[Increased physical activity due to intermittent self-ventilation in chronic respiratory insufficiency].

BACKGROUND: Nocturnal mechanical ventilation (NMV) can reduce symptoms of hypoventilation and improve gas exchange in patients with chronic respiratory failure but there is no data concerning the impact of nocturnal mechanical ventilation on daily activity. We prospectively measured daily activity as judged by total steps per day. PATIENTS AND METHODS: Thirty stable patients (17 men, mean age 55.2 years, pCO2: 62.3 +/- 9.0 mmHg) with chronic respiratory failure. DIAGNOSIS: Kyphoscoliosis (n = 11), COLD (n = 7), neuromuscular diseases (n = 6), post-tbc sequelae (n = 6). Applying a pedometer over a 7 day period before and 3 months after initiating nocturnal mechanical ventilation the steps per day were counted. We also obtained arterial blood gases and applied the St. George's Respiratory Questionnaire (scoring range from 0 = complete health to 100 = worst possible). RESULTS AND CONCLUSIONS: The daily activity in patients with hypercapnic respiratory failure as judged by the total amount of steps per day increased by 120% after 3 months of nocturnal mechanical ventilation (from 1606.9 +/- 1341.3 to 3535 +/- 1813.8 steps per day, p < 0.0001). This was associated with a significant improvement in daytime blood gases and quality of life (QoL) as judged by questionnaire (total score: from 61.3 +/- 14.9 to 48.3 +/- 18.7, p = 0.0006). However no correlation between steps per day and QoL was found.

Adult↗

[Pressure versus volume constant ventilation in chronic ventilatory insufficiency].

BACKGROUND: Volume controlled intermittent ventilation (IPPV) via face mask is a treatment of proven efficacy for chronic respiratory failure (CRF). Pressure support ventilation has recently been introduced in the treatment of CRF. In this study we investigated whether pressure constant ventilation (PCV) via face mask could be an adequate long term alternative to IPPV. PATIENTS AND METHODS: We studied 30 (24 male, age: 52.2 +/- 15.9 years) patients with CRF. We measured the following parameters at baseline, after 1, 2 and 6 months, respectively: blood gas analysis, oxygen saturation, vital capacity, forced exspiratory volume, breathing frequency, tidal volume, inspiratory mouth occlusion pressure, maximal inspiratory pressure, subjective symptom scores and ventilator acceptance scores. In all patients, we attempted to treat with IPPV over 1 month, followed by 1 month's trial of PCV. If PCV, compared to IPPV, was adequate, PCV was continued for a follow-up period of 4 months' duration. If patients deteriorated after PCV they were treated the following 4 months with IPPV. RESULTS: In 28 out of 30 patients CRF improved concerning subjective and objective parameters. After IPPV 18 out of 28 patients changed to PCV, with an equal quality of treatment (PCV-responder). Ten patients were PCV-nonresponders since compared to IPPV the subjective scores deteriorated and the PaCO2 increased again. In all patients of either therapy group, subjective and objective parameters remained constant for another 4 months period. At baseline the PCV-nonresponders had significantly higher degree of hypercapnia and oxygen desaturation; no other parameters were found to be of predictive value concerning the efficacy of PCV. CONCLUSIONS: PCV proved to be an alternative to IPPV in the treatment of chronic respiratory insufficiency in approximately 60% of the patients with CRF. However there is a subgroup with more severe CRF at baseline in whom PCV is inadequate.

Adult↗

[Value of various intra- and extraoral therapeutic procedures for treatment of obstructive sleep apnea and snoring].

