A quantitative assessment of the addition of MRI to CT-based, 3-D treatment planning of brain tumors.

Quantitative 3-D volumetric comparisons were made of composite CT-MRI macroscopic and microscopic tumor and target volumes to their independently defined constituents. Volumetric comparisons were also made between volumes derived from coronal and axial MRI data sets, and between CT and MRI volumes redefined at a repeat session in comparison to their original definitions. The degree of 3-D dose coverage obtained from use of CT data only or MRI data only in terms of coverage of composite CT-MRI volumes was also analyzed. On average, MRI defined larger volumes as well as a greater share of composite CT-MRI volumes. On average, increases in block margin on the order of 0.5 cm would have ensured coverage of volumes derived from use of both imaging modalities had only MRI data been used. However, the degree of inter-observer variation in volume definition is on the order of the magnitude of differences in volume definition seen between the modalities, and the question of which imaging modality best describes tumor volumes remains unanswered until detailed histologic studies are performed. Given that tumor volumes independently apparent on CT and MRI have equal validity, composite CT-MRI input should be considered for planning to ensure precise dose coverage for conformal treatments.

Astrocytoma

Potential improvement in the results of irradiation for prostate carcinoma using improved dose distribution.

Results for radiation treatment of prostate carcinoma indicate that nearly one-third of Stage C patients fail locally. This number will likely increase as occult failures are discovered by monitoring serum prostate specific antigen levels. Thus, there is need for techniques that would increase the local control of prostatic carcinoma. Using cross-sectional imaging and 3-dimensional treatment planning, dose distributions for photon irradiation can be created that conform more closely to the shape of the prostate and seminal vesicles, sparing additional dose to portions of bladder and rectum. A dose escalation trial is underway to investigate whether these techniques will lead to increased local control without unacceptable increases in bladder and rectal complications. While zero local failures is probably an unattainable goal, reduction in local failure in prostate cancer would likely increase the overall cure rate in this disease.

Humans

The clinical utility of magnetic resonance imaging in 3-dimensional treatment planning of brain neoplasms.

Results of the clinical experience gained since 1986 in the treatment planning of patients with brain neoplasms through integration of magnetic resonance imaging (MRI) into computerized tomography (CT)-based, three-dimensional treatment planning are presented. Data from MRI can now be fully registered with CT data using appropriate three-dimensional coordinate transformations allowing: (a) display of MRI defined structures on CT images; (b) treatment planning of composite CT-MRI volumes; (c) dose display on either CT or MRI images. Treatment planning with non-coplanar beam arrangements is also facilitated by MRI because of direct acquisition of information in multiple, orthogonal planes. The advantages of this integration of information are especially evident in certain situations, for example, low grade astrocytomas with indistinct CT margins, tumors with margins obscured by bone artifact on CT scan. Target definitions have repeatedly been altered based on MRI detected abnormalities not visualized on CT scans. Regions of gadolinium enhancement on MRI T1-weighted scans can be compared to the contrast-enhancing CT tumor volumes, while abnormalities detected on MRI T2-weighted scans are the counterpart of CT-defined edema. Generally, MRI markedly increased the apparent macroscopic tumor volume from that seen on contrast-CT alone. However, CT tumor information was also necessary as it defined abnormalities not always perceptible with MRI (on average, 19% of composite CT-MRI volume seen on CT only). In all, the integration of MRI data with CT information has been found to be practical, and often necessary, for the three-dimensional treatment of brain neoplasms.

Astrocytoma

Three-dimensional tumor dosimetry for hepatic yttrium-90-microsphere therapy.

The nonuniformity of dose deposition for hepatic 90Y-microsphere therapy is believed to play an important role in the relative sparing of normal liver tissues. To help study this issue, three-dimensional dose calculations have been performed for the VX2 tumor model in the rabbit treated with hepatic arterial administration of 90Y-glass microspheres (90Y-MS). Colored, nonactivated spheres of similar size to 90Y-MS were injected into the hepatic artery to mimic the treatment deposition of 90Y-MS. Sample blocks of treated liver were serially sectioned (200 microns thickness), fixed and photographed showing the position of the colored microspheres. The microsphere positions were digitized into a three-dimensional treatment planning system, and three-dimensional dose calculations were performed. A 2-mm diameter liver tumor nodule receiving 15 times more microspheres than nearby normal liver resulted in tumor-to-normal-tissue (TNT) calculated dose ratios of 2.6 (average dose) and 1.9 (minimum dose). The nonuniform microsphere distribution resulted in a dose gradient over the nodule with a minimum value which was less than one half the average dose. The relative dose deposition in the vicinity of the tumor nodule does not fully reconcile the known liver tolerance dose derived from uniform irradiation with the large calculated average doses tolerated with this type of therapy.

