PubMed Health⌕ Search

Biomedical subjects

D Labarre

Publications and source records attributed to D Labarre.

At least 19 recordsLinked to original sources

Determining the microbiological criteria for lot rejection from the performance objective or food safety objective.

The Microbiological Criteria (MC) is a set of parameters used to determine whether a specific lot of food is acceptable or not. These parameters are the microbial test protocol and its sensitivity, the confidence level that an unacceptable lot will be detected, the number of samples to be taken and the number of positive samples that are allowed before rejecting the lot. Determining the microbiological criteria begins with knowledge of the distribution of contamination from samples within a lot, particularly within a lot that is just at the unacceptable level of the microbial hazard. The just unacceptable lot can be defined by the Food Safety Objective (FSO) or Performance Objectives (PO), the small fraction of samples that can exceed these values and the standard deviation of the samples from the lot. With this information, a microbial test protocol is chosen to have a sensitivity level that would detect between approximately 15% and 45% of the samples. A confidence level for the MC and the number of positive samples that would be acceptable (c value which is usually zero) are also chosen. With this information the number of samples (n) required can be calculated. A critical factor in setting the microbiological criteria is the sensitivity of the microbiological test (m value). The sample size (weight) and sampling procedure can affect the standard deviation of the samples, particularly foods with non-homogeneous distribution and low numbers of microorganisms. Sampling, sample preparation and analytical procedures that reduce the variation between the samples will affect the choice of m value and maximum lot mean that meets the MC.

Colony Count, Microbial↗

Periodate oxidation of sodium alginate in water and in ethanol-water mixture: a comparative study.

Periodate oxidation of sodium alginate in aqueous solution as well as a dispersion in 1:1 ethanol-water was examined. The oxidation proceeded smoothly in both media, and the kinetics of oxidation was surprisingly similar. Polymer cleavage was observed in both media, but it was extensive in ethanol-water. The weight-average molar mass (Mw) of the oxidized product obtained from aqueous solution showed a gradual decrease with increase in the periodate concentration, whereas, except for very high periodate equivalent, the change in Mw was not reflected with increase in concentration of periodate in ethanol-water. The oxidized alginate obtained from the ethanol-water mixture was found to be more efficient in crosslinking proteins such as gelatin, leading to hydrogels. Oxidation of a dispersion has the advantage of generating large quantities of the oxidized alginate in higher yield with one reaction using less solvent.

Alginates↗

A new generation of polymer nanoparticles for drug delivery.

One of the main interests of using polymer nanoparticles as drug carrier systems is to control the delivery of the drugs including their biodistribution. During the last decade, it was clearly demonstrated that surface properties of nanoparticles were the key factor which determined the in vivo fate of such a carrier. Thus, the purpose of this work was to develop a new method which allows the easy fabrication of nanoparticles with versatile surface properties using polysaccharides. This preparation was based on the use of a redox radical polymerization reaction applied for the first time to the emulsion polymerization of alkylcyanoacrylates in aqueous continuous media. The dispersion of nanoparticles was very stable. The nanoparticle surfaces were coated with polysaccharides and their characteristics can be modulated by the type and the molecular weight of the polysaccharides used during the synthesis. Interestingly the biological properties of the polysaccharide immobilized on the nanoparticle surface can be preserved opening very interesting perspectives for such nanoparticles. This method also offers a new strategy for the design of modular biomimetic nanoparticles as drug carrier systems with multiple functions. One of the applications considered in this work was to use these nanoparticles coupled with haemoglobin as an oxygen carrier.

Complement System Proteins↗

Relationship between complement activation, cellular uptake and surface physicochemical aspects of novel PEG-modified nanocapsules.

The aim of our work was to examine the relationship between modifications of the surface of nanocapsules (NC) by adsorption or covalent grafting of poly(ethylene oxide) (PEG), and changes in their phospholipid (PL) content on complement activation (C3 cleavage) and on uptake by macrophages. The physicochemical characterization of the NC included an investigation of their properties, such as surface charge, size, hydrophilicity, morphology and homogeneity. This is the first time that such properties have been correlated with biological interactions for NC, a novel carrier system with a structure more complex than nanospheres. C3 crossed immunoelectrophoresis revealed the reduced activation for NC with longer PEG chain and higher density, although all formulations induced C3 cleavage to a lesser or greater extent. NC bearing PEG covalently bound to the surface were weaker activators of complement than plain PLA [poly(D,L-lactide)] NC or nanospheres (NS). Furthermore, the fluorescent/confocal microscopy of J774A1 cells in contact with NC reveal a dramatically reduced interaction with PEG-bearing NC. However, the way in which PEG was attached (covalent or adsorbed) seemed to affect the mechanism of uptake. Taken together, these results suggest that the low level of protein binding to NC covered with a high density of 20kDa PEG chains is likely to be due to the steric barriers surrounding these particles, which prevents protein adsorption and reduces their interaction with macrophages.