BACKGROUND: Recently intra- and extraoral devices are increasingly used in order to treat obstructive sleep apnea (OSA) and snoring. We examined the value of some devices according to the literature and our own results. PATIENTS AND METHODS: The mandibular advancing devices aim at increasing upper airway diameter. The active part of the tongue extending device (SnorEx) is a stamp connected to a piston which exerts pressure at the base of the tongue causing its forward displacement; we studied 23 patients. The principle of an optically stimulating system ("eye-cover", Snore-Stop) consists of a microphone and light diods which are integrated in the eye-cover. After detecting acoustic signals (for example snoring) optical stimuli are generated in front of the eyes, which are thought to induce arousals causing a change of body position and the reduction of the snoring and apneas; we measured 24 patients. The principle of the tongue-retainer (Snore-Master) is the fixation of the tongue in a ventral position, which is thought to enlarge the mesopharyngeal area; we studied 14 patients. The nose plaster (Breathe-Right) contains an elastic spine that pulls the alae nasi cranial. This manipulation is thought to increase the diameter of the nostril and reduce the airway resistance. We measured 30 patients with obstructive sleep apnea and 20 snoring subjects without obstructive sleep apnea. RESULTS: Regarding the mandibular advancing due to different appliance designs and study protocols variable success rates have been documented. In patients with mild to moderate obstructive sleep apnea a reduction of the sleep related breathing disorder could be shown. Non compliance (NC) to the tongue extending device was 75% (17/23). Non-compliance-patients were characterized by unacceptable local-side-effects of the prosthesis, lacking improvement of symptoms and of the respiratory disturbance index. Both tongue-retainer and -extensor are characterized by a high incidence of local side effects. Neither the eye-cover nor the nose plaster could improve the severity of obstructive sleep apnoe or snoring. In contrast to another study we could not show a significant effect of the tongue-retainer. CONCLUSIONS: Neither the nose plaster nor the optical stimulating device influenced the degree of obstructive sleep apnea and snoring. There are conflicting data regarding the tongue retainer. The high rate of non-compliant subjects and the low efficacy of the tongue extending prosthesis precludes large-scale use of this treatment modality in patients with obstructive sleep apnoe and snoring. In selected individuals suffering from a mild to moderate degree of obstructive sleep apnea with CPAP-inefficiency and -incompliance the mandibular advancing principle may be an therapeutic alternative to CPAP.

Equipment Design↗

Endoscopic placement of a tracheal oxygen catheter: a new technique.

OBJECTIVE: In patients with chronic obstructive pulmonary disease (COPD), intratracheal oxygen insufflation (ITO) is an established therapeutic approach. We developed a new endoscopic technique of intratracheal catheter placement. The aim of this pilot study was to demonstrate its short-term feasibility in acutely extubated patients with moderate to severe COPD who require oxygen therapy. DESIGN: A guide wire was inserted through a nasally passed bronchoscope and was positioned such that its tip was placed intratracheally. Using a "Seldinger technique", the tracheal catheter was then inserted over the wire to a point 2-3 cm proximal to the carina and positioned under direct vision from the bronchoscope inserted through the contralateral nose. After catheter insertion, the guide wire was removed. The patients scored catheter-associated local discomfort using a visual analogue scale. In a randomly assigned, crossover design, the effectiveness of the endoscopically (e) inserted ITO catheter was assessed by measuring the capillary blood gases, respiratory rate (RR), tidal volume (Vt) and minute ventilation (MV) after 1 h breathing room air without eITO and 1 h after eITO (flow: 3 l/min). MEASUREMENTS AND RESULTS: The eITO catheter was placed in all patients without complications and with only minimal discomfort in two patients (spontaneously reversible cough). Compared to breathing room air, capillary O2 pressure increased (from 54.7 +/- 9.4 to 82.8 +/- 21.8 mmHg) whereas Vt (from 458.7 +/- 86.8 to 358.3 +/- 75.1 ml) and MV (from 7.7 +/- 1.5 to 5.5 +/- 1.1 l/ min) decreased significantly (each p < 0.0001) with eITO in all patients. The capillary CO2 pressure and RR did not change. CONCLUSIONS: Acutely extubated patients in whom oxygen therapy is indicated may profit from eITO. This new technique works immediately and is thus an effective short-term intervention of potential value in the intensive care unit.

