PubMed Health⌕ Search

Biomedical subjects

D M Bell

Publications and source records attributed to D M Bell.

At least 37 records · Page 2Linked to original sources

Effects of intermittent transdermal nitroglycerin on occurrence of ischemia after patch removal: results of the second transdermal intermittent dosing evaluation study (TIDES-II).

OBJECTIVES: We sought to evaluate the effects of intermittent transdermal nitroglycerin (TD-NTG) on the occurrence of ischemia during patch-off hours in patients with stable angina pectoris receiving a beta-adrenergic blocking agent or calcium antagonist, or both. BACKGROUND: The current recommendations for the use of intermittent TD-NTG may be associated with the occurrence of rebound ischemia. METHODS: This was a multicenter, randomized, double-blind, placebo-controlled, crossover trial with three study periods. Tolerability to TD-NTG was assessed in Period I. Seventy-two patients were assigned to receive either double-blind transdermal placebo or maximally tolerated TD-NTG for 2 weeks (Period II) and were then crossed over to the alternative treatment for another 2 weeks (Period III). The patients were instructed to apply medication daily at 8 AM, to remove it at 10 PM and to note symptoms and sublingual nitroglycerin (SL-NTG) use in a diary. The occurrence of ischemia was assessed from patient-perceived angina, symptom-limited exercise treadmill test (ETT) and 48-h ambulatory electrocardiographic (AECG) monitoring. RESULTS: Transdermal NTG (0.2 to 0.4 mg/h) significantly reduced the magnitude of ST segment depression at angina onset during ETT compared with placebo. Total angina frequency was not significantly different between TD-NTG (mean [+/-SD] 3.2 +/- 4.2) and placebo (3.3 +/- 5.2). During patch-off hours, angina frequency increased with TD-NTG (1.1 +/- 2.1) compared with placebo (0.7 +/- 1.6) (p = 0.03). Similar trends for an increase in ischemia after TD-NTG were also observed from AECG analyses. Specifically, ischemia frequency tended to be lower during patch-off hours for placebo than with TD-NTG (0.05 +/- 0.09 vs. 0.08 +/- 0.20 episodes/h, respectively, p = 0.08), even though frequency of ischemia tended to be higher during patch-on hours for placebo than with TD-NTG (0.12 +/- 0.19 vs. 0.07 +/- 0.15 episodes/h, respectively, p = 0.11). During placebo, ischemia frequency decreased 58% (patch-on to patch-off, p = 0.01) compared with a 14% increase with TD-NTG. These changes attenuate the usual circadian variation in ischemia. CONCLUSIONS: An increase in ischemia frequency during patch-off hours after use of intermittent TD-NTG was perceived by patients, and this subjective finding was supported by a corresponding trend for AECG ischemia to increase during these same hours.

Administration, Cutaneous↗

Bloodborne pathogen transmission in health care workers. Risks and prevention strategies.

Occupational transmission of hepatitis B virus (HBV), hepatitis C virus, and HIV has been documented. The risk for occupationally transmitted infection varies for these three viruses. Despite effective pre- and postexposure prophylaxis for HBV and recent recommendations for postexposure chemoprophylaxis after an HIV exposure, the best approach to prevent occupational bloodborne infection is the prevention of blood exposures. Epidemiologic data of percutaneous injuries and other blood contacts have provided the basis for prevention strategies. These strategies include the development of improved engineering controls, work practices, and personal protective equipment.

Blood-Borne Pathogens↗

SOX9 directly regulates the type-II collagen gene.

Mutations in human SOX9 are associated with campomelic dysplasia (CD), characterised by skeletal malformation and XY sex reversal. During chondrogenesis in the mouse, Sox9 is co-expressed with Col2a1, the gene encoding type-II collagen, the major cartilage matrix protein. Col2a1 is therefore a candidate regulatory target of SOX9. Regulatory sequences required for chondrocyte-specific expression of the type-II collagen gene have been localized to conserved sequences in the first intron in rats, mice and humans. We show here that SOX9 protein binds specifically to sequences in the first intron of human COL2A1. Mutation of these sequences abolishes SOX9 binding and chondrocyte-specific expression of a COL2A1-driven reporter gene (COL2A1-lacZ) in transgenic mice. Furthermore, ectopic expression of Sox9 trans-activates both a COL2A1-driven reporter gene and the endogenous Col2a1 gene in transgenic mice. These results demonstrate that COL2A1 expression is directly regulated by SOX9 protein in vivo and implicate abnormal regulation of COL2A1 during, chondrogenesis as a cause of the skeletal abnormalities associated with campomelic dysplasia.

