PubMed Health⌕ Search

Biomedical subjects

D L Steffens

Publications and source records attributed to D L Steffens.

14 recordsLinked to original sources

Sequence analysis of mitochondrial DNA hypervariable regions using infrared fluorescence detection.

The non-coding region of the mitochondrial genome provides an attractive target for human forensic identification studies. Two hypervariable (HV) regions, each approximately 250-350 bp in length, contain the majority of mitochondrial DNA (mtDNA) sequence variability among different individuals. Various approaches to determine mtDNA sequence were evaluated utilizing highly sensitive infrared (IR) fluorescence detection. HV regions were amplified either together or separately and cycle-sequenced using a Thermo Sequenase protocol. An M13 universal primer sequence tail covalently attached to the 5' terminus of an amplification primer facilitated electrophoretic analysis and direct sequencing of the amplification products using IR detection.

DNA Primers↗

Multiplex amplification of STR loci with gender alleles using infrared fluorescence detection.

The analysis of short tandem repeat (STR) polymorphisms has proven extremely useful for gene mapping, paternity testing, and forensic analysis. Several commercial products are currently available for performing amplification and analysis of STRs. We have adapted Promega Geneprint Systems for use with a high sensitivity infrared (IR) fluorescent automated DNA sequencer. IR-labeled amplification products are generated by including a small quantity of IR-labeled dATP in the reaction. Several Geneprint STR loci can be multiplexed together with the amelogenin sex identification locus in a single amplification reaction. We have successfully amplified up to five Geneprint STR loci together with the amelogenin locus thus improving the throughput of analysis. Purified genomic DNA as well as simulated forensic samples have been utilized for these multiplex amplifications.

Alleles↗

Ligation mediated fluorescent labeling of DNA sequencing primers.

Automated DNA sequencing utilizing fluorescently labeled primers is a proven methodology for generating quality sequence data. However, for directed primer walking strategies this necessitates synthesis and labeling of a unique primer for each sequencing reaction. Here, we describe a rapid ligation-based method of generating labeled sequencing primers. An unlabeled 5'-phosphorylated sequencing primer is ligated to a fluorescent oligonucleotide by use of a bridge primer which is complementary to portions of the previous two oligonucleotides, thus aligning them properly for ligation. The resulting fluorescent hybrid primer can be utilized directly in cycle sequencing reactions without any prior purification.

Chromosome Walking↗

Infrared fluorescent detection of PCR amplified gender identifying alleles.

An automated DNA sequencer utilizing high sensitivity infrared (IR) fluorescence technology together with Polymerase Chain Reaction (PCR) methodology was used to detect several sex differentiating loci on the X and Y chromosomes from various samples often encountered in forensic case work. Amplifications of the X-Y homologous amelogenin gene, the alpha-satellite (alphoid) repeat sequences and the X and Y chromosome zinc finger protein genes ZFX and ZFY (ZFX/ZFY) were performed. DNA extracted from various forensic specimens was amplified using either Taq, Tth or ThermoSequenase. Multiplexing using primers for all three loci in one reaction tube was achieved using Tth and ThermoSequenase. Two IR labeling strategies for detection of PCR products were utilized. In the first strategy, one of the PCR primers contained a 19-base extension at its 5' end identical to an IR-labeled universal M13 Forward (-29) primer which was included in the amplification reactions. During PCR the tailed primer generates sequence complementary to the M13 primer which subsequently primes the initial amplification products, thereby generating IR-labeled PCR products. In the second strategy, dATP labeled with an IR dye (IR-dATP) was included in the amplification reaction. During amplification IR-dATP was utilized by the polymerase and incorporated into the synthesized DNA, thus resulting in IR-labeled PCR products. X and Y specific bands were readily detected using both labeling methodologies. Amplified products were electrophoretically resolved using denaturing Long-Ranger gels and detected with an automated detection system using IR laser irradiation. A separation distance of 15 cm allowed run times of less than 2 h from sample loading to detection. Because the gels could be run more than once, at least 120 samples (2 loads x 60 samples/load) can be typed using a single gel.

Alleles↗

Producing STR locus patterns from bloodstains and other forensic samples using an infrared fluorescent automated DNA sequencer.

Short tandem repeat (STR) analysis is increasingly being used in forensic case analysis because of the large number of STR loci in the human genome and their highly polymorphic nature. An automated DNA sequencer using high sensitivity infrared (IR) fluorescence technology was used to detect STR allele patterns from simulated forensic samples. The amplification strategy used a 19 base pair extension on the 5' end of one of the PCR primers. This sequence is identical to the sequence of a universal M13 Forward sequencing primer which is included in the amplification reaction. Allelic bands were detected by incorporation of the M13 primer-fluorescent dye conjugate into PCR products thus eliminating the need for direct conjugation of fluorescent dye to individual STR primers. By using an IR-based automated DNA sequencer and Tth DNA polymerase, polymorphic STR alleles were detected on-line rapidly and efficiently from bloodstains using only a high temperature incubation to extract DNA from blood cells. Five STR loci were also amplified using Chelex extracted DNA from simulated forensic samples. Multiplexing of three primer pairs in a single PCR mixture for amplification was accomplished using Taq polymerase. This system combines IR fluorescence chemistry and laser technology thus eliminating the need for radioactivity and the gel handling required with silver staining and fluor detection systems. Real-time detection permits immediate visualization of the data and STR alleles are displayed as familiar autoradiogramlike images that can be analyzed by computer. By loading a 64 lane gel twice and multiplexing with three primer pairs, forensic scientists can type at least three loci from 120 samples in one day.

Alleles↗

An infrared fluorescent dATP for labeling DNA.

