Classification of sleep-disordered breathing.

Increasing recognition of sleep-disordered breathing (SDB) and its morbidity have prompted reevaluation of techniques to identify respiratory events during sleep. The present study was designed to evaluate the utility of various metrics of SDB and to identify the optimal respiratory metric that objectively correlates to symptoms of excessive daytime somnolence (EDS). Metrics were derived from combinations of conventional apnea/hypopnea, flow limitation events (transient elevated upper airway resistance identified by characteristic flattening on the flow/time tracing, using a noninvasive nasal cannula technique), desaturation, and arousal. A total of 137 subjects underwent clinical evaluation and nocturnal polysomnogram. In 34 randomly selected subjects, the best metrics for discriminating between 13 subjects with no EDS/snoring and 21 patients with EDS and snoring were identified by receiver operator curve analysis. Of the metrics and cut points tested, a total respiratory disturbance index (RDI(Total), sum of apneas, hypopnea, and flow limitation events) of 18 events/h was found to have the best discriminant ability (100% sensitivity and 96% specificity). Prospective testing of this metric was then performed with the remaining 103 subjects (14 nonsnoring non-EDS, 21 snoring non-EDS, 68 snoring with EDS). Using this cutoff of 18 events/h, we obtained 71% sensitivity and 60% specificity for identifying subjects with EDS. We conclude that, in subjects with upper airway dysfunction, an index that incorporates all respiratory events provides the best quantitative physiological correlate to EDS.

Adult↗

Obesity hypoventilation syndrome as a spectrum of respiratory disturbances during sleep.

OBJECTIVE: To identify the spectrum of respiratory disturbances during sleep in patients with obesity hypoventilation syndrome (OHS) and to examine the response of hypercapnia to treatment of the specific ventilatory sleep disturbances. DESIGNS AND METHODS: Twenty-three patients with chronic awake hypercapnia (mean [+/- SD] PaCO(2), 55 +/- 6 mm Hg) and a respiratory sleep disorder were retrospectively identified. Nocturnal polysomnography testing was performed, and flow limitation (FL) was identified from the inspiratory flow-time contour. Obstructive hypoventilation was inferred from sustained FL coupled with O(2) desaturation that was corrected with treatment of the upper airway obstruction. Central hypoventilation was inferred from sustained O(2) desaturation that persisted after the correction of the upper airway obstruction. Treatment was initiated, and follow-up awake PaCO(2) measurements were obtained (follow-up range, 4 days to 7 years). RESULTS: A variable number of obstructive sleep apneas/hypopneas (ie, obstructive sleep apnea-hypopnea syndrome [OSAHS]) were noted (range, 9 to 167 events per hour of sleep). Of 23 patients, 11 demonstrated upper airway obstruction alone (apnea-hypopnea/FL) and 12 demonstrated central sleep hypoventilation syndrome (SHVS) in addition to a variable number of OSAHS. Treatment aimed at correcting the specific ventilatory abnormalities resulted in correction of the chronic hypercapnia in all compliant patients (compliant patients: pretreatment, 57 +/- 6 mm Hg vs post-treatment, 41 +/- 4 mm Hg [p < 0.001]; noncompliant patients: pretreatment, 52 +/- 6 mm Hg vs post-treatment, 51 +/- 3 mm Hg; [difference not significant]). CONCLUSIONS: This study demonstrates that OHS encompasses a variety of distinct pathophysiologic disturbances that cannot be distinguished clinically at presentation. Sustained obstructive hypoventilation due to partial upper airway obstruction was demonstrated as an additional mechanism for OHS that is not easily classified as SHVS or OSAHS.

Adult↗

Interobserver agreement among sleep scorers from different centers in a large dataset.

