PubMed Health⌕ Search

Biomedical subjects

D Lyster

Publications and source records attributed to D Lyster.

7 recordsLinked to original sources

Biological evaluation of 2-fluoro-2-[123I]iodo-mannose (FIM): biological evaluation of FIM.

This paper describes the biodistribution of a radio-iodinated analog of fluorodeoxyglucose (FDG). 123I-2-fluoro-2-iodo-mannose (FIM) was investigated as a potential single photon emission tomography (SPECT) imaging agent. We also compare the results with the observed distribution of the classical PET agent 18F-FDG and newly developed 18F-difluorodeoxyglucose (DFDG). Following radioiodination, the final product was stable in-vitro for 24 hrs. Mice showed a rapid blood clearance and deiodination of the 123I-FIM reflected by high stomach and thyroid uptake. Comparison with 18F-FDG and 18F-DFDG revealed a large discrepancy between the 18F labeled sugars and the 123I-FIM biological distribution. The iodinated product was not found to be a metabolic marker for in-vivo studies.

Animals↗

Performance of the dynamic single photon emission computed tomography (dSPECT) method for decreasing or increasing activity changes.

Radionuclide imaging is now widely used whenever functional information is required. We present a new approach to dynamic SPECT imaging (dSPECT method) that uses a single slow rotation of a conventional camera and allows us to reconstruct a series of 3D images corresponding to the radiotracer distribution in the body at various times. Using simulations of various camera configurations and acquisition protocols, we have shown that this method is able to reconstruct washout half-lives with an accuracy greater than 90% when used with triple-head SPECT cameras. Accuracy decreases when using fewer camera heads, but dual-head geometries still give an accuracy greater than 80% for short and 90% for long half-lives and about 50-75% for single-head systems. Dynamic phantom experiments have yielded similar results. Presence of attenuation and background activity does not affect the accuracy of the dSPECT reconstructions. In all situations investigated satisfactory dynamic images were produced. A preliminary normal volunteer study measuring renal function was performed. The reconstructed dynamic images may be presented as a three-dimensional movie showing movement of the tracer through the kidneys and the measurement of the regional renal function can be performed. The time-activity curves determined from this dSPECT data are very similar to those obtained from dynamic planar scans.

Heart↗

Multiple line source array for SPECT transmission scans: simulation, phantom and patient studies.

UNLABELLED: Accurate attenuation and scatter corrections in quantitative SPECT studies require attenuation maps of the density distribution in the scanned object. These can be obtained from simultaneous emission/transmission scans. METHODS: A new method has been developed using a multiple line source array (MLA) for transmission scans, and its performance has been investigated using computer simulations and experimental data. The activity in the central lines of the MLA was higher than at the edges of the system, so that more transmission photons would be directed toward the thicker parts of the human body. A series of transmission-only and simultaneous emission/transmission studies were performed for different phantom configurations and human subjects. Attenuation maps were generated and used in reconstruction of attenuation-corrected emission images. RESULTS: The mu coefficients for attenuation maps obtained using the MLA system and simulated and experimental data display no artifacts and are qualitatively and quantitatively correct. For phantoms, the agreement between the measured and the true value of mu for water was found to be better than 4%. The attenuation-corrected emission images for the phantom studies demonstrate that the activity in the heart can be accurately reconstructed. A significant qualitative improvement was also obtained when the attenuation correction was used on patient data. CONCLUSION: Our results indicate that the MLA transmission source can be used in simultaneous transmission/emission imaging to generate accurate attenuation maps. These maps allow for performing an object-specific, attenuation correction of the emission images.

Computer Simulation↗

Kinetic studies of the mechanism of thrombocytopenia in patients with human immunodeficiency virus infection.

BACKGROUND: Isolated thrombocytopenia accompanied by increased amounts of platelet-associated antibody is a common manifestation of human immunodeficiency virus (HIV) infection, and the thrombocytopenia often improves with zidovudine. It is not clear whether the mechanism of HIV-related thrombocytopenia primarily involves autoimmune destruction of platelets or reduced platelet production by megakaryocytes. METHODS: We studied the survival of 111In-labeled autologous platelets and performed platelet imaging in 24 men with isolated HIV-related thrombocytopenia (16 who received no treatment and 8 who received zidovudine). We also studied 20 HIV-infected men with normal platelet counts (10 who received no treatment and 10 who received zidovudine) and studied 12 healthy seronegative men as controls. RESULTS: Mean (+/- SD) platelet survival was significantly decreased in both the untreated and the zidovudine-treated patients with HIV-related thrombocytopenia (to 92 +/- 33 and 129 +/- 44 hours, respectively; both P < 0.001), as compared with the normal controls (198 +/- 15 hours). Mean platelet survival was also significantly decreased in the HIV-infected patients with normal platelet counts (untreated, 162 +/- 23 hours, P < 0.01; zidovudine-treated, 166 +/- 35 hours, P < 0.05). Imaging studies, however, revealed no evidence of increased clearance of autologous platelets in the liver or spleen in any of these groups. Mean platelet production was significantly depressed in the untreated patients with thrombocytopenia (23,000 +/- 11,000 platelets per cubic millimeter per day, P < 0.001) as compared with the healthy controls (45,000 +/- 6,000 per cubic millimeter per day). Mean platelet production was significantly increased, however, in the men treated with zidovudine, both in those with thrombocytopenia (60,000 +/- 31,000 platelets per cubic millimeter per day, P < 0.01 vs. controls) and in those without thrombocytopenia (68,000 +/- 22,000 per cubic millimeter per day, P < 0.01). CONCLUSIONS: Although there was a moderate reduction in platelet survival in HIV-infected persons, these patients, regardless of platelet counts, also had decreased production of platelets, possibly due to viral infection of the megakaryocytes. Zidovudine appears to improve platelet production.

Blood Platelets↗