PubMed Health⌕ Search

Biomedical subjects

D Lazaro

Publications and source records attributed to D Lazaro.

4 recordsLinked to original sources

Fully 3D Monte Carlo reconstruction in SPECT: a feasibility study.

In single photon emission computed tomography (SPECT) with parallel hole collimation, image reconstruction is usually performed as a set of bidimensional (2D) analytical or iterative reconstructions. This approach ignores the tridimensional (3D) nature of scatter and detector response function that affects the detected signal. To deal with the 3D nature of the image formation process, iterative reconstruction can be used by considering a 3D projector modelling the 3D spread of photons. In this paper, we investigate the value of using accurate Monte Carlo simulations to determine the 3D projector used in a fully 3D Monte Carlo (F3DMC) reconstruction approach. Given the 3D projector modelling all physical effects affecting the imaging process, the reconstruction problem is solved using the maximum likelihood expectation maximization (MLEM) algorithm. To validate the concept, three data sets were simulated and F3DMC was compared with two other 3D reconstruction strategies using analytical corrections for attenuation, scatter and camera point spread function. Results suggest that F3DMC improves spatial resolution, relative and absolute quantitation and signal-to-noise ratio. The practical feasibility of the approach on real data sets is discussed.

Algorithms↗

GATE: a simulation toolkit for PET and SPECT.

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http:/www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.

Computer Simulation↗

Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging.

Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(Tl) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated 99mTc point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 microns. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-182 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations.

Animals↗

[Postictal paralysis during video-EEG monitoring studies].

OBJECTIVE: To know the frequency of Todd s paralysis during the video EEG monitoring studies, to investigate in its pathophysiology, and to confirm its value to localise the epileptic focus. PATIENTS AND METHODS: We reviewed 114 monitoring studies, in 102 patients. RESULTS: Sixty patients had epileptic seizures. An obvious paresis was noted in four seizures of two patients (3 and 1, respectively). Both patients had frontal epilepsy. During the paralysis, in the first patient the EEG showed ictal discharges on the contralateral centrotemporal area. In the second patient, the EEG demonstrated slow waves in the contralateral frontal region. The ictal onset was contralateral to the paresis in all cases. No patient with pseudoseizures had paralysis. CONCLUSIONS: Postconvulsive paralysis are not frequent in video EEG monitoring studies. However, if present it points out to a contralateral seizure onset. In our series it happened in patients with frontal seizures. The EEG may help to clarify if it correspond to a true postictal phenomenon or to a ictal paralysis.

Adult↗