A rational approach to crossmatching blood for elective surgery.

A group-and-screen system was introduced for selected surgical procedures to improve the cost-effectiveness of the hospital blood transfusion service. The mean crossmatch-transfusion ratio for eleven procedures was 11.1 but fell to 3.3 after the change. The overall crossmatch-transfusion ratio in the hospital improved from 2.7 to 2.2 (p less than 0.001) and blood wastage by expiry fell from 12% to 5% (p less than 0.02). The mean age of blood being transfused also improved slightly from 12.3 days to 10.4 days (p less than 0.001). No problems have arisen from the group-and-screen system to date. It has led to improvement in the efficiency and cost-effectiveness of the hospital blood bank and resulted in fresher blood being transfused.

ABO Blood-Group System↗

In-vitro synthesis of an anti-BI cold agglutinin complicating a case of lymphoma.

A woman of 47 with lymphocytic lymphoma was found to have a high-titer cold autoagglutinin of anit-BI specificity. Her group B erythrocytes autoagglutinated of anti-BI specificity. Her group B erythrocytes autoagglutinated in vitro and the direct antiglobulin reaction was positive, but she had no symptom of cold intolerance, no evidence of hemolysis, and she could receive transfusions of compatible group O erythrocytes. In addition, evidence for synthesis of the autoantibody by the lymphoma cells was obtained by short-term bone-marrow culture.

ABO Blood-Group System↗