STUDY OBJECTIVES: To evaluate epoch by epoch agreement in sleep stage assignment between scorers from different laboratories. DESIGN: N/A. METHODS: 62 NPSGs were selected for analysis from 3 sleep centers (38 diagnostic studies for sleep disordered breathing [SDB], 10 studies during CPAP titration, and 14 studies in subjects with no sleep related complaints or sleep pathology). The sleep recording montage consisted of at least 2 EEG leads, left and right EOG and a submental EMG. Scoring was performed manually by 5 experienced sleep technologists. No scorer had knowledge of any other scorers' results. Agreement was tabulated both for sleep stage distribution and on an epoch by epoch basis for the entire data set and the normal and SDB subsets. MEASUREMENTS AND RESULTS: The mean epoch by epoch agreement between scorers for all records was 73% (range 67-82%). Agreements were higher in the normal subset (mean 76%, range 65-85%) than in the SDB subset (mean 71%, range 65-78%). There was significant variability in agreement between records and between pairs of scorers. Overall, 75% of epochs had at least 4 of the 5 scorers in agreement on the sleep stage and 96% of epochs had agreement of at least 3 of the 5 scorers. CONCLUSIONS: The level of agreement in sleep stage assignment varies between scorers, by diagnosis, and by record. The level of agreement between laboratories is lower than what can be maintained between scorers within the same laboratory. This warrants caution when comparing data scored in separate laboratories. The lower agreement in SDB patients supports the generally held view that sleep fragmentation makes application of the R&K rules less reliable.

Adolescent↗

Non-Invasive detection of respiratory effort-related arousals (REras) by a nasal cannula/pressure transducer system.

STUDY OBJECTIVES: The published AASM guidelines approve use of a nasal cannula/pressure transducer to detect apneas/hypopneas, but require esophageal manometry for Respiratory Effort-Related Arousals (RERAs). However, esophageal manometry may be poorly tolerated by many subjects. We have shown that the shape of the inspiratory flow signal from a nasal cannula identifies flow limitation and elevated upper-airway resistance. This study tests the hypothesis that detection of flow limitation events using the nasal cannula provides a non-invasive means to identify RERAs. DESIGN: N/A. SETTING: N/A. PATIENTS: 10 UARS/OSAS and 5 normal subjects INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: All subjects underwent full NPSG. Two scorers identified events from the nasal cannula signal as apneas, hypopneas, and flow limitation events. Two additional scorers identified events from esophageal manometry. Arousals were scored in a separate pass. Interscorer reliability and intersignal agreement were assessed both without and with regard to arousal. The total number of respiratory events identified by the two scorers of the nasal cannula was similar with an Intraclass Correlation (ICC) =0.96, and was essentially identical to the agreement for the two scorers of esophageal manometry (ICC=0.96). There was good agreement between the number of events detected by the two techniques with a slight bias towards the nasal cannula (4.5 events/hr). There was no statistically significant difference (bias 0.9/hr, 95%CI -0.3-2.0) between the number of nasal cannula flow limitation events terminated by arousal and manometry events terminated by arousal (RERAs). CONCLUSION: The nasal cannula/pressure transducer provides a non-invasive reproducible detector of all events in sleep disordered breathing; in particular, it detects the same events as esophageal manometry (RERAs).

Adult↗

Rates of sensor loss in unattended home polysomnography: the influence of age, gender, obesity, and sleep-disordered breathing.

OBJECTIVES: To evaluate study failure and sensor loss in unattended home polysomnography and their relationship to age, gender, obesity, and severity of sleep-disordered breathing (SDB). DESIGN: A cross-sectional analysis of data gathered prospectively for the Sleep Heart Health Study (SHHS). SETTING: Unattended polysomnography was performed in participants' homes by the staff of the sites that are involved in SHHS. PARTICIPANTS: 6,802 individuals who met the inclusion criteria (age >40 years, no history of treatment of sleep apnea, no tracheostomy, no current home oxygen therapy) for SHHS. RESULTS: A total of 6802 participants had 7151 studies performed. 6161 of 6802 initial studies (90.6%) were acceptable. Obesity was associated with a decreased likelihood of a successful initial study. After one or more attempts, 6440 participants (94.7%) had studies that were judged as acceptable. The mean duration of scorable signals for specific channels ranged from 5.7 to 6.8 hours. The magnitudes of the effects of age, gender, BMI, and RDI on specific signal durations were not clinically significant. CONCLUSION: Unattended home PSG as performed for SHHS was usually successful. Participant characteristics had very weak associations with duration of scorable signal. This study suggests that unattended home PSG, when performed with proper protocols and quality controls, has reasonable success rates and signal quality for the evaluation of SDB in clinical and research settings.

