PubMed Health⌕ Search

Biomedical subjects

D Kenyon

Publications and source records attributed to D Kenyon.

7 recordsLinked to original sources

Decreased internalisation of erbB1 mutants in lung cancer is linked with a mechanism conferring sensitivity to gefitinib.

A majority of gefitinib (IRESSA)-responsive tumours in non-small cell lung cancer have been found to carry mutations in ErbB1. Previously, it has been observed that internalisation-deficient ErbB1 receptors are strong drivers of oncogenesis. Using a computational model of ErbB1 trafficking and signalling, it is found that a deficiency in ErbB1 internalisation is sufficient to explain the observed signalling phenotype of these gefitinib-responsive ErbB1 mutants in lung cancer cell lines. Experimental tests confirm that gefitinib-sensitive cell lines with and without ErbB1 mutations exhibit markedly slower internalisation rates than gefitinib-insensitive cell lines. Moreover, the computational model demonstrates that reduced ErbB1 internalisation rates are mechanistically linked to upregulated AKT signalling. Experimentally it is confirmed that impaired internalisation of ErbB1 is associated with increased AKT activity, which can be blocked by gefitinib. On the basis of these experimental and computational results, it is surmised that gefitinib sensitivity is a marker of a reliance on AKT signalling for cell survival that may be brought about by impaired ErbB1 internalisation.

Antineoplastic Agents↗

Drug delivery performance of the mometasone furoate dry powder inhaler.

The mometasone furoate dry powder inhaler (MF-DPI) is a multiple-dose, breath-actuated inhaler that uses agglomerates of micronized MF and lactose. In vitro analyses evaluated dose uniformity, variability, and particle size distribution of the MF-DPI. Tests of first, middle, and end doses from 10 inhalers each of the 200-microg MF/inhalation and 400-microg MF/inhalation dose sizes found that delivered doses (doses emitted from the inhaler) ranged from 91% to 112% of claimed doses for all tested DPIs. The mean MF doses delivered at 28.3 L/min were 100% and 94% of the doses delivered at 60 L/min for the 200-microg and 400-microg dose sizes, respectively; the relative standard deviation of doses was < or = 6.1% within this range of inhalation rates. At a flow rate of 60 L/min, the mean delivered doses, compared to claimed doses for inspiration times of 1-3 sec, were 102-104% for the 200-microg dose size and 98.8-102% for the 400-microg dose size. The mean cumulative fraction of dose delivered at 60 L/min for 2 sec which consisted of particles of <6.5 microm in diameter was 39.9% (+/-2.5 SD; n = 9) for the 200-microg dose size and 35.6% (+/-3.4 SD; n = 9) for the 400-microg dose size. All MF-DPI inhalers tested were well within U.S. and European compendial standards and regulatory guidelines for dose uniformity. An appropriate and reproducible fraction of the delivered dose was within the optimal particle size range for therapeutic effectiveness.

Administration, Inhalation↗

A passive method of disposal of expired anaesthetic gases.

A passive method for the disposal of waste anaesthetic gases is described. The resistance characteristics of the collector valve, the balancing device and the disposal system were studied. It was found that the resistances offered by the conduction channels and the terminal exhaust valve were extremely low. The collector valves were found to be responsible for most of the expiratory resistance. Swabs taken from various components of the system showed that these were contaminated mainly with commensals and non-pathogenic organisms.

Air Pollution↗