Bronchoscopy↗

CYP2D6 genotype and phenotyping by determination of dextromethorphan and metabolites in serum of healthy controls and of patients under psychotropic medication.

Fourteen drug free healthy volunteers and 22 psychiatric patients under psychotropic medication were phenotyped for their individual CYP2D6 activity using dextromethorphan as a probe drug. A solution containing 20 mg dextromethorphan was administered and blood was taken 60 min later for determination of dextromethorphan and metabolites in serum. For comparison, urine was collected over 8 h after ingestion of 20 mg dextromethorphan in a separate test. The CYP2D6 phenotype was determined from the ratio of dextromethorphan to dextrorphan. For genotyping, mutant alleles of the CYP2D6 gene were identified using allele-specific polymerase chain reactions. Genotyping revealed five poor metabolizers of CYP2D6. The others were extensive metabolizers. The ratio of dextromethorphan to dextrorphan ranged from 0.01-2.53 in serum and from 0.0007-4.252 in urine. Probit analysis of serum ratios revealed a bimodal distribution with an antimode at 0.126. According to this antimode, control subjects exhibited identical phenotypes and genotypes, whereas patients under paroxetine, moclobemide or metoprolol who had been genotyped as extensive metabolizers were poor metabolizer phenotypes. Administration of tricyclic antidepressants did not change the CYP2D6 phenotype. The serum assay was more rapid and more accurate than the standard urine approach. Therefore the determination of dextromethorphan and metabolites in serum could be advantageous to measure individual CYP2D6 activities in vivo and thus optimize the dosing of drugs metabolized by CYP2D6.

Adult↗

How important is the differentiation between apnea and hypopnea?

Apnea and hypopnea during sleep are often viewed as different expressions of the same sleep-related breathing disorder. In our point of view, both symptoms are two different entities which can occur in the same patient. We discuss the hypothesis that sleep apnea is a disorder associated with recurrent arousals and chronic activation of the sympathetic nervous system, leading to daytime sleepiness and disturbances in the autonomic system. Hypoventilation results from reduced alveolar ventilation and is associated with hypercapnia. In rare cases it is caused by genuine disorders of the breathing center, like Odine's curse. In most cases, hypoventilation is secondary to an underlying disease and a strategy of the body, to avoid respiratory muscle failure. Treatment trials of hypoventilation of the respiratory muscles by stimulating the breathing center failed to be beneficial. However, unloading treatment with long-term oxygen and/or home mechanical ventilation improves arterial blood gases, physical activity and prognosis.

Arousal↗

A new tongue advancement technique for sleep-disordered breathing: side effects and efficacy.

We examined the efficacy and the acceptance of an oral device (SnorEx) causing a forward displacement of the tongue for the treatment of sleep-disordered breathing (SDB). Twenty-three consecutive subjects with SDB were investigated. Noncompliance (NC) of use of the oral appliance was observed in 74% (17 of 23) of the subjects. NC patients were characterized by unacceptable local side effects of the prosthesis, lacking improvement of indicators of daytime well-being, and a missing reduction of the respiratory disturbance index (RDI). The device was tolerated without side effects in 26% (6 of 23) of the subjects. In these compliant (C) subjects the RDI, EDS, and snoring improved significantly (p < 0.05) compared with baseline values. After 6 mo using the device, five of the six C patients were still using it. We conclude that the high rate of noncompliance and the low efficacy of the SnorEx prosthesis preclude large-scale use of this treatment modality in patients with SDB and snoring since the local side effects are the principal cause of NC. No useful predictive parameter of treatment compliance or treatment success was found. Thus, this dental appliance should be prescribed only for selected patients failing other treatment modalities seen by an experienced sleep-disorders specialist.

Dental Prosthesis↗

Comparison of two different modes for noninvasive mechanical ventilation in chronic respiratory failure: volume versus pressure controlled device.

