atrioventricular (AV) nodal tissue (via bipolar His bundle electrograms) and through the distal part of the conduction system (recording the QRS complex from the ECG) during coronary angiography. We injected 10 mL of H76 and R76 in 19 closed chest dogs in a blinded, randomized fashion during coronary angiography. The effects of H76 and R76 on heart rate, AH interval, HV interval, V interval and PR interval, and QRS complex duration were recorded. In 14 nonatrial pacing dogs, compared with H76, R76 produced a greater increase in the AV interval (32.9 +/- 6 milliseconds vs 12.4 +/- 2 milliseconds, P less than .01) and the PR interval (29.6 +/- 6 milliseconds vs 11.9 +/- 4 milliseconds, P less than .02). Additionally, the heart rate decreased 13.9 +/- 3.5 beats/minute from control with R76 compared with a decrease of 4.2 +/- 2.6 beats/minute from control with H76 (P less than .05). There was no significant difference between the prolongation of the HV interval and V interval, or QRS complex duration generated by R76 and H76.(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We compared the hemodynamic effects during coronary angiography of three nonionic contrast media, iopamidol, iohexol, and ioversol, with each other as well as with the standard ionic contrast medium containing 66% diatrizoate meglumine and 10% diatrizoate sodium (Hypaque-76) in the presence of a left anterior descending coronary artery occlusion in dogs. In 13 opened-chest anesthetized dogs, we recorded the maximal change in left ventricular systolic pressure (LVSP), mean aortic pressure (MAP), left ventricular diastolic pressure (LVDP) and rate of rise in left ventricular pressure (LV dp/dt) during left main coronary artery injections of 10 ml each of Hypaque-76, iopamidol, iohexol, and loversal 1 hour after left anterior descending coronary artery occlusion. The changes in LVSP and MAP were, respectively, -29 +/- 12 mm Hg and -21 +/- 11 mm Hg with Hypaque-76, 3 +/- 6.6 mm Hg and -0.2 +/- 3.6 mm Hg with iopamidol, 4.8 +/- 8.6 mm Hg and 0.5 +/- 4 mm Hg with iohexol, and -0.8 +/- 6 mm Hg and -1.5 +/- 33 mm Hg with ioversal (p less than 0.001). The change in LVDP was 5.4 +/- 4.4 mm Hg with Hypaque-76 but -1.5 +/- 3.1 mm Hg with iopamidol, -1.7 +/- 2.4 mm Hg with iohexol, and -0.5 +/- 2.5 mm Hg with ioversol (p less than 0.001). The LV dp/dt decreased 682 +/- 318 mm Hg/sec with Hypaque-76, but increased 412 +/- 297 mm Hg/sec with iopamidol, 350 +/- 214 mm Hg/sec with iohexol, and 293 +/- 191 mm Hg/sec with ioversol (p less than 0.001). Thus, each nonionic agent produced significantly fewer hemodynamic abnormalities than Hypaque-76. There was no significant difference between any of the nonionic agents on any hemodynamic parameter. These agents may be preferable in patients with acute myocardial infarction or significantly impaired myocardial function.
Removing sodium from standard ionic contrast media markedly increases the incidence of ventricular fibrillation in patients undergoing coronary angiography. Newer nonionic contrast media, iopamidol, iohexol, and ioversol contain only trace amounts of sodium. To determine whether sodium attenuates or potentiates ventricular fibrillation from nonionic contrast media, we measured the prolongation in QT interval and performed programmed electrical stimulation with one, two and three extra ventricular stimuli in 40 dogs during 4-mL intracoronary injections of iopamidol, iohexol, and ioversol. Solutions of each contrast medium with added NaCl at concentrations of 0.225%, 0.45%, and 0.9% were compared with standard contrast media. The addition of NaCl markedly increased the amount of QT interval prolongation produced by each contrast medium. With iopamidol, the amount of QT interval prolongation was 40 +/- 11 msec with standard iopamidol, but was 58 +/- 11 msec with 0.225% NaCl/iopamidol, 84 +/- 17 msec with 0.45% NaCl/iopamidol, and 132 +/- 42 msec with 0.9% NaCl/iopamidol (P less than .001). Similar results were seen with iohexol and ioversol. Ventricular fibrillation was difficult to induce with standard solutions of these agents (even with three extra stimuli), but became progressively easier to induce when NaCl was added. Three extra stimuli produced ventricular fibrillation in zero of 11 dogs with standard iopamidol, zero of 11 with 0.225% NaCl/iopamidol, three of 11 with 0.45% NaCl/iopamidol, and eight of 11 with 0.9% NaCl/iopamidol (P less than .001). Similar results were observed with iohexol and ioversol. The addition of choline chloride or dextrose did not increase ventricular fibrillation and QT interval prolongation. It is concluded that standard preparations of nonionic contrast media have a very low fibrillatory propensity.(ABSTRACT TRUNCATED AT 250 WORDS)