Animals

Technical considerations in the use of 3-D beam arrangements in the abdomen.

The practical utilization of 3-D treatment planning to reduce doses to normal tissues in the abdomen is illustrated for irradiation of hepatic masses using fields with central axes rotated out of the transverse plane. The beams were arranged to go through the minimum amount of normal liver tissue, while exiting above or below a kidney. Although these beam arrangements were not coplanar with standard transverse body sections, they were designed for dose delivery through use of standard Megavoltage equipment. The planning process for these techniques illustrates the need for and use of several tools usually associated with 3-D treatment planning systems. Beam's eye-view planning with perspective display of the relevant anatomy in the projective beam geometry is required for designing the placement of focused blocks for these oblique fields. Three-dimensional volumetric dose calculations are required to evaluate dose distributions. Additionally, port-film-type radiographs, digitally reconstructed from the CT dataset, are found to be useful in understanding the correctness of simulation and verification films. The reduction in dose to normal tissues over that achievable using standard plans with beams entering the patient at right angles to the central axis of the body is illustrated using dose-volume histograms. These techniques have allowed the initiation of a radiation dose escalation protocol for tumors involving the liver and porta hepatis.

Abdomen

Three-dimensional treatment planning of astrocytomas: a dosimetric study of cerebral irradiation.

To demonstrate that 3-dimensional planning is both practical and applicable to the treatment of high-grade astrocytomas, 50 patients over a 2-year period have received cerebral irradiation delivered in focussed, non-axial techniques employing from 2 to 5 beams. Astrocytomas have been planned using rapid, practical incorporation of CT data to define appropriate tumor volumes. Tumor + 3.0 cm and tumor + 1.5 cm volumes have been treated to conventional doses of 4500 cGy and 5940 cGy, respectively, using beam orientations that maximally spared normal remaining parenchyma. Analyses of 3-dimensionally calculated plans have been performed using integral dose-volume histograms (DVH) to help select treatment techniques. Using identical CT-based volumetric data as input for generation of Beam's Eye View (BEV) designed blocks, DVH curves demonstrate dosimetric advantages of non-axial techniques over conventional parallel-opposed orientations. Assessment of the non-axial techniques in selected cases indicates that uniform target volume coverage could be maintained with a typical reduction of 30% in the total amount of brain tissue treated to high dose (95% isodose line).

Astrocytoma

Treatment planning issues related to prostate movement in response to differential filling of the rectum and bladder.

Conventional stimulation for patients with localized prostatic carcinoma often includes opacification of the dose limiting adjacent normal tissues. However, CT-based treatment planning is performed with the bladder and the rectum naturally filled or emptied. These latter conditions more closely approximate those in place at treatment Comparison of these CT-based treatment plans to simulator films taken with the rectum and bladder opacified yielded indirect evidence of movement of the prostate gland by 0.5 cm or more in 31 of 50 consecutive patients. The range of motion was 0 to 2 cm with an average of 0.5 cm (1.0 cm in the 31 patients). Six additional patients (five with local recurrence following I-125 seed implantation) were analyzed separately using CT scans. Registered CT images (3 mm slices) taken with the rectum and bladder full and/or empty provided direct evidence of prostate movement in 3 of the 6 patients. The dosimetric consequences of this movement are demonstrated using 3-dimensional dose distributions.

Computer Simulation

The use of CT-based 3-D anatomical modeling in the design of customized perineal templates for interstitial gynecologic implants.

A system for preplanning interstitial treatment of gynecologic malignancies with a CT-based 3-dimensional planning system is presented. The preplan produces a custom template design that optimizes catheter placement. The procedure begins with a CT scan with a vaginal cylinder and blank template in place. Contours of the anatomic structures of interest, cylinder, and template are entered into the system, and 3-D surfaces are generated. The first view evaluated is oriented in a "cylinder's-eye view," which shows the path of the catheters placed parallel to the cylinder. In most cases this path to the tumor is obstructed by the pubic bones and bladder. By rotating the view posteriorly, the catheters can travel under the symphysis and bladder to the tumor. Once the optimum angle for visualization of the tumor has been determined, an array of catheters is designed to optimize the dose to the tumor. This array includes the special distribution in the oblique plane as well as the depth of insertion for each catheter. The design is then used in drilling the appropriate guide holes in the template. Orthogonal film dosimetry as well as CT verification of source placement will be compared to the preplan distribution.

Brachytherapy

Full integration of the beam's eye view concept into computerized treatment planning.