The most commonly used mode of noninvasive mechanical ventilation (NMV) is volume-controlled intermittent positive pressure ventilation (IPPV). Pressure support ventilation has recently become increasingly popular, but its merits have not been clearly defined. In an open, nonrandomized follow-up study, we evaluated two modes of NMV, volume-controlled (IPPV) and pressure-controlled ventilation (PCV) over 6 months in 30 consecutive patients (24 males and 6 females, aged 49 +/- 19 yrs) with chronic respiratory failure (CRF). The baseline assessments comprised both physiological and subjective data. In all cases, nasal IPPV was initially administered for 1 month, followed by a second month of nasal PCV. Thereafter, responders or nonresponders to PCV were defined according to the patients' subjective symptom score and/or the recurrence of hypercapnia. During the IPPV phase, in all but two patients the subjective and objective parameters improved significantly. During the following 1 month PCV phase, stabilization was maintained in 18 patients ("responders"), while 10 patients were defined as "nonresponders". In nonresponders, hypercapnia increased (arterial carbon dioxide tension (Pa,CO2): 5.7 +/- 0.4 to 6.6 +/- 0.5 kPa; p < 0.05) and symptom scores decreased. Compared with responders, nonresponders had a lower mean nocturnal arterial oxygen saturation (Sa,O2) (p < 0.05) and a higher daytime Pa,CO2 (p < 0.05) at baseline. We con clude that the majority of patients suffering from chronic respiratory failure who are initially satisfactorily ventilated with intermittent positive pressure ventilation may also be adequately maintained with pressure-controlled ventilation. However, there is a subgroup with more severe chronic respiratory failure at baseline, in whom pressure-controlled ventilation is inadequate. After 4 weeks of treatment with pressure-controlled ventilation, the subjective scores and the arterial carbon dioxide tension values reliably distinguished between long-term responders and nonresponders to pressure-controlled ventilation.

Adult↗

Evaluation of a movement detector to measure daily activity in patients with chronic lung disease.

This study was designed to evaluate the performance of movement detectors (pedometers) in measuring daily activity of patients with chronic lung disease. Three groups of subjects were studied: group 1: 25 patients with stable nonhypercapnic chronic obstructive pulmonary disease (COPD) (forced expiratory volume in one second (FEV1) = 47+/-9% predicted) studied twice, one month apart; group 2: 25 patients with chronic respiratory failure studied before and three months after nasal nocturnal mechanical ventilation; and group 3: 25 normal healthy subjects studied once. The median level of activity in the healthy subjects (group 3) was three times greater than in either group of patients (groups 1 and 2). Activity levels were not correlated with age, sex or employment status. The repeatability of the activity counts in the nonhypercapnic COPD patients was high (intraclass correlation coefficient=0.94) and in these patients activity correlated significantly with FEV1 (r=0.54, p=0.006). In the respiratory failure patients, daytime arterial carbon dioxide pressure (Pa,CO2) improved following nasal nocturnal mechanical ventilation (NMV) (pre NMV: 8.5+/-1.2 kPa; post NMV: 6.2+/-0.5 kPa), health status improved (p<0.004) and daily movement count doubled (p<0.0001). This increase correlated with change in Pa,CO2 (r-0.53, p=0.006), but not with improved health status. We conclude that motion detectors may provide repeatable measures of daily activity that are related to physiological impairment and improvement following treatment. Activity counts appear to be complementary to estimates of exercise limitation obtained using health questionnaires.

Activities of Daily Living↗

Daytime mechanical ventilation in chronic respiratory insufficiency.