Near-infrared fluorescence provides a nonradioactive method of detection with high sensitivity and low background. An infrared fluorophore has been attached covalently to the nucleotide deoxyadenosine triphosphate (dATP) to provide a reagent for enzymatic labeling of various types of DNA molecules and for facilitating their detection with an automated DNA sequencing and analysis system. DNA sequencing reaction products can be labeled internally by performing limited polymerization utilizing infrared-labeled dATP (IR-dATP) as the sole source of adenine deoxynucleotide prior to a dideoxy-specific termination reaction. PCR products can be labeled fluorescently by the addition of limited quantities of IR-dATP to the amplification reaction. This latter strategy has been utilized for detection of short tandem repeat polymorphisms (STRPs) which are useful for gene mapping, genetic diagnostics, forensic analysis, and paternity testing. Restriction fragments can be labeled also by fill-in reactions of appropriate 5' overhangs. Diminutive amounts of such fluorescently labeled DNA molecules can be visualized rapidly and conveniently using infrared detection technology.

Adenosine Triphosphate↗

Sequencing two DNA templates in five channels by digital compression.

By applying algebraic coding methods to the Sanger dideoxynucleotide procedure, DNA sequences of two templates can be determined simultaneously in only five reactions and data channels. A 5:2 data compression is accomplished by instantaneous source coding of nucleotide sequence pairs into one set of 5-bit block codes. A general algebraic expression, 2n-1 > or = 4f, describes conditions under which f DNA templates can be sequenced using n channels. Such compression sequencing is accurate and efficient, as demonstrated by manual 35S autoradiographic detection and automated on-line analysis using fluorescent-labeled primers. Symmetric 5:2 compression is especially useful when comparing two closely related sequences.

Automation↗

Cloning and expression of a human 14-3-3 protein mediating phospholipolysis. Identification of an arachidonoyl-enzyme intermediate during catalysis.

The major phospholipase A2 activity in sheep platelets is mediated by at least three chromatographically resolvable isoforms of a 30-kDa dimeric polypeptide which are responsive to physiologic increments in calcium ion and possess a dramatic substrate selectivity (Loeb, L. A., and Gross, R. W. (1986) J. Biol. Chem. 261, 10467-10470). Herein, we describe the cloning and expression of the human equivalent of one such isoform and demonstrate that it catalyzes the cleavage of the sn-2 fatty acid of choline and ethanolamine glycerophospholipids through the formation of a stable acyl-enzyme intermediate. Transesterification of the sn-2 acyl group of phosphatidylcholine to the recombinant 30-kDa polypeptide is over 50-fold selective for arachidonic acid, is augmented by calcium ion, and results in the formation of an arachidonoyl-thioester intermediate. Homology analysis demonstrated that the polypeptide mediating this transesterification is one member of a family of proteins collectively designated as 14-3-3 proteins. These results demonstrate that at least one intracellular mammalian phospholipase A2 employs a catalytic strategy distinct from that utilized by extracellular phospholipases A2 (i.e. formation of an acyl-enzyme intermediate by nucleophilic attack versus activation of a water molecule) and that arachidonic acid in endogenous phospholipid storage depots can, in principle, be sequentially transferred through an acyl-enzyme intermediate without the prior obligatory release of free arachidonic acid.

14-3-3 Proteins↗

Continuous, on-line DNA sequencing using a versatile infrared laser scanner/electrophoresis apparatus.

A new apparatus for continuously detecting fluorescently labeled DNA fragments is based on infrared fluorescence technology. This technology combines state-of-the-art developments in chemistry, laser technology, and detection, while achieving improved reliability, sensitivity, and flexibility for applications including DNA sequencing. DNA molecules labeled with a novel infrared fluorophore are detected during electrophoresis using a scanning infrared fluorescence microscope. The microscope consists of a laser diode for exciting the fluorophore and a silicon avalanche photodiode for detecting the infrared emission. Optimum conditions for detection and throughput are obtained by adjusting electrophoresis, scanning and imaging parameters. Typical DNA sequencing runs (test templates) allow identification of over 500 bases per sample with greater than 99% accuracy.

Base Sequence↗

Infectious and non-infectious mutants of cauliflower mosaic virus DNA.

Mutants of cauliflower mosaic virus (CaMV), generated in vitro by modification of recombinant DNA plasmids containing the viral genome, either retained the ability to induce disease symptoms on turnip plants, produced less severe symptoms or failed to induce symptoms. Wild-type symptoms were produced by a variant CaMV DNA of the Cabbage S isolate that had 4 bp in open reading frame (ORF) III replaced with a 16 bp sequence. Less severe symptoms, due to a delay in symptom appearance relative to inoculation with wild-type DNA, were induced by a mutant with a frameshift mutation in ORF II (pSA103). CaMV DNA, recovered from plants infected with pSA103, contained a second mutation which restored the original translation reading frame. Nucleic acid hybridization to 'squishes' of leaf tissue from plants that had been inoculated with mutant DNAs that included DNAs modified in each of the six major ORFs of CaMV DNA revealed that only those plants that appeared diseased had detectable CaMV nucleic acid in uninoculated leaves. Replicated CaMV DNA was also not detected in non-encapsidated and virion DNA fractions from inoculated leaves of non-diseased plants.

Base Sequence↗

Sequencing of cloned DNA using bacteriophage lambda gt11 templates.

A procedure for isolating and directly sequencing recombinant bacteriophage lambda gt11 DNA templates is described. Approximately 250-300 bases of sequence can be obtained directly from the lambda gt11 template, eliminating the need for subcloning prior to dideoxynucleotide sequencing of clones.

Bacteriophage lambda↗