A complete set of beam's eye view (BEV) and beam portal design features have been integrated into a computerized 3-dimensional radiotherapy treatment planning system. Among the features implemented is the ability to mix BEV graphics with gray-scale images such as simulator and verification radiographs, and digital reconstructed radiographs. Image processing techniques have been developed to both enhance verification images and to detect radiation field boundaries. These portal simulation and presentation techniques are being used clinically to design and verify radiation fields with manual or automatically-designed field shaping blocks. The ability to perform computer dose calculations for planes which are parallel or perpendicular to a specified beam's central axis is available and this feature has also proven useful for treatment plan evaluation and optimization. Finally, direct comparison of computer-generated portal images with actual simulation and verification radiographs is also possible. These techniques allow the direct integration of "CT-directed treatment planning" with block design, simulator films and port films, and other Beam's Eye View-type displays.

Computer Simulation

Boost treatment of the prostate using shaped, fixed fields.

Using a CT-based, 3-D treatment planning system and Beam's Eye-View (BEV) displays, shaped fixed-field techniques have been developed for external beam boost treatment of Stage C carcinoma of the prostate. The basic technique comprises three sets of opposing beams (laterals and +/- 45 degrees with respect to the lateral) into a 6-field arrangement. Target volumes together with bladder and rectal wall volumes are outlined on axial CT slices and combined to form 3-D volumes. For each field, an interactive BEV display is produced showing the target volume in its correct 3-D geometrical perspective and an auto-block routine is used to design focused blocks which conform to that volume. Full 3-D volume calculations computed for those plans on 17 patients were analyzed along with similar calculations for more traditional unblocked 4-field box and bilateral arc techniques. Compared to the 95% isodose volume for the 6-field conformational technique, traditional open beam full target coverage techniques typically produce high dose volumes which cover up to five times as much uninvolved tissue. Dose volume histograms illustrate that typically half as much bladder and rectal tissue is treated to high dose using the conformational boost techniques. From the dosimetric perspective of sparing normal tissues, shaped fixed-field boost techniques are shown to be clearly superior to traditional full coverage bilateral arc techniques. Smaller 8 cm X 8 cm arc techniques are shown to be quantitatively unacceptable for treatment of this advanced stage disease, as they typically misses 20-35% of the target volume.

Humans

A CT-compatible version of the Fletcher system intracavitary applicator: clinical application and 3-dimensional treatment planning.

A new acrylic version of the familiar Fletcher intracavitary applicator, the Ann Arbor (AA) applicator, has been developed. This new device eliminates the problem of "streak" artifacts on CT images, but unlike other plastic applicators the ability to shield portions of the bladder and rectum is retained through the use of tungsten alloy shields which are afterloaded with the radioactive sources. To minimize changes in placement geometry and to take advantage of the wide clinical experience with the Fletcher system, the new applicator nearly duplicates the physical dimensions of the Fletcher applicator. With the Ann Arbor applicator in place, dummy sources are easier to locate on standard radiographic simulations. CT scans are free of artifact and provide clear, detailed visualizations of cross-sectional anatomy. The new applicator thus allows CT images to be used to their potential in evaluating crucial anatomic relationships and in performing 3-D dosimetry with dose volume analysis. Using a treatment planning system with 3-D capabilities, solid surface graphic display of applicator, cervix, rectum, bladder, and treatment isodose volume has been performed. In addition, dose volume histograms can be generated to obtain precise measurements of the volume of cervix, rectum, or bladder receiving specified doses.

Brachytherapy

Comparison of automated and manual shielding block fabrication.

This work reports the results of a study comparing computer controlled and manual shielding block cutting. The general problems inherent in automated block cutting have been identified and minimized. A system whose accuracy is sufficient for clinical applications has been developed. The relative accuracy of our automated system versus experienced technician controlled cutting was investigated. In general, it is found that automated cutting is somewhat faster and more accurate than manual cutting for very large fields, but that the reverse is true for most smaller fields. The relative cost effectiveness of automated cutting is dependent on the percentage of computer designed blocks which are generated in the clinical setting. At the present time, the traditional manual method is still favored.

Humans

The influence of lung density corrections on treatment planning for primary breast cancer.

Primary breast cancer is generally treated with opposed radiation beams oriented tangentially with respect to the breast. This technique attempts to minimize the dose to the lung and other normal tissues, while at the same time producing a uniform dose distribution throughout the irradiated breast. Although a part of the lung is always included in the tangential breast fields, the effect of this low density tissue on the dose distribution is rarely taken into account. In the present work, the effect of lung density correction on the dose distribution resulting from tangential breast fields is analyzed. Treatment plans for a series of 34 patients treated for breast cancer have been performed using CT data. To study the effect of density corrections on the tangential field treatment plans for these patients, eight separate treatment plans for each patient have been optimized. For each of four photon energies (60Co, and 4, 6, and 10 MV X rays), treatment plans have been optimized for each patient when density correction is employed, and when unit density is assumed. Four additional dose calculations have been obtained for each patient corresponding to use of the unit density plan, but with density corrections employed in the calculation. The effects that density correction has on the wedge angles used, on the maximum dose ("hot spot") for each of several cross-sectional cuts, on the prescription isodose level which is chosen for each plan, and on homogeneity of the dose distribution over the target volume are all analyzed for the above described plans.