Chronic respiratory insufficiency (CRI) is associated with nocturnal hypoventilation. Treatment with noninvasive mechanical ventilation (NIMV) performed overnight relieves symptoms of hypoventilation and improves daytime blood gases in CRI. In order to test whether the efficacy of NIMV depends on it being applied during sleep, we conducted a prospective case-controlled study comparing daytime mechanical ventilation (dMV) in awake patients with nocturnal mechanical ventilation (nMV) given in equal quantities. We enrolled 34 clinically stable patients (age 56.1+/-12.1 yrs, 20 females, 14 males) with CRI due to restrictive lung and chest wall disorders and neuromuscular disease. Using a prospective case-control design, matched subjects were allocated alternately to dMV and nMV. After 1 month of NIMV there was considerable symptomatic improvement in both dMV and nMV patients. There were no significant differences between groups in the improvement in daytime arterial carbon dioxide tension (Pa,CO2) (dMV from 7.5+/-0.6 to 5.7+/-0.6 kPa; nMV from 7.2+/-0.5 to 5.8+/-0.5 kPa, p<0.0001) and during the unassisted spontaneous night-time ventilation in terms of transcutaneous Pa,CO2 (dMV from 8.4+/-1.2 to 6.6+/-0.7 kPa; nMV from 8.2+/-1.2 to 6.8+/-0.5 kPa, p<0.0001). We conclude that in many respects, when compared to nocturnal mechanical ventilation, daytime mechanical ventilation in awake patients is equally effective at reversing chronic respiratory insufficiency. Since long-term safety issues were not addressed in this study, we recommend that nocturnal mechanical ventilation should remain the modality of choice for noninvasive mechanical ventilation.

Adult↗

[Optical stimulation method (Snore-Stop) and tongue retainer (Snore-Master) without relevance in therapy of obstructive sleep apnea and snoring].

Recently intra- und extraoral devices are increasingly used in order to treat obstructive sleep apnea and snoring. We examined the value of an optically stimulating system ("eye-cover", Snore-Stop) and a tongue-retainer (Snore-Master) as treatment of the obstructive sleep apnoe or snoring. In case of the eye-cover is a microphone integrated, which detects acoustic signals (e.g. snoring). After detection of snoring optical stimuli are generated in front of the eyes. This is intended to induce an arousal of the patient, without awaking him, causing a change of body position and this reduces the snoring or apneas. For the examination of the eye-cover in 26 patients (23 men, 55.6 +/- 10.3 years) polygraphic studies were performed while sleeping one night with the eye-cover and one night without, respectively. Visual analogue scales (VAS) were used in order to measure quality of life and sleep and the adverse effects of the device. To examine the tongue-retainer 14 patients (13 men, aged 52.9 +/- 11.8 years) were measured polygraphically. Again the subjective scores were assessed using the VAS. The principle of the tongue-retainer is to create a hollow space in front of the teeth, in which the tongue is positioned. Fixation of the tongue in this ventral position is thought to enlarge the mesopharyngeal area in order to reduce the upper airway obstruction. For both devices the index of snoring, the apnea-hypopnea-index, the index of desaturation, the mean and minimal SaO2 and SaO2 < 90 % in % of the night did not change significantly. Furthermore the subjective perception of the patients concerning their quality of sleep and life did not change. Moreover, despite of an adequate adaptation-period the use of the tongue-retainer was associated with considerable adverse effects. Neither the eye-cover nor the tongue-retainer could improve the severity of obstructive sleep apnoe or snoring.

Adult↗

[A new portable monitor for long-term cough recording].

