Control of interstitial thermal coagulation: comparative evaluation of microwave and ultrasound applicators.

This study presents a comparative evaluation of the control of heating and thermal coagulation with microwave (MW) and ultrasound (US) interstitial applicators. Helical coil MW antennas (17 mm and 25 mm length radiating antennae) were tested using an external implant catheter (2.2 mm o.d.) with water-cooling. US applicators with tubular transducers (2.2 and 2.5 mm o.d., 10 mm length, single-element and 3-element) were utilized with a direct-coupled configuration and internal water-cooling. Measurements of E-field distributions (for MW) and acoustic beam distributions (for US) were used to characterize the applicator energy output. Thermal performance was evaluated through multiple heating trials in vitro (bovine liver) and in vivo (porcine thigh muscle and liver) at varied levels of applied power (20-40 W for microwave, 15-35 W for ultrasound) and heating times (0.5-5 min). Axial temperature distributions in the tissue were recorded during heating, and dimensions of the resulting lesions of thermal coagulation were measured. Both MW and US applicators produced large volumes of tissue coagulation ranging from 8 to 20 cm3 with singular heating times of 5 min. Radial depth of lesions for both MW and US applicators increased with heating duration and power levels, though US produced notably larger lesion diameters (30-42 mm for US vs 18-26 mm for MW, 5 min heating). Characteristic differences between the applicators were observed in axial energy distribution, tissue temperatures, and thermal lesion shapes. MW lesions increased significantly in axial dimensions (beyond the active applicator length) as applied power level and/or heating duration was increased, and lesion shapes were generally not uniform. US provided greater control and uniformity of heating, with energy deposition and axial extent of thermal lesions corresponding to the length of the active transducer(s). The improved ability to control the extent of thermal coagulation demonstrated by the US applicators provides greater potential to target a specific region of tissue.

Animals↗

Ultrasound applicators with internal water-cooling for high-powered interstitial thermal therapy.

Internal water-cooling of direct-coupled ultrasound (US) applicators for interstitial thermal therapy (hyperthermia and coagulative thermal therapy) was investigated. Implantable applicators were constructed using tubular US sources (360 angular acoustic emittance, approximately 7 MHz) of 10 mm length and 1.5, 1.8, 2.2, and 2.5 mm outer diameter (OD). Directional applicators were also constructed using 2.2 mm OD tubes sectored to provide active acoustic sectors of 90 degrees and 200 degrees. A water-cooling mechanism was integrated within the inner lumen of the applicator to remove heat from the inner transducer surface. High levels of convective heat transfer (2100-3800 W/m2K) were measured for practical water flow rates of 20-80 mL/min. Comparative acoustic measurements demonstrated that internal water-cooling did not significantly degrade the acoustic intensity or beam distribution of the US transducers. Water-cooling allowed substantially higher levels of applied electrical power (> 45 W) than previous designs (with air-cooling or no cooling), without detriment to the applicators. High-temperature heating trials performed with these applicators in vivo (porcine liver and thigh muscle) and in vitro (bovine liver) showed improved thermal penetration and coagulation. Radial depth of coagulation from the applicator surface ranged from 12 to 20 mm for 1-5 min of sonication with 28-W applied power. Higher powers (41 W) demonstrated increased coagulation depths (approximately 9 mm) at shorter times (15 s). Thermal lesion dimensions (angular and axial expanse) produced with directional applicators were controlled and directed, and corresponded to the active zone of the transducer. These characteristic lesion shapes were also generally unchanged with different sonication times and power, and were found to be consistent with previous coagulation studies using air-cooled applicators. The implementation of water-cooling is a significant advance for the application of ultrasound interstitial thermal therapy (USITT), providing greater treatment volumes, shorter treatment times, and the potential for treatment of highly perfused tissue with shaped lesions.

Acoustics↗

Angular directivity of thermal coagulation using air-cooled direct-coupled interstitial ultrasound applicators.

The performance characteristics and thermal coagulation of tissue produced by directional air-cooled, direct-coupled interstitial ultrasound (US) applicators were evaluated. Prototype applicators (2.2 mm o.d.) were constructed using cylindrical transducers sectored into angular active zones of 90 degrees, 200 degrees, 270 degrees, and 360 degrees. Acoustic characterization of the applicators showed the beam output to be angularly directed from the active sector of the transducer and collimated within the axial extent. Empirical determination of the average convective heat transfer coefficient, resulting from airflow cooling the inner surface of the transducer, showed significantly high levels of transfer (> 700 W m(-2) degrees C(-1)) with a flow rate of 5.6 L min(-1). Thermal performance of the applicators was characterized through high temperature heating in vivo (porcine thigh muscle, 11 trials) and in vitro (bovine liver, 46 trials). Results demonstrated directional coagulation of tissue, with good correlation between the angular extent of the lesions and the active acoustic sector. Radial depth of coagulation with a 200 degrees applicator extended 8-17 mm, with a heating time of 1-10 min, respectively. Angular and axial lesion shape remained similar over the course of 1-10 min heating trials. Implementation of air-cooling within direct-coupled interstitial US applicators provided enhanced directivity of heating in angular and axial dimensions, and significantly increased the power handling and radial depth of tissue coagulation.

Air↗

Air-cooling of direct-coupled ultrasound applicators for interstitial hyperthermia and thermal coagulation.