Animals↗

Biomechanical properties of human tibias in long-term spinal cord injury.

Long-term spinal cord injury (SCI) profoundly alters skeletal structure and function. In this study, the biomechanical properties of tibias from persons with SCI and from individuals closely matched in age and size but without SCI were quantified at both the structural and material levels. Nondestructive torsion tests were performed to determine apparent shear moduli for the tibia. The cortical thicknesses and polar moment of inertia were determined numerically. Four-point bending tests were performed to determine flexural modulus of elasticity on cortical bone specimens of the tibia. The apparent shear moduli of the SCI tibias were found to be lower than the non-SCI tibias (p < 0.05). The cortical thicknesses of the SCI tibias were significantly thinner than the control tibias (p < 0.05), while the polar moment of inertia showed no significant differences between control and SCI tibial cross sections (p > 0.05). The flexural modulus of elasticity of the cortical bone specimens were lower in the SCI tibias than the controls (p < 0.05). These differences suggest that tibias may undergo micro-structural changes as well as structural adaptation following SCI, which alter their mechanical properties.

Aged↗

Architecture for a Federated Drug Reference in a managed care environment.

We describe a model of drug information query management that supports the integration of various types of pharmaceutical information and the delivery of that information through a common interface. Our prototype drug reference system makes use of the World Wide Web client/server architecture as a front-end to federate this data. Although originally intended as an electronic Hospital Formulary, the system has been redefined as a result of input from physicians to include formularies of multiple managed care plans. The underlying database is designed for integration with an electronic medical record as well as education and research resources for faculty and students in an academic medical center environment.

Computer Communication Networks↗

Investigations of patients of health care workers infected with HIV. The Centers for Disease Control and Prevention database.

OBJECTIVE: To assess the risk for transmission of the human immunodeficiency virus (HIV) from an infected health care worker to patients. DESIGN: Survey of investigators from health departments, hospitals, and other agencies who had elected to notify patients who had received care from health care workers infected with HIV. MEASUREMENTS: Information was collected about infected health care workers, their work practices, their patients' HIV test results, procedures that they did on those of their patients who were tested for HIV, and patient notification procedures. RESULTS: As of 1 January 1995, information about investigations of 64 health care workers infected with HIV was reported to the Centers for Disease Control and Prevention; HIV test results were available for approximately 22,171 patients of 51 of the 64 health care workers. For 37 of the 51 workers, no seropositive patients were reported among 13,063 patients tested for HIV. For the remaining 14 health care workers, 113 seropositive patients were reported among 9108 patients. Epidemiologic and laboratory follow-up did not show any health care worker to have been a source of HIV for any of the patients tested. CONCLUSION: Despite limitations, these data are consistent with previous assessments that state that the risk for transmission of HIV from a health care worker to a patient is very small. These data also support current recommendations that state that retrospective patient notification need not be done routinely.

Centers for Disease Control and Prevention, U.S.↗

Occupational risk of infection with human immunodeficiency virus.

The risk of HIV infection in surgical settings is a composite of overlapping risks related to the local prevalence of HIV, the route of exposure to HIV-infected blood, and the susceptibility of the worker. Studies continue to suggest that the risk of blood contact, including percutaneous injuries, remains appreciable. Prevention of such exposures in the operating and delivery room by adoption of safer instruments, work practices, and techniques and by the consistent use of appropriate personnel protective equipment must be viewed as a priority.

Acquired Immunodeficiency Syndrome↗

Preventing bloodborne pathogen transmission from health-care workers to patients. The CDC perspective.

The development of recommendations to manage the risk of bloodborne pathogen transmission from health-care workers to patients during invasive procedures has been difficult, primarily because of the limitations of available scientific data. Ultimately, both health-care workers and patients will be protected best by compliance with infection control precautions and by development of new instruments, protective equipment, and techniques that reduce the likelihood of intraoperative blood exposure without adversely affecting patient care.

Blood-Borne Pathogens↗

Occupational blood contact among prehospital providers.