Adsorption↗

Reduction of the uptake by a macrophagic cell line of nanoparticles bearing heparin or dextran covalently bound to poly(methyl methacrylate).

Amphiphilic and fluorescent covalently labelled core-shell nanoparticles based on poly(methyl methacrylate) (PMMA), were prepared by random copolymerisation of N-Vinyl carbazole (NVC) with MMA, initiated on polysaccharidic radicals, yielding diblock copolymers of either dextran-P(MMA-NVC) (Nanodex* particles), or heparin-P(MMA-NVC) (Nanohep* particles). Nanoparticles made from random copolymers of P(MMA-NVC) (PMMA*) were used as controls. The interactions between particles and a J774A1 murine macrophage-like cell line were quantified by direct measurement of the cell-associated fluorescence. The association with the cells occurred within 30 min. Nanodex* and Nanohep* showed considerably less association than the control PMMA* particles. Some of the particle uptake could be attributed to phagocytosis, but more than 50% of the cell-associated fluorescence persisted at low temperature or in the presence of cytochalasin B. The results suggest that both the adsorption and the internalisation processes can be inhibited by the presence of the polysaccharide chains. In conclusion, these results confirm that nanoparticles prepared with heparin or dextran chains on their surface, probably in a brush-like configuration, show "stealth" properties in vitro as had previously been observed in vivo. If this biomimetic approach can also be applied to biodegradable polymers, these systems would provide at least an alternative to PEG-modified particles as long-circulating drug carriers systems or imaging agents.

Animals↗

Preparation and characterization of nanoparticles bearing heparin or dextran covalently-linked to poly(methyl methacrylate).

Nanoparticles have been obtained directly in aqueous media, from amphiphilic copolymers synthesized by radical polymerization of methyl methacrylate (MMA) initiated by Ce(IV) ions in the presence of heparin or dextran. The reaction conditions under which the copolymers spontaneously formed nanoparticles depended on the type of polysaccharide and on the concentrations of the reagents. Fluorescent nanoparticles containing N-vinyl carbazole (NVC), covalently linked to PMMA, were also prepared by random copolymerization of MMA and NVC in similar polymerization systems. The non-fluorescent nanoparticle suspensions were stable for several months without using surfactant. The fluorescent particles were larger and less stable then the unlabelled ones. Since all the particles are monodisperse, and in the submicron range, they can be used as models of drug carriers; the covalently-linked fluorescent species allowing them to be followed in vivo. The average molecular weights of the PMMA blocks of the copolymers and of oxidized heparin and dextran were determined by viscometry and/or gel permeation chromatography. The antithrombic activity of oxidized heparin was measured. The results show that the polysaccharide chains were cleaved by Ce(IV) in aqueous nitric acid, resulting in formation of block copolymers made of one or two blocks of PMMA linked to the ends of one polysaccharide block. Taken together, the results suggest that the particles were organized with the polysaccharidic moieties on the surface of the particles and the more hydrophobic PMMA or P(MMA-co-NVC) in the core, in a brush-like structure. This should confer 'stealth' properties to such particles.

Anticoagulants↗

Thrombosis of angiographic catheters in humans: experimental study.

One of the major problems in the use of catheters is their thrombogenicity since the embolization of clots near the central nervous system or the coronary arteries can cause permanent damage. Catheter thrombogenicity was evaluated in humans during angiographic procedures by their tendency to become occluded. Characterization of catheters was achieved using roughness measurements, FTIR with ATR, DSC and ESCA. The catheters were 5 commercially available catheters, made mainly of polyethylene, Pebax or polyamide sterilized and ready for clinical use. Thirty-one patients due to have an angiographic procedure and with normal blood and hemodynamic parameters were included in the study. The 50 cm catheter test sample was inserted through an introducer into the femoral artery at the beginning of an angiographic procedure. The outcoming blood flow rate (BFR) was continuously monitored by a special computerized device for 15 min or until the total amount of blood reached 30 ml. The angiographic procedure was then normally resumed. DSC and FTIR showed results consistent with the expected composition of catheters. ESCA results showed very high Si/C ratios and could not be explained in all instances. Occlusion of the catheters occurred in 44% of the cases and the average time to obtain occlusion was 8.5 min (3-15 min). Values of the decrease rate of BFR in ml/min2 allowed separation of the catheters into 3 groups of low, medium and high thrombogenicity. However, occlusion occurred at least one time for each type of catheter. Blood volume and BFR curves vs. time allowed the determination of 3 main types of thrombotic behavior: type I shows no significant reduction of BFR; type II shows a progressive decrease in flow rate; type III is much less frequent and shows an abrupt decrease of BFR either quickly followed by a compensatory increase and resuming of a steady flow or by abrupt occlusion. In type II curves the pattern of occlusion follows a classical diffusion model because the Peclet number is greater than 1 and then the classical Higbie solution for diffusion could be used. The most thrombogenic material was the smoothest. There was no correlation between surface chemical composition and thrombogenicity. However, catheters that were based on PE appeared less thrombogenic than PA catheters in this study.