Age Factors↗

CO(2) homeostasis during periodic breathing in obstructive sleep apnea.

The contribution of apnea to chronic hypercapnia in obstructive sleep apnea (OSA) has not been clarified. Using a model (D. M. Rapoport, R. G. Norman, and R. M. Goldring. J. Appl. Physiol. 75: 2302-2309, 1993), we previously illustrated failure of CO(2) homeostasis during periodic breathing resulting from temporal dissociation between ventilation and perfusion ("temporal V/Q mismatch"). This study measures acute kinetics of CO(2) during periodic breathing and addresses interapnea ventilatory compensation for maintenance of CO(2) homeostasis in 11 patients with OSA during daytime sleep (37-171 min). Ventilation and expiratory CO(2) and O(2) fractions were measured on a breath-by-breath basis by means of a tight-fitting full facemask. Calculations included CO(2) excretion, metabolic CO(2) production, and CO(2) balance (metabolic CO(2) production - exhaled CO(2)). CO(2) balance was tabulated for each apnea/hypopnea event-interevent cycle and as a cumulative value during sleep. Cumulative CO(2) balance varied (-3,570 to +1,388 ml). Positive cumulative CO(2) balance occurred in the absence of overall hypoventilation during sleep. For each cycle, positive CO(2) balance occurred despite increased interevent ventilation to rates as high as 45 l/min. This failure of CO(2) homeostasis was dependent on the event-to-interevent duration ratio. The results demonstrate that 1) periodic breathing provides a mechanism for acute hypercapnia in OSA, 2) acute hypercapnia during periodic breathing may occur without a decrease in average minute ventilation, supporting the presence of temporal V/Q mismatch, as predicted from our model, and 3) compensation for CO(2) accumulation during apnea/hypopnea may be limited by the duration of the interevent interval. The relationship of this acute hypercapnia to sustained chronic hypercapnia in OSA remains to be further explored.

Adult↗

Effects of varying approaches for identifying respiratory disturbances on sleep apnea assessment.

Varying approaches to measuring the respiratory disturbance index (RDI) may lead to discrepant estimates of the severity of sleep-disordered breathing (SDB). In this study, we assessed the impact of varying the use of corroborative data (presence and degree of desaturation and/or arousal) to identify hypopneas and apneas. The relationships among 10 RDIs defined by various definitions of apneas and hypopneas were assessed in 5,046 participants in the Sleep Heart Health Study (SHHS) who underwent overnight unattended 12-channel polysomnography (PSG). The magnitude of the median RDI varied 10-fold (i.e., 29.3 when the RDI was based on events identified on the basis of flow or volume amplitude criteria alone to 2.0 for an RDI that required an associated 5% desaturation with events). The correlation between RDIs based on different definitions ranged from 0.99 to 0.68. The highest correlations were among RDIs that required apneas and hypopneas to be associated with some level of desaturation. Lower correlations were observed between RDIs that required desaturation as compared with RDIs defined on the basis of amplitude criteria alone or associated arousal. These data suggest that different approaches for measuring the RDI may contribute to substantial variability in identification and classification of the disorder.

Adult↗

Sleep habits of Long Island Rail Road commuters.

