Interobserver agreement on visual field progression in glaucoma: a comparison of methods.

AIM: To examine the level of agreement between clinicians in assessing progressive deterioration in visual field series using two different methods of analysis. METHODS: Each visual field series satisfied the following criteria: more than 19 reliable fields, patient age over 40 years, macular threshold at least 30 dB. The first three fields in each series were excluded to minimise learning effects: the following 16 were studied. Five expert clinicians assessed the progression status of each series using both standard Humphrey printouts and pointwise linear regression (PROGRESSOR). The level of agreement between the clinicians was evaluated using a weighted kappa statistic. RESULTS: A total of 432 tests comprising 27 visual field series of 16 tests each were assessed by the clinicians. The level of agreement on progression status between the clinicians was always higher when they used PROGRESSOR (median kappa = 0.59) than when they used Humphrey printouts (median kappa = 0.32). This was statistically significant (p = 0.006, Wilcoxon matched pairs signed rank sum test). CONCLUSIONS: Agreement between expert clinicians about visual field progression status is poor when standard Humphrey printouts are used, even when the field series studied are long and consist solely of reliable fields. Under these ideal conditions, clinicians agree more closely about patients' visual field progression status when using PROGRESSOR than when inspecting series of Humphrey printouts.

Adult↗

Use of high spatial resolution perimetry to identify scotomata not apparent with conventional perimetry in the nasal field of glaucomatous subjects.

AIM: To examine whether high spatial resolution perimetry (HSRP) could identify fine scale scotomata which may not be apparent with conventional perimetry. The HSRP was performed in the nasal field, as this location is a recognised site for the early occurrence of glaucomatous defects. METHOD: 16 early glaucoma eyes, 17 glaucoma suspect eyes, and 20 age matched healthy control eyes underwent conventional automated perimetry using the 24-2 program of the Humphrey field analyser (HFA) and HSRP. The HSRP was performed in the nasal field by testing 9 x 9 degrees of 100 tested points separated by 1 degree and the results compared with the HFA 24-2 program. RESULTS: Mean HSRP thresholds were significantly abnormal in the suspect and glaucoma eyes, with elevated levels of asymmetry between the superior and inferior nasal field. Overall, 7/17 (41%) suspect eyes (95% confidence interval 5/17 (29%) to 7/17 (41%)) had nasal scotomata on HSRP, although their HFA 24-2 fields failed to identify any defects. In glaucomatous eyes, 15/16 (94%) eyes had HSRP scotomata (95% CI 14/16 (88%) to 15/16 (94%)). In 12 these coexisted with HFA 24-2 defects at the same location, while in three eyes only HSRP identified scotomata in the nasal field. CONCLUSION: HSRP can identify scotoma in glaucomatous eyes in the nasal field which may be missed with the lower spatial resolution of conventional perimetry.

Aged↗

Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry.

AIMS: The development of imaging and measurement techniques has brought the prospect of greater objectivity in the measurement of optic disc features, and therefore better agreement between observers. The purpose of this study was to quantify and compare the variation between observers using two measurement devices. METHODS: Optic disc photographs and images from the Heidelberg retina tomograph (HRT) of 30 eyes of 30 subjects were presented to six observers for analysis, and to one observer on five separate occasions. Agreement between observers was studied by comparing the analysis of each observer with the median result of the other five, and expressed as the mean difference and standard deviation of differences between the observer and the median. Inter- and intraobserver variation was calculated as a coefficient of variation (mean SD/mean x 100). RESULTS: For planimetry, agreement between observers was dependent on observer experience, for the HRT it was independent. Agreement between observers (SD of differences as a percentage of the median) for optic disc area was 4.0% to 7.2% (planimetry) and 3.3% to 6.0% (HRT), for neuroretinal rim area it was 10.8% to 21.0% (planimetry) and 5.2% to 9.6% (HRT). The mean interobserver coefficient of variation for optic disc area was 8.1% (planimetry) and 4.4% (HRT), for neuroretinal rim area it was 16.3% (planimetry) and 8.1% (HRT), and (HRT only) for rim volume was 16.3%, and reference height 9.1%. HRT variability was greater for the software version 1.11 reference plane than for version 1.10. The intraobserver coefficient of variation for optic disc area was 1.5% (planimetry) and 2.4% (HRT), for neuroretinal rim area it was 4.0% (planimetry) and 4.5% (HRT). CONCLUSIONS: Variation between observers is greatly reduced by the HRT when compared with planimetry. However, levels of variation, which may be clinically significant, remain for variables that depend on the subjective drawing of the disc margin.

Glaucoma↗