Angiography↗

Interactions of nanoparticles bearing heparin or dextran covalently bound to poly(methyl methacrylate) with the complement system.

The efficient uptake of injected nanoparticles by cells of the mononuclear phagocyte system (MPS) limits the development of long-circulating colloidal drug carriers. The complement system plays a major role in the opsonization and recognition processes of foreign materials. Since heparin is an inhibitor of complement activation, nanoparticles bearing heparin covalently bound to poly(methyl methacrylate) (PMMA) have been prepared and their interactions with complement evaluated. The particles retained the complement-inhibiting properties of soluble heparin. Nanoparticles bearing covalently bound dextran instead of heparin were weak activators of complement as compared with crosslinked dextran (Sephadex) or bare PMMA nanoparticles. In addition to the specific activity of bound heparin, the protective effect of both polysaccharides is hypothesized to be due to the presence of a dense brush-like layer on the surface of the particles. Such properties are expected to reduce the uptake by MPS in vivo.

Complement Activation↗

Long-circulating nanoparticles bearing heparin or dextran covalently bound to poly(methyl methacrylate).

PURPOSE: In a biomimetic approach to the development of drug carriers escaping early capture by phagocytes, nanoparticles made of amphiphilic copolymers of either heparin or dextran and methyl methacrylate were evaluated relative to their in vivo blood circulation time. They were compared to bare PMMA nanoparticles. METHODS: Owing to the fluorescent properties of the covalently attached N-vinyl carbazole, the particles could be detected directly in mouse plasma. Samples were drawn at different time intervals and fluorescence was recorded. RESULTS: After an initial phase of elimination from the blood with a half-life of 5 h, the remaining heparin nanoparticles circulated for more than 48 h and were still detectable in the plasma at 72 h. Dextran nanoparticles were also eliminated very slowly over 48 h. Bare poly (methyl methacrylate) nanoparticles were found to have a half-life of only 3 min. CONCLUSIONS: Both types of nanoparticles proved to be long-circulating. The potent capacity for opsonisation of the poly(methyl methacrylate) core were hidden by the protective effect of either polysaccharide, probably due to a dense brush-like structure. In the case of heparin nanoparticles, the "stealth" effect was probably increased by its inhibiting properties against complement activation.

Animals↗

Complement consumption by poly(ethylene glycol) in different conformations chemically coupled to poly(isobutyl 2-cyanoacrylate) nanoparticles.

There is an increasing interest to develop injectable drug polymeric carriers not recognizable by the body as foreign particles and eliminated very quickly from the bloodstream. A polyethylene glycol (PEG)-coating onto injectable particles showed to reduce either protein adsorption and complement consumption, as a function of the PEG density. In this work we compared the complement rejecting ability of PEG in different conformations coupled to polyisobutylcyanoacrylate (PIBCA) nanoparticles, through the analysis of the residual hemolytic capacity of the human serum after contact with the particles. Nanoparticles were formed by chemical coupling of PEG during emulsion/polymerization of isobutylcyanoacrylate (IBCA). Nanoparticles characterization included an investigation of their surface properties, such as hydrophilicity and conformational mobility of the PEG chains grafted on the nanoparticles surface, and PEG total content. The polymerization kinetics of IBCA in presence of PEG or MePEG were also studied. Complement consumption was observed to be very sensitive to the number of particles in contact with human serum, as well as to the PEG conformation, suggesting PEG configuration could affect the particle exposed surface.

Complement System Proteins↗

Interactions of poly(lactic acid) and poly(lactic acid-co-ethylene oxide) nanoparticles with the plasma factors of the coagulation system.