Cough is a common symptom of pulmonary diseases. For a number of reasons it would be of interest to have information about the frequency of coughs over a given period of time. So far, the cough recorders which are available are either too expensive or unwieldy. Hence, we developed a cough recorder linked to a portable, commercially available actigraph (about the size of a pack of cigarettes) that records coughing as an acoustic signal and ventral thorax movement. The signals are filtered via a band pass and sampled by a peak detektor with different time constants to separate the impulse character of the cough signal from the background noise level. The cough recorder registers coughing cumulatively over a period of one minute and has a storage time of one week. Since the acoustic signals are essential for the interpretation of the recordings, the analogue circuit was subjected to a separate validation programme. For this purpose, the distinction between active coughs of 10 volunteers (total number of coughs 550) and background noises (male and female voices and other defined noises, total number of noises 336) was tested. The complete assembly was then tested over night on 7 hospitalised patients with chronic cough. An infrared video camera system was used to make a reference recording of the overnight coughing. The results show that nearly every cough of the 10 volunteers was recorded (r = 0.99). 97.1% of the background noise was correctly interpreted. The complete recorder assembly correctly recorded 98.9% of the coughs (total 870) in the 7 patients. 4.8% of the background noise was erroneously registered as coughing. Summing up, it can be said that the portable cough recorder affords accurate recording of coughing over a period of one week, correctly distinguishing coughing from background noise.

Adult↗

[Bronchial hyperreactivity and nCPAP therapy].

In patients with obstructive sleep apnoea (OSA) nCPAP may irritate the mucous membranes of the upper airways. We investigated in this study whether nCPAP can induce bronchial hyperreactivity (BHR). Forty-one patients (33 men, mean age 52.6 years) were treated with nCPAP due to OSA. All of them were tested for BHR with histamine ("pari-provo-Test") before and six weeks after initiation of the nCPAP therapy. Thirty-five of the patients showed BHR neither before nor after the beginning of CPAP. Six patients developed a BHR of moderate degree (PD20: 50-100 micrograms) during the study; four of these six patients were not symptomatic. The two other patients complained about more colds than usual or about noctumal cough. Both of them received inhaled steroids and a moistening system. Nobody of the enrolled patients was obliged to finish CPAP therapy due to BHR. Four patients had already a BHR before nCPAP therapy began. Most of the patients did not acquire a BHR during the first 6 weeks after nCPAP therapy had started. A BHR bronchial may develop, but in the majority it remains without clinical relevance. In patients with a BHR and OSA, the benefits of nCPAP therapy excel the potential adverse effects.

Airway Resistance↗

[Is SnorEx also ApneaEx? A study with a new intra-oral prosthesis as a form of therapy of obstructive sleep apnea syndrome].

UNLABELLED: In recent years different kinds of dental devices have been advocated for treating sleep apnoea. In this study we report on our results with a kind of prosthesis ("Snor-Ex", DEPITA, 29336 Nienhagen) designed to relieve upper airway obstruction in sleep in pulling forward the tongue by a truss pad positioned in the posterior area of the tongue. We performed the study to test the effectiveness of the device in reducing the number of obstructive events. PATIENTS: 23 patients with OSA (22 male, age: 53.7 +/- 8.6 years, Body mass index: 31.1 +/- 3.9 kg/m2, Apnoea index: 33.5 +/- 18.4, Respiratory disturbance index: 45.6 +/- 19.7, mean apnoea duration: 20.4 +/- 4.4 sec) were included. STUDY DESIGN: Before the study was started, polysomnography was performed and the OSA associated symptoms/claims were standardised with the help of visual analogue scales (VAS). The prosthesis were made by the dental laboratory. Between the 28th and 42nd day after beginning with the study the patients had to come to the hospital for control. The effect of the therapy was documented only by a further polysomnography in patients who could sleep for at least 2.5 hours with the prosthesis. The effects of the device on changing OSA-associated symptoms and snoring were reevaluated by the above mentioned VAS. During the control the patients were divided into non-responders (NR) and responders (R) according to the results. RESULTS: The NR prevail in the study with 75% (17/23). They are characterised by inacceptable loco-regional side effects of the prosthesis, missing improvement of the state of daytime wellbeing and constant obstructive events. Only 25% of the patients are R. They locally tolerated the prosthesis, which is the precondition for long-term therapy. The severity of OSA diminished. Snoring also diminished significantly. CONCLUSION: According to our results the insufficient acceptance and the low effectivity of the SnorEx-prosthesis preclude large-scale indication for OSA patients. The prosthesis should not be prescribed without contacting a sleep lab.