STUDY OBJECTIVES: We addressed the issue of how commuting affects sleep habits, and its association with general health and potential sleep disorders in individuals on a large, U.S. commuter rail system. DESIGN: Postage-paid mail back questionnaires were distributed to commuters over 6 consecutive weekdays. The questionnaire incorporated previously validated questions regarding sleep habits. SETTING: Questionnaires were dispensed at 15 different rail stations. PARTICIPANTS: 21,000 commuters accepted the questionnaire. MEASUREMENTS AND RESULTS: Data was analyzed by total group and length of commute. A total of 4715 (22%) questionnaires were returned. Over 50% of the sample reported difficulty with sleep and wakefulness while only 3% sought professional help. Sleep apnea was suspected in 4.2% of male and 1% of female respondents and was associated with increased reports of excessive daytime sleepiness, and history of hypertension, diabetes and obesity. Total nocturnal sleep time was significantly less in those subjects with long commutes. Seventy percent of respondents reported napping during the commute. Length of commute was associated with hypertension. CONCLUSION: Commuting long distances negatively impacts one's ability to capture adequate sleep. Data suggests that there may be significant numbers of respondents with unrecognized sleep disorders which further impact on general health.

Adult↗

Cardiogenic oscillations on the airflow signal during continuous positive airway pressure as a marker of central apnea.

UNLABELLED: Therapeutic decisions in patients with sleep apnea (eg, adjustment of continuous positive airway pressure [CPAP]) depend on differentiating central from obstructive apnea. Obstructive apnea is defined by cessation of airflow in the presence of continued respiratory effort, which is conventionally inferred from chest wall movement or intrathoracic pressure swings. Cardiogenic oscillations in the airflow have been observed during some central apneas, but there is controversy over whether they correlate with airway patency. The present study investigates whether these oscillations are markers of the absence of respiratory effort (central apnea) without regard to airway patency. METHODS: We examined 648 apneas in 52 patients undergoing nocturnal polysomnograms and CPAP titrations. Airflow was measured using the output of the CPAP generator, and apneas were identified from reduction of airflow to < 10% for > 10 s. We used only the presence or complete absence of thoracoabdominal motion to classify apneas: obstructive apnea when motion was present (297 apneas); and central apnea if motion was totally absent (351 apneas). Central apneas most often occurred at sleep onset or followed arousal with a big breath. Using only the flow signal, all apneas were examined for the presence of cardiogenic oscillation by an observer blinded to other signals and apnea types. RESULTS: No obstructive apnea showed definite cardiogenic oscillations. In four cases, there was a suggestion of oscillation that was not regular enough to be called cardiac. Sixty percent of central apneas showed clear, regular oscillations at cardiac frequency. Cardiogenic oscillations also were seen intermittently during quiet exhalation in apnea-free periods. CONCLUSION: The presence of cardiogenic oscillations on the CPAP flow signal is a specific indicator of central apnea and may have a role in self-titrating CPAP algorithms. We speculate that transmission of these cardiac-induced oscillations may relate to the relaxation of thoracic muscles during central apnea and is impeded by high muscle tone during obstructive apnea.

Electrocardiography↗

Methods for obtaining and analyzing unattended polysomnography data for a multicenter study. Sleep Heart Health Research Group.

This paper reviews the data collection, processing, and analysis approaches developed to obtain comprehensive unattended polysomnographic data for the Sleep Heart Health Study, a multicenter study of the cardiovascular consequences of sleep-disordered breathing. Protocols were developed and implemented to standardize in-home data collection procedures and to perform centralized sleep scoring. Of 7027 studies performed on 6697 participants, 5534 studies were determined to be technically acceptable (failure rate 5.3%). Quality grades varied over time, reflecting the influences of variable technician experience, and equipment aging and modifications. Eighty-seven percent of studies were judged to be of "good" quality or better, and 75% were judged to be of sufficient quality to provide reliable sleep staging and arousal data. Poor submental EMG (electromyogram) accounted for the largest proportion of poor signal grades (9% of studies had <2 hours artifact free EMG signal). These data suggest that with rigorous training and clear protocols for data collection and processing, good-quality multichannel polysomnography data can be obtained for a majority of unattended studies performed in a research setting. Data most susceptible to poor signal quality are sleep staging and arousal data that require clear EEG (electroencephalograph) and EMG signals.