When surfactant-stabilized biodegradable poly(lactic acid) (PLA) particles are injected into rats, the rate of clearance from blood is fast. The rate can be strongly reduced by using particles made from diblock copolymers of PLA and poly(ethylene oxide) (PLA-PEO), resulting in an increased duration of contact with the components of the coagulation system. Thus, possible adverse effects such as activation of the coagulation cascade could occur. In this paper, the interactions of surfactant-stabilized PLA and PLA-PEO nanoparticle suspensions with the plasma factors of the coagulation system are presented. PLA suspensions stabilized by sodium cholate (PLA-Ch) interact with thrombin, factor V and calcium ions. Formation of complexes and aggregates is induced by addition of calcium ions to PLA-Ch suspensions in the presence or in the absence of plasma. On the contrary, PLA-PEO suspensions are remarkably inert towards the coagulation factors and calcium ions, even when cholate is present. Steric repulsion owing to the high surface density of PEO is sufficient to avoid strong interations with the proteins and formation of aggregates between particles.

Blood Coagulation↗

Effect of PEO surface density on long-circulating PLA-PEO nanoparticles which are very low complement activators.

The rapid uptake of injected nanoparticles by cells of the mononuclear phagocytes system (MPS) is a major obstacle when a long blood circulation time is needed. Whereas nanoparticles made from PLA and stabilized by surfactants (PLA-F68) are rapidly phagocytized, the rate of phagocytosis is strongly reduced in case of nanoparticles made from a diblock copolymer (PLA-PEO). Because of the role of the complement system in opsonization, this difference of phagocytosis was hypothesized to be related to this system. An important complement consumption was obtained in 5 min in the presence of PLA-F68 particles. In the presence of a higher surface area of PLA-PEO particles possessing a high PEO surface density, the consumption remained very low. When the average PEO surface density was decreased on such particles below a given threshold, a fast and strong complement consumption occurred again. These experimental data support the concept of steric repulsion towards proteins, by surfaces covered with terminally attached PEO chains and emphasize the prime importance of PEO surface density in such an effect. The major, but probably not exclusive, role of complement as an opsonin capable of inducing a fast phagocytosis by MPS should be taken into account concerning the in vitro evaluation of nanoparticles as candidates for a long blood circulation.

Biocompatible Materials↗

Heparin-like functionalized polymer surfaces: discrimination between catalytic and adsorption processes during the course of thrombin inhibition.

Thrombus formation on blood-contacting artificial surfaces is a major problem. Antithrombogenic polymer surfaces have been obtained either by heparin binding, or by grafting sulphonate and/or amino acid sulphonamide groups on insoluble polystyrene. In addition to their capacity to adsorb thrombin, such surfaces were shown to be able to catalyse its inhibition by antithrombin III (AT), i.e. they are endowed with heparin-like activity. The results were mainly obtained by using clotting assays. In many cases, delineating adsorption and catalytic processes by such assays is not possible when evaluating anticoagulant polymer surfaces. To overcome this problem, the kinetics of thrombin adsorption and inhibitions by AT and heparin cofactor II (HC) in the presence of such surfaces have been measured by using an assay performed with a thrombin-specific chromogenic substrate. A simple kinetic model of thrombin consumption is proposed. The relevant calculations, carried out with the help of a computer program, lead to determination of relative second order rate constants of thrombin adsorption and inhibitions by AT and HC in the presence of the polymers. In addition to thrombin adsorption, polystyrene surfaces bearing only sulphonate groups catalyse inhibition by AT, whereas polystyrene surfaces bearing either aspartate, glycinate or isophthalate sulphonamide groups catalyse both inhibitions by AT and HC.

Adsorption↗

Activation of the complement system by polysaccharidic surfaces bearing carboxymethyl, carboxymethylbenzylamide and carboxymethylbenzylamide sulphonate groups.

Substituted Sephadex derivatives bearing carboxymethyl (CM), CM-benzylamide (CMB), CM-propylamide (CMP) and CMB-sulphonate (CMBS) groups are used as models of polysaccharidic surfaces to measure the effects of substituting OH groups on the complement activating capacity (CAC) of the modified surfaces in normal human serum. CM substitution decreases and can suppress the CAC of Sephadex. Low CMB substitution also decreases the CAC, whereas high CMB or CMP substitutions increase it again after a minimum. In addition to C3 cleavage occurring at high substitution with CMB or CMP groups, the presence of CMB induces consumption of a protein, limiting CH50 measurements. The CAC variations could be due to rearrangements of the polymer surfaces at the aqueous interface with proteins. Highly substituted CMB-bearing surfaces could activate complement-like polystyrene surfaces. The presence of CMBS groups does not reduce the CAC of the surface. Such polymer surfaces, which are heparin-like concerning coagulation, are not heparin-like concerning complement inhibition.