The feasibility of using air-cooling to improve the thermal penetration of direct-coupled interstitial ultrasound (US) applicators was investigated using biothermal simulations, bench experiments, phantom testing, and in vivo thermal dosimetry. Two applicator configurations using tubular US transducers were constructed and tested. The first design, intended for simultaneous thermobrachy-therapy, utilizes a 2.5 mm OD transducer with a central lumen to accommodate a radiation source from remote afterloaders. The second applicator consists of a 2.2 mm OD transducer designed for coagulative thermal therapy. Both designs provide cooling of the inner transducer surface by the counterflow of chilled air or CO2 gas through the annulus of the enclosed applicator. The average convective heat transfer (ha) associated with each applicator was determined empirically from curve-fits of radial steady-state temperatures measured in a tissue-mimicking phantom. High levels of convective heat transfer (ha > 500 W m-2 degrees C-1) were demonstrated in both designs at relatively low flow rates (< 5 L min-1). Transient and steady-state radial heating profiles were also measured in vivo (pig thigh muscle) with and without cooling. The therapeutic radius for hyperthermia (41-45 degrees C) was extended from 5-6 mm (without cooling) to 11-19 mm with air-cooling (4.8 L min-1, airflow 10 degrees C), effectively doubling and tripling the thermal penetration in vivo. Similar improvements were demonstrated at higher temperatures with the thermal coagulation applicator. Biothermal simulations, which modeled the physical, thermal, and acoustic parameters of the air-cooled applicator and surrounding tissue, were also used to investigate potential improvements in heating patterns. The simulated radial heating profiles with transducer cooling demonstrated significantly enhanced thermal penetration over the experimental range of convective transfer, and also agreed with in vivo results. These theoretical and experimental results clearly show air-cooling controls the transducer surface temperature, significantly increases thermal penetration, and produces a greater treatment volume for direct-coupled US applicators in hyperthermia and thermal coagulation.

Acoustics↗

Effect of preparation techniques on mixing of additives in intravenous fluids in nonrigid containers.

It has been observed that the procedures of some hospitals do not require any mixing after drugs are added to intravenous bags. Previous studies have shown that mixing often is incomplete in the absence of specific mixing procedures. It has been asserted that mixing is effected by normal handling of bags, and that mixing is sufficient if drug is added to "bottom up" bags, which are then inverted. In this study the extent to which mixing occurred on addition of KCl solution or water to intravenous bags as a function of bag and needle position, additive, speed of addition, and bag handling procedure was determined. Also determined was the extent to which mixing occurred spontaneously. Most important, we determined the effect of incomplete mixing on the concentration of drug actually delivered from the bags. It was concluded that mixing is critically dependent on many factors, and that an effective technique to achieve complete mixing is essential to assure homogenous solutions. The most effective method of mixing solutions in plastic infusion bags is to grasp the bag by its two ends and rapidly invert it twice. This "double inversion" mixing technique, a maneuver requiring only 2 seconds, assures complete mixing of intravenous solutions.

Drug Combinations↗

Osmotic strength, osmolality, and osmolarity.

The confusion that often exists between osmolality and osmolarity is discussed, and the clinical importance of careful distinction between these terms is emphasized. The clinical effects of abnormal osmotic strength of parenteral solutions, methods of determining osmolality and osmolarity, and the practical applications of these concepts are reviewed. Although osmolality can be determined experimentally (whereas osmolarity cannot) it is difficult or impossible to use osmolality in calculations associated with the extemporaneous preparation and administration of fluids such as i.v. admixtures. Hence, there is a need in many cases for product labels to state both osmolality and osmolarity.

Chemistry, Pharmaceutical↗

Combination of transurethral and interstitial ultrasound applicators for high-temperature prostate thermal therapy.

The purpose of this study was to determine the feasibility of using a transurethral ultrasound applicator in combination with implantable ultrasound applicators for inducing thermal coagulation and necrosis of localized cancer lesions or benign disease within the prostate gland. The potential to treat target zones in the anterior and lateral portions of the prostate with the angularly directive transurethral applicator, while simultaneously treating regions of extracapsular extension and zones in the posterior prostate with the directive implantable applicators in combination with a rectal cooling bolus, is evaluated. Biothermal computer simulations, acoustic characterizations, and in vivo thermal dosimetry experiments with canine prostates were used to evaluate the performance of each applicator type and combinations thereof. Simulations have demonstrated that transurethral applicators with 180-270 degrees acoustic active zones can direct therapeutic heating patterns to the anterior and lateral prostate, implantable needles can isolate heating to the posterior gland while avoiding rectal tissue, and that the combination of applicators can be used to produce conformal heating to the whole gland. Single implantable applicators (1.8 mm OD x 10 mm long, approximately 180 degrees active sector, approximately 7 MHz, direct-coupled type) produced directional thermal lesions within in vivo prostate, with temperatures >50 degrees C extending more than 10 mm radially after 10-15 min. Combination of interstitial applicators (1-2) and a transurethral applicator (3-2.5 mm OD x 6 mm long, approximately 180 degrees active sector, 6.8 MHz, 6 mm OD delivery catheter) produced conforming temperature distributions (48-85 degrees C) and zones of acute thermal damage within 15 min. The preliminary results of this investigation demonstrate that implantable directional ultrasound applicators, in combination with a transurethral ultrasound applicator, have the potential to provide thermal coagulation and necrosis of small or large regions within the prostate gland, while sparing thermally sensitive rectal tissue.

Acoustics↗