Breast Neoplasms

From manual to 3-D computerized treatment planning for 125-I stereotactic brain implants.

Aspects of planning for the treatment of high grade primary or recurrent brain tumors with stereotactically placed catheters afterloaded with high activity 125-I seeds are discussed. At our institution, planning has evolved from a simple manual process, which assumed geometric symmetry, through a more advanced manual process, that took advantage of certain mechanical properties of the stereotactic frame used, into a sophisticated, computerized planning approach that includes optimization of the source distribution and 3-D displays. Use of the simple manual method is limited to the rare situations where target volumes are quite regular in shape. The advanced manual method provides some customization for irregularly shaped volumes, but is slow and tedious to implement. The interactive, computerized approach permits identification of target volumes directly on CT slices, reconstructions in arbitrary planes, and optimization of catheter placement, source separation along each catheter, and selection of source strengths from an available inventory. A multi-format display feature which includes a probe's eye view perspective is provided to aid in planning. Integral dose-volume histograms for the target volume point out the advantages in using sophisticated, 3-D, computerized planning systems for these implants.

Brachytherapy

Recent advances in radiotherapy treatment planning.

The need for accurate treatment planning in radiation therapy arose as more powerful radiation technology became available. Computers now make it possible to use increasingly sophisticated dose calculation methods. Over the last two decades, modern imaging modalities, faster computer hardware, advanced graphics techniques, and new calculational algorithms have made it easier to plan radiotherapy treatment. The prospect is bright for continued improvement during the next several years. Tumor localization will become more precise using three-dimensional displays of integrated radiographic imaging data, as described in this article.

Computer Graphics

Integration of magnetic resonance imaging into radiation therapy treatment planning: I. Technical considerations.

This paper presents the results of a feasibility study specifically addressing the technical and operational difficulties in making quantitative use of Magnetic Resonance Imaging (MRI) in radiation therapy treatment planning (RTTP). Selected radiotherapy patients have been studied with both CT and MRI as part of the treatment planning process. Both sets of images, along with mechanically-obtained external contour and simulator film data, are entered into the treatment planning system. All of the capabilities of the fully three dimensional planning system U-MPlan are available to both the CT and MRI images, in which any image can be used as the backdrop for interactive beam positioning, beam portal simulation, and dose distribution displays for external beam and brachytherapy applications in both 2- and 3-dimensionally-oriented displays. The study has shown that to use MRI data for RTTP, one must (a) use careful patient positioning and marking, (b) transfer information from CT to MRI and vice versa, (c) determine the geometrical consistency between the CT and MR data sets, (d) investigate the unwarping of distorted MR images, and (e) have the ability to use non-axial images for determination of beam treatment technique, dose calculations, and plan evaluation.

Brain Neoplasms

A computerized three-dimensional treatment planning system utilizing interactive colour graphics.

A new computerized radiation treatment planning system has been developed to aid in three-dimensional treatment planning. Using interactive colour graphics in conjunction with a DPD 11/45 computer, the system can take multiple transverse contours and construct a perspective display of the treatment region showing organ surfaces as well as cross-sectional contours. With interactively selected orientations, the display allows easy perception of the relative positioning of the treatment volume and neighbouring anatomy. For external beam treatment planning, interactive computer simulation is used to select diaphragm sizes which best conform to the target area while avoiding sensitive structures. Dose calculations for the selected beams are carried out on multiple transverse planes. The calculational planes and surfaces are displayed in perspective with radiation dosage displayed in an interactively manipulated colour display. Altogether the system provides an easy assessment of the volume to be irradiated, interactive selection of optimal arrangements of treatment fields and a means for visualizing and evaluating the resulting dose distributions.

Color

Three dimensional CT of central lung tumors.

Three-dimensional computed tomography (CT) reconstructions and conventional CT were compared with surgical/pathological findings in seven patients with central lung tumors, in order to assess accuracy in predicting the lobectomy/pneumonectomy decision. Although conventional CT surpassed 3D CT in diagnosing bronchial tumor invasion, 3D CT appeared to be better for central arterial invasion. Despite problems due to motion effects, partial volume averaging and the time consuming nature of the reconstruction process, 3D CT is probably useful in this setting and promises to have similar applications throughout the body.

Adenocarcinoma