PubMed Health⌕ Search

Biomedical subjects

D L Kopperdahl

Publications and source records attributed to D L Kopperdahl.

5 recordsLinked to original sources

Biomechanical consequences of an isolated overload on the human vertebral body.

The biomechanical consequences of an isolated overload to the vertebral body may play a role in the etiology of vertebral fracture. In this context, we quantified residual strains and reductions in stiffness and ultimate load when vertebral bodies were loaded to various levels beyond the elastic regimen and related these properties to the externally applied strain and bone density. Twenty-three vertebral bodies (T11-L4, from 23 cadavers aged 20-90 years) were loaded once in compression to a randomized nominal strain level between 0.37 and 4.5%, unloaded, and then reloaded to 10% strain. Residual strains of up to 1.36% developed on unloading and depended on the applied strain (r2=0.85) but not on density (p = 0.25). Percentage reductions in stiffness and ultimate load of up to 83.7 and 52.5%, respectively, depended on both applied strain (r2 = 0.90 and r2 = 0.32, respectively) and density (r2 = 0.23 and r2 = 0.22, respectively). Development of residual strains is indicative of permanent deformations, whereas percentage reductions in stiffness are direct measures of effective mechanical damage. These results therefore demonstrate that substantial mechanical damage-which is not visible from radiographs-can develop in the vertebral body after isolated overloads, as well as subtle but significant permanent deformations. This behavior is similar to that observed previously for cylindrical cores of trabecular bone. Taken together, these findings indicate that the damage behavior of the lumbar and lower thoracic vertebral body is dominated by the trabecular bone and may be an important factor in the etiology of vertebral fracture.

Adult↗

Mechanical behavior of human trabecular bone after overloading.

With the etiology of osteoporotic fractures as motivation, the goal of this study was to characterize the mechanical behavior of human trabecular bone after overloading. Specifically, we quantified the reductions in modulus and strength and the development of residual deformations and determined the dependence of these parameters on the applied strain and apparent density. Forty cylindrical specimens of human L1 vertebral trabecular bone were destructively loaded in compression at 0.5% strain per second to strains of up to 3.0% and then immediately unloaded to zero stress and reloaded. (An ancillary experiment on more readily available bovine bone had been performed previously to develop this testing protocol.) In general, the reloading stress-strain curve had a short initial nonlinear region with a tangent modulus similar to Young's modulus. This was followed by an approximately linear region spanning to 0.7% strain, with a reduced residual modulus. The reloading curve always approached the extrapolated envelope of the original loading curve. Percent modulus reduction (between Young's and residual), a quantitative measure of mechanical damage, ranged from 5.2 to 91.0% across the specimens. It increased with increasing plastic strain (r2 = 0.97) but was not related to modulus or apparent density. Percent strength reduction, in the range of 3.6-63.8%, increased with increasing plastic strain (r2 = 0.61) and decreasing apparent density (r2 = 0.23). The residual strains of up to 1.05% depended strongly on applied strain (r2 = 0.96). Statistical comparisons with previous data for bovine tibial bone lend substantial generality to these trends and provide an envelope of expected behavior for other sites. In addition to providing a basis for biomechanical analysis of the effects of damage in trabecular bone at the organ level, these findings support the concept that occasional overloads may increase the risk of fracture by substantially degrading the mechanical properties of the underlying trabecular bone.

Adult↗

Localized damage in vertebral bone is most detrimental in regions of high strain energy density.

It was hypothesized that damage to bone tissue would be most detrimental to the structural integrity of the vertebral body if it occurred in regions with high strain energy density, and not necessarily in regions of high or low trabecular bone apparent density, or in a particular anatomic location. The reduction in stiffness due to localized damage was computed in 16 finite element models of 10-mm-thick human vertebral sections. Statistical analyses were performed to determine which characteristic at the damage location--strain energy density, apparent density, or anatomic location--best predicted the corresponding stiffness reduction. There was a strong positive correlation between regional strain energy density and structural stiffness reduction in all 16 vertebral sections for damage in the trabecular centrum (p < 0.05, r2 = 0.43-0.93). By contrast, regional apparent density showed a significant negative correlation to stiffness reduction in only four of the sixteen bones (p < 0.05, r2 = 0.47-0.58). While damage in different anatomic locations did lead to different reductions in stiffness (p < 0.0001, ANOVA), no single location was consistently the most critical location for damage. Thus, knowledge of the characteristics of bone that determine strain energy density distributions can provide an understanding of how damage reduces whole bone mechanical properties. A patient-specific finite element model displaying a map of strain energy density can help optimize surgical planning and reinforcement of bone in individuals with high fracture risk.

Adult↗

Yield strain behavior of trabecular bone.

If bone adapts to maintain constant strains and if on-axis yield strains in trabecular bone are independent of apparent density, adaptive remodeling in trabecular bone should maintain a constant safety factor (yield strain/functional strain) during habitual loading. To test the hypothesis that yield strains are indeed independent of density, compressive (n = 22) and tensile (n = 22) yield strains were measured without end-artifacts for low density (0.18 +/- 0.04 g cm(-3)) human vertebral trabecular bone specimens. Loads were applied in the superior-inferior direction along the principal trabecular orientation. These 'on-axis' yield strains were compared to those measured previously for high-density (0.51 +/- 0.06 g cm(-3)) bovine tibial trabecular bone (n = 44). Mean (+/- S.D.) yield strains for the human bone were 0.78 +/- 0.04% in tension and 0.84 +/- 0.06% in compression; corresponding values for the bovine bone were 0.78 +/- 0.04 and 1.09 +/- 0.12%, respectively. Tensile yield strains were independent of the apparent density across the entire density range (human p = 0.40, bovine p = 0.64, pooled p = 0.97). By contrast, compressive yield strains were linearly correlated with apparent density for the human bone (p < 0.001) and the pooled data (p < 0.001), and a suggestive trend existed for the bovine data (p = 0.06). These results refute the hypothesis that on-axis yield strains for trabecular bone are independent of density for compressive loading, although values may appear constant over a narrow density range. On-axis tensile yield strains appear to be independent of both apparent density and anatomic site.

Adaptation, Physiological↗

Systematic and random errors in compression testing of trabecular bone.

We sought to quantify the systematic and random errors associated with end-artifacts in the platens compression test for trabecular bone. Our hypothesis was that while errors may depend on anatomic site, they do not depend on apparent density and therefore have substantial random components. Trabecular bone specimens were first tested nondestructively using newly developed accurate protocols and then were tested again using the platens compression test. Percentage differences in modulus between the techniques (bovine proximal tibia [n = 18] and humerus [n = 17] and human lumbar spine, [n = 9]) were in the range of 4-86%. These differences did not depend on anatomic site (p = 0.21) and were only weakly dependent on apparent density and specimen aspect ratio (r2 < 0.10). The mean percentage difference in modulus was 32.6%, representing the systematic component of the end-artifact error. Neglecting the minor variations explained by density and specimen size (approximately 10%), an upper bound on the random error from end-artifacts in this experiment was taken as the SD of the modulus difference (+/-18.2%). Based on a synthesis of data taken from this study and from the literature, we concluded that the systematic underestimation error in the platens compression test can be only approximated and is in the range of 20-40%; the substantial random error (+/-12.5%) confounds correction, particularly when the sample size is small. These errors should be considered when interpreting results from the platens test, and more accurate testing techniques should be used when such errors are not acceptable.

Animals↗