STUDY OBJECTIVE: To assess the nature and frequency of blood contact (BC) among emergency medical service (EMS) workers. DESIGN: During an 8-month period, we interviewed EMS workers returning from emergency transport calls on a sample of shifts. We simultaneously conducted an HIV seroprevalence survey among EMS-transported patients at receiving hospitals served by these workers. SETTING: Three US cities with high AIDS incidence. PARTICIPANTS: EMS workers. RESULTS: During 165 shifts, 2,472 patients were attended. Sixty-two BCs (1 needlestick and 61 skin contacts) were reported. Individual EMS workers had a mean of 1.25 BCs, including .02 percutaneous exposures, per 100 patients attended. The estimated annual frequency of BC for an EMS worker at the study sites was 12.3, including .2 percutaneous exposures. For 93.5% of the BCs, the HIV serostatus of the source patients was unknown to the EMS worker. HIV seroprevalences among EMS-transported patients at the three receiving hospital emergency departments were 8.3, 7.7, and 4.1 per 100 patients; the highest rates were among male patients 15 to 44 years old who presented with pneumonia. CONCLUSION: EMS personnel regularly experience BCs, most of which are skin contacts. Because the HIV serostatus of the patient is usually unknown, EMS workers should practice universal precautions. Postexposure management should include a mechanism for voluntary HIV counseling and testing of the patient after transport and transmittal of the results to the EMS.

Adolescent↗

Skin and mucous membrane contacts with blood during surgical procedures: risk and prevention.

OBJECTIVE: To study the epidemiology and preventability of blood contact with skin and mucous membranes during surgical procedures. DESIGN: Observers present at 1,382 surgical procedures recorded information about the procedure, the personnel present, and the contacts that occurred. SETTING: Four US teaching hospitals during 1990. PARTICIPANTS: Operating room personnel in five surgical specialties. MAIN OUTCOME MEASURES: Numbers and circumstances of contact between the patient's blood (or other infective fluids) and surgical personnel's mucous membranes (mucous membrane contacts) or skin (skin contacts, excluding percutaneous injuries). RESULTS: A total of 1,069 skin (including 620 hand, 258 body, and 172 face) and 32 mucous membrane (all affecting eyes) contacts were observed. Surgeons sustained most contacts (19% had > or = 1 skin contact and 0.5% had > or = 1 mucous membrane-eye contact). Hand contacts were 72% lower among surgeons who double gloved, and face contacts were prevented reliably by face shields. Mucous membrane-eye contacts were significantly less frequent in surgeons wearing eyeglasses and were absent in surgeons wearing goggles or face shields. Among surgeons, risk factors for skin contact depended on the area of contact: hand contacts were associated most closely with procedure duration (adjusted odds ratio [OR], 9.4; > or = 4 versus < 1 hour); body contacts (arms, legs, and torso) with estimated blood losses (adjusted OR, 8.4; > or = 1,000 versus < 100 mL); and face contacts, with orthopedic service (adjusted OR, 7.5 compared with general surgery). CONCLUSION: Skin and mucous membrane contacts are preventable by appropriate barrier precautions, yet occur commonly during surgery. Surgeons who perform procedures similar to those included in this study should strongly consider double gloving, changing gloves routinely during surgery, or both.

Adult↗

Percutaneous exposures to HIV-infected blood. Among dental workers enrolled in the CDC Needlestick Study.

The authors found that 19 percutaneous exposures among dental workers occurred both during and after use of instruments such as syringe needles and scalers. Specific information about the device and action associated with an exposure is important for prevention efforts, including safer instruments and work practices. Most of these exposures probably involved smaller, rather than larger, amounts of blood infected with the human immunodeficiency virus. To our knowledge, none of the exposures resulted in HIV transmission to an enrolled dental worker.

Accidents, Occupational↗

HIV transmission in the health-care setting. Risks to health-care workers and patients.

Transmission of HIV from patients to health care workers (HCWs) has been documented. Data from surveillance projects and epidemiologic studies provide the basis for evaluation of the risk of HIV transmission in health care settings. Strategies to further reduce this risk should focus on prevention of blood contacts between HCWs and patients through the use of universal precautions and implementation of new or modified medical devices, techniques, and personal protective equipment.

HIV Infections↗

Surveillance of HIV infection and zidovudine use among health care workers after occupational exposure to HIV-infected blood. The CDC Cooperative Needlestick Surveillance Group.

