PubMed Health⌕ Search

Biomedical subjects

D Keating

Publications and source records attributed to D Keating.

42 records · Page 3Linked to original sources

Comparison of repeatability of the multifocal electroretinogram and Humphrey perimeter.

Functional mapping of the retina by multifocal electroretinographic recordings is now possible. We compared the normal range, repeatability and response topography of this new technique with conventional static Humphrey perimetry to assess its suitability in clinical practice. The multifocal technique was performed on 60 age-matched controls. Measures of repeatability and reproducibility were obtained. Results were then compared with those obtained from a customized perimetry test. In both tests the coefficients of repeatability were found to decrease with eccentricity. The inherent measurement variation between techniques was comparable. Overall system variation indicates that the technique could be a useful tool at the clinical level.

Computer Graphics↗

The effect of filter bandwidth on the multifocal electroretinogram.

The effect of filter bandwith on the multifocal electroretinogram was assessed by means of theoretical calculation, electronic simulation and real multifocal electroretinogram recordings. Waveform distortion by high-pass filtering on simulated square waves, normal electroretinogram waveforms and negative electroretinogram waveforms was demonstrated. The theory of the effect of differentiation on electroretinogram waveform shape by electronic filtering indicates that little effect would be observed by changing the input filter cut-off for normal electroretinographic waveform shapes. However, negative electroretinogram waveforms are differentiated when the high-pass filter setting is increased. The differentiation effect artificially recreates a positive component that could be mistaken as a b-wave component. To eliminate this effect when recording multifocal electroretinograms, a high-pass filter setting of less than 1 Hz should be used to preserve the true electroretinographic waveform shape.

Computer Simulation↗

MR-guided localization of suspected breast lesions detected exclusively by postcontrast MRI.

OBJECTIVE: We describe and evaluate a preoperative MRI localization procedure for suspected breast lesions. MATERIALS AND METHODS: Fourteen consecutive patients underwent MR localization of suspected breast lesions discovered with contrast-enhanced MRI but not detected by conventional mammography or ultrasound. In each case diagnostic MRI was repeated after the application of special skin markers. A non-magnetic wire was subsequently inserted into the breast and a second MRI performed to document the position of the wire tip relative to the lesion. RESULTS: The procedure was successful in all 14 patients, enabling excision of the lesion and allowing histological diagnoses. CONCLUSION: We found the described procedure to be quite useful.

Adult↗

A versatile speech output communication aid.

A portable, battery-powered communication aid with speech output, which can be operated by patients with limited finger control, is described. The device is sufficiently versatile to try out different methods of selection of words or phrases in the search for an acceptable, portable communication aid for the speech impaired.

Communication Devices for People with Disabilities↗

Optical coherence tomography in the diagnosis of subclinical serous detachment of the macula secondary to a choroidal nevus.

We present a case in which optical coherence tomography (OCT) aided in the diagnosis of subretinal fluid (SRF) secondary to a choroidal nevus. A patient with a raised lesion above the left optic disc and distorted central vision was referred to our unit because of suspected choroidal melanoma. Fundus fluorescein angiography and slit-lamp investigation did not indicate any areas of SRF; however, OCT showed serous detachment in the macular area. The lesion was treated with laser photocoagulation and, when reviewed at four weeks post-treatment, repeat OCT scans showed that the area of SRF had cleared. In this case OCT was able to detect a subclinical serous detachment in the macula. This may have important implications in the monitoring of patients with small suspicious lesions.

Aged↗

The development of a comprehensive stroke programme in the acute hospital.

Stroke is the third leading cause of death and an important cause of hospital admissions and long term disability. The incidence of stroke is estimated at 200 per 100,000 of the population, Dublin has approximately 2,400 new strokes per annum. In 1989 a comprehensive stroke programme was introduced in St Vincent's Hospital. The aim was to provide patients with a coordinated approach to rehabilitation. A study of the programme was conducted in 1993 by detailed chart review. 129 patients with a clinical diagnosis of stroke were referred to the programme during a 12 month period. 27.13% were under age 65 and 72.87% were over 65 years, 18% died and 44.2% were discharged home, independently mobile. The study findings suggest that the comprehensive stroke programme in St Vincent's Hospital represents a feasible model of care in the acute general hospital setting.

Acute Disease↗