PubMed Health⌕ Search

Biomedical subjects

D Lee-Chahal

Publications and source records attributed to D Lee-Chahal.

2 recordsLinked to original sources

Quantitative contrast measurements in B-mode images comparison between experiment and theory.

Quantitative measurements of image contrast were carried out for B-mode images of anechoic spheres (cysts) embedded in a random scattering medium. Four transducer geometries were used: (a) f/5.7 spherical transducer in pulse echo mode, (b) f/2.4 spherical transducer in pulse echo mode, (c) f/2.4, 30 degrees cone (hybrid transducer), (d) f/5.7, 30 degrees cone (hybrid transducer). The image contrast was also calculated via two methods; (i) a three-dimensional computer simulation and (ii) a relatively simple numerical convolution which relates the image of a small point-like scatterer [point spread function (PSF)] to image contrast. Generally, good agreement was found between the experimental measurements and the values calculated via both theoretical methods. The results indicate that image contrast is not determined solely by the full width at half maximum (FWHM) of the PSF. In particular, the results demonstrate the importance of far off-axis contributions of the ultrasound beam to the significant degradation of contrast in images obtained with high resolution (low f-number) axicons.

Computers↗

Breast imaging with a conical transducer/annular array hybrid scanner.

A hybrid conical scanner consisting of a 37.5 degrees, 4 MHz conical receiver and a five element 5 cm dia. 4 MHz annular array transmitter has been developed for breast imaging. The ultrasound fields and imaging characteristics of three interesting geometries are compared. These are: (1) the annular array used in conventional pulse-echo mode, (2) the conical transducer used in combination with the full annular array and (3) the conical transducer used in combination with the center element of the annular array (simple conical scanner). Both conical systems provide extremely narrow (0.3 mm) beamwidths at -6dB but the cone/annular array combination has significantly improved sidelobe characteristics compared with the simple conical scanner. The combination of high resolution and reasonable sidelobe levels for the cone/annular array hybrid results in images with very fine speckle patterns and good definition of small structures. Breast images from young normal volunteers show that this approach has considerable potential for clinical application.

Adult↗