OBJECTIVE: To study the risk for human immunodeficiency virus (HIV) infection and the patterns of use and associated toxicity of zidovudine among health care workers after an occupational exposure to HIV. DESIGN: An ongoing, prospective surveillance project conducted by the Centers for Disease Control and Prevention. PARTICIPANTS: Exposed workers voluntarily reported by 312 U.S. health care facilities from August 1983 to June 1992. RESULTS: Four of 1103 enrolled workers with percutaneous exposure to HIV-infected blood seroconverted (HIV seroconversion rate, 0.36%; upper limit of the 95% Cl, 0.83%); no enrolled workers with mucous membrane (n = 75) or skin (n = 67) contact seroconverted. During October 1988 to June 1992, 31% of 848 enrolled workers used zidovudine after exposure; this proportion increased from 5% during October through December 1988 to 43% during January through June 1992. Despite using zidovudine after exposure, one worker became infected with a strain of HIV that was apparently sensitive to zidovudine. Adverse symptoms, most commonly nausea, malaise or fatigue, and headache, were reported by 75% of workers using zidovudine; 31% of workers did not complete planned courses of zidovudine because of adverse events. CONCLUSIONS: The risk for HIV seroconversion after percutaneous exposure to HIV-infected blood is 0.36%, which is similar to previous estimates. Zidovudine is used after exposure by a sizable proportion of health care workers enrolled in the project despite frequent, minor, associated symptoms. Documented failures of postexposure zidovudine prophylaxis, including in one worker enrolled in this study, indicate that if zidovudine is protective, any protection afforded is not absolute. Postexposure zidovudine, if used, requires careful consideration of possible risks and benefits.

Centers for Disease Control and Prevention, U.S.↗

Risk of human immunodeficiency virus infection among emergency department workers.

PURPOSE: To estimate (1) the prevalence of human immunodeficiency virus (HIV) infection in emergency department (ED) patients, (2) the frequency of blood contact (BC) in ED workers (EDWs), (3) the efficacy of gloves in preventing BC, and (4) the risk of HIV infection in EDWs due to BC. PATIENTS AND METHODS: We conducted an 8-month study in three pairs of inner-city and suburban hospital EDs in high AIDS incidence areas in the United States. At each hospital, blood specimens from approximately 3,400 ED patients were tested for HIV antibody. Observers monitored BC and glove use by EDWs. RESULTS: HIV seroprevalence was 4.1 to 8.9 per 100 patient visits in the 3 inner-city EDs, 6.1 in 1 suburban ED, and 0.2 and 0.7 in the other 2 suburban EDs. The HIV infection status of 69% of the infected patients was unknown to ED staff. Seroprevalence rates were highest among patients aged 15 to 44 years, males, blacks and Hispanics, and patients with pneumonia. BC was observed in 379 (3.9%) of 9,793 procedures; 362 (95%) of the BCs were on skin, 11 (3%) were on mucous membranes, and 6 (2%) were percutaneous. Overall procedure-adjusted skin BC rates were 11.2 BCs per 100 procedures for ungloved workers and 1.3 for gloved EDWs (relative risk = 8.8; 95% confidence interval = 7.3 to 10.3). In the high HIV seroprevalence EDs studied, 1 in every 40 full-time ED physicians or nurses can expect an HIV-positive percutaneous BC annually; in the low HIV seroprevalence EDs studied, 1 in every 575. The annual occupational risk of HIV infection for an individual ED physician or nurse from performing procedures observed in this study is estimated as 0.008% to 0.026% (1 in 13,100 to 1 in 3,800) in a high HIV seroprevalence area and 0.0005% to 0.002% (1 in 187,000 to 1 in 55,000) in a low HIV seroprevalence area. CONCLUSIONS: In both inner-city and suburban EDs, patient HIV seroprevalence varies with patient demographics and clinical presentation; the infection status of most HIV-positive patients is unknown to ED staff. The risk to an EDW of occupationally acquiring HIV infection varies by ED location and the nature and frequency of BC; this risk can be reduced by adherence to universal precautions.

Adolescent↗

Risk of occupational infection with blood-borne pathogens in operating and delivery room settings.

Surveillance data and case reports substantiate that health care workers are at risk for occupationally acquired infection with blood-borne pathogens. The risk of transmission of blood-borne pathogens to a health care worker depends on the prevalence of blood-borne pathogen infection among patients, the likelihood of transmission of infection per blood contact, and the nature and frequency of occupational blood contacts. In surgical and obstetrical settings, blood contact varies with occupation, specialty, procedures performed, and precautions used. Many contacts appear to be preventable by changes in technique or instrument design and by use of protective barriers. Studies are needed to assess the impact of such interventions.

Blood-Borne Pathogens↗