Benzamides↗

Relationship between reduction of complement activation by polysaccharide surfaces bearing diethylaminoethyl groups and their degree of substitution.

The relationships between substitution of hydroxyl (OH) by diethylaminoethyl (DEAE) groups on cellulose membranes and the resulting reduction of complement activation are not clear. As a model, Sephadex has been randomly substituted with DEAE groups. Modification of 10% of the glucose units, i.e. about 3% of the groups, had no noticeable effect on the complement activating capacity of the polymer surface, whereas 20% substitution dramatically reduced it. This result could be explained in part by the fact that Sephadex-specific antibodies are not adsorbed by this modified surface. Thus, they cannot enhance complement activation as they do on Sephadex or cellulose. Comparison of our results with those published on Hemophan led us to the conclusion that a similar effect could occur. However, the degree of substitution of the membrane surface is probably greater than that of the membrane core due to the preparation process. Comparison with Sephadex substituted with other groups, or with other polymers bearing a variable density of OH groups, led us to the conclusion that, as hypothesized by Chenoweth (Artif Organs 1984; 8: 281-287), reduction of the availability of OH groups decreases complement activation, but the relationship is probably not linear. Moreover, replacement by other groups results in additional modulations due to (i) interactions between the groups and proteins responsible for formation or decay of the amplifying C3 convertase and/or (ii) decrease in recognition of the modified surface by antibodies which enhance complement activation on polysaccharides.

Adsorption↗

Regulation by sulphonate groups of complement activation induced by hydroxymethyl groups on polystyrene surfaces.

Reducing the complement-activating capacity of a polymer surface is important in improving its blood compatibility. Polystyrene surfaces bearing hydroxymethyl (CH2OH) groups activate the alternative pathway of complement. This activation depends strongly on the density of the groups. Polystyrene surfaces bearing sulphonate (SO3-) groups adsorb proteins, resulting in an apparent activation. Polystyrene surfaces bearing both types of groups in close proportions are not activators in human serum, due to the adsorption of a protein of the alternative pathway, which has a protecting effect, not found when a polymer surface bearing hydroxyl groups is mixed in serum with another polymer surface bearing SO3- groups. In the presence of purified proteins of alternative pathway, C3 convertase activity can be created on each of these surfaces by deposition of C3b, but their susceptibility to inactivation by regulatory proteins H and I depends on the types of chemical groups present on the surface and whether the surfaces were passivated or not before C3b deposition.

Adsorption↗

Specific interactions of polystyrene biomaterials with factor D of human complement.

The contact of blood with some biomaterials results in complement activation, primarily by the alternative pathway (AP). Insoluble polystyrene derivatives bearing isolated sulphonate groups (PSSO3) deplete complement, whereas identical surfaces substituted with both sulphonate and hydroxymethyl groups (PSCH2OH-SO3) are non-activators. Polystyrene sulphonate derivatives possess high adsorptive properties, particularly for serine proteases of the coagulation cascade. Thus, we studied the interactions between polystyrene derivatives and factor D, an enzyme essential for AP activation. C3 was activated when normal human serum (NHS) was incubated with PSSO3, whereas PSCH2OH-SO3 did not induce any specific C3 activation. Both polymers adsorbed factor D from serum, as shown by the loss of haemolytic factor D from NHS incubated with the polymers and by the specific adsorption of radiolabelled factor D. When bound to the polymers, factor D was not functional. The disappearance of factor D was in contradiction to the observed complement activation induced by PSSO3. When other AP components were studied, it was evident that PSSO3 adsorbed factor H even more rapidly and efficiently than factor D. Thus, the net effect was an immediate deregulation of the AP resulting in C3 activation, followed by inhibition of the AP when factor D was finally depleted. Pre-exposure of PSSO3 to NHS prevented any complement activation because the polymer was saturated with factor H, but still adsorbed factor D. Such properties could be beneficial during haemodialysis with membranes for uremic patients who have increased levels of factor D in their serum.

Biocompatible Materials↗

Complement activation and adsorption of protein fragments by functionalized polymer surfaces in human serum.

The interactions between blood and polymer surfaces used in extracorporeal circulations result in variable activations of the immune system of complement. Measuring concentrations of C3a or C5a in supernatant blood or serum after contact with the surface has been the most usual way of assessing this activation. Most polymer surfaces bearing various chemical groups were found to adsorb C3a and sometimes C5a. After taking into account adsorption, a good correlation was found between total C3a generated and CH50 units consumed by most of the polymer samples tested. Measuring only C3a remaining in the fluid phase should not be considered sufficient to conclude that a material surface is not an activator of complement.

Adsorption↗