Adult↗

[Predictive value of laryngoscopy with reference to the severity of obstructive sleep apnea].

The diagnosis of sleep-related breathing disorders is based primarily upon targeted history-taking and upon night-time polysomnography. Diagnostic measures should be completed by laryngopharyngoscopy (LPS). Frequently in cases of relevant obstructive sleep-related breathing disorders, a collapse of the pharyngeal lumen may be detected already in the waking state: either during spontaneous breathing or through adequate provocation (snoring manoeuvre). Furthermore, endoscopy of the upper airways will yield indirect clues as to nocturnal snoring and possible obstructive apnoeas. Although the predictive value of LPS regarding the degree of obstructive sleep-related breathing disorders seems low compared with polysomnography, it appears reasonable to perform it to exclude further relevant ENT findings. With LPS, local and regional obstacles of the kind of the intended positive pressure ventilation (narrowing of the nasal ducts, septum deviation and hyperplasia of the turbinates) are demonstrable which may warrant surgical correction. LPS, which has a low complication rate, facilitates interdisciplinary cooperation in the care for patients suffering from obstructive sleep-related breathing disorders.

Airway Obstruction↗

[Work of breathing in differentiation of various forms of sleep-related breathing disorders].

BACKGROUND: In contrast to the obstructive sleep apnoea syndrome (OSA) the obesity-hypoventilation syndrome (OHS) is characterised by persistent hypercapnia during the day and predominant hypoventilation during sleep. In this study we wanted to know whether work of breathing (WOB) in a sitting and supine position separates both groups. PATIENTS AND METHODS: OSA population: 20 men, 50.5 +/- 9.2 years, Body Mass Index (BMI: 54.1 +/- 6.9 kg/m2, pO2: 65.6 +/- 6.6 mmHg, pCO2: 40.6 +/- 3.1 mmHg, OHS-group: 14 patients, 13 men age: 53.1 +/- 9.3 years, BMI: 53.1 +/- 9.3 kg/m2, pO2: 51.8 +/- 10.5 mmHg, pCO2: 53.8 +/- 9.2 mmHg. The control group consisted of 10 normal weighted subjects. The intrathoracic pressures were assessed by an oesophageal catheter; at the same time, the minute ventilation (VE) and the breathing frequency (fb) were measured via a pneumotachygraph. The area under the pressure-volume loop was correlated to WOB. After reaching steady state VE, fb, and WOB were determined in sitting and supine position. RESULTS: In the OSA-group the apnoea index (AI) was 48.6 +/- 17.7/h and the respiratory disturbance index (RDI) was 66.3 +/- 19.4/h. The forced expiratory volume (FEV1) was 77.3 +/- 23% pred. and the vital capacity (VC) was 76.3 +/- 18.6% pred.; 7 out of 20 patients suffered from chronic bronchitis. In the OHS-group the AI was 21.5 +/- 19/h and the RDI 44.3 +/- 28.2/h. The majority of OHS patients had an airway obstruction (FEV1: 55.8 +/- 17.5% pred., VC: 58.8 +/- 12.8% pred.); 12 out of 14 patients suffered from chronic bronchitis. Compared to the OSA population WOB in the OHS group was significantly higher both in the sitting (0.67 +/- 0.28 J/I versus 1.04 +/- 0.32 J/I, p < 0.001) and supine positions (1.23 +/- 0.25 J/I versus 1.91 +/- 0.43 J/I, p < 0.001). Compared to the sitting position VE and fb did not change significantly in both groups lying supine. CONCLUSIONS: Compared to the OSA group at the same BMI the WOB of the OHS population was significantly increased in the sitting and supine position. The main reason for these findings may be the increased airway obstruction due to chronic bronchitis. Both populations did not change the breathing patterns during the different positions.

Adult↗