Electroencephalography↗

Detection of flow limitation with a nasal cannula/pressure transducer system.

We previously showed that upper airway resistance can be inferred from the inspiratory flow contour during continuous positive airway pressure (CPAP) titration in obstructive sleep apnea syndrome (OSAS). The present study examines whether similar information can be obtained from inspiratory flow measured by a nasal cannula/pressure transducer. Ten symptomatic patients (snoring, upper airway resistance syndrome [UARS], or OSAS) and four asymptomatic subjects underwent nocturnal polysomnography (NPSG) with monitoring of flow (nasal cannula) and respiratory driving pressure (esophageal or supraglottic catheter). For each breath the inspiratory flow signal was classified as normal, flattened, or intermediate by custom software. "Resistance" was calculated from peak inspiratory flow and pressure, and normalized to the resistance during quiet wakefulness. Resistance in all stages of sleep was increased for breaths with flattened (387 +/- 188%) or intermediate (292 +/- 163%) flow contour. In combination with apnea-hypopnea index (AHI), identification of "respiratory events," consisting of consecutive breaths with a flattened contour, allowed differentiation of symptomatic from asymptomatic subjects. Our data show that development of a plateau on the inspiratory flow signal from a nasal cannula identifies increased upper airway resistance and the presence of flow limitation. In patients with symptoms of excessive daytime somnolence and low AHI this may help diagnose the UARS and separate it from nonrespiratory causes of sleep fragmentation.

Adult↗

Relative occurrence of flow limitation and snoring during continuous positive airway pressure titration.

OBJECTIVES: To examine the relative temporal appearance of flow limitation and snoring during continuous positive airway pressure (CPAP) titration, compare their sensitivity as indicators of airway obstruction, and assess their relative utility as feedback variables for automatic titration of CPAP. DESIGN: Retrospective review of data. SETTING: University teaching hospital. PATIENTS: Fifty-three patients diagnosed as having obstructive sleep apnea or upper airway resistance syndrome undergoing CPAP titration. MEASUREMENTS AND RESULTS: We used a prototype automatic CPAP device that adjusts pressure in response to apnea, snoring, and/or flow limitation. The present study takes advantage of the frequent automatic decreases in pressure from a therapeutic level, as well as any technician-initiated decreases in pressure. We tabulated, for each pressure decrease of >0.4 cm H2O, the occurrences of snoring alone, flow limitation alone, or simultaneous appearance of both. Of 2,177 automatic pressure decreases, 64% resulted in flow limitation alone, 8% in snoring alone, and 22% in the simultaneous occurrence of both. Overall, 86% of decreases resulted in flow limitation alone or were simultaneous with snoring, whereas 30% of decreases resulted in snoring alone or were simultaneous with flow limitation. In 10 of 35 patients, snoring alone occurred in > 10% of the pressure decreases. In all but 5 of 133 manual pressure decreases, flow limitation developed at or above the pressure at which snoring developed. CONCLUSIONS: While detection of snoring occasionally provided additional information, overall flow limitation was the earliest indicator of obstruction during decreases in CPAP.

Adolescent↗

An international study on sleep disorders in the general population: methodological aspects of the use of the Sleep-EVAL system.

The comparability among epidemiological surveys of sleep disorders has been encumbered because of the array of methodologies used from study to study. The present international initiative addresses this limitation. Many such studies using the exact same methodology are being completed in six European countries (France, the United Kingdom, Germany, Italy, Portugal, and Spain), two Canadian cities (metropolitan areas of Montreal and Toronto), New York State, and the city of San Francisco. These surveys have been undertaken with the aim of documenting the prevalence of sleep disorders in the general population according to criteria of the Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-IV) and the International Classification of Sleep Disorders (ICSD-90). Data are gathered over the telephone by lay interviewers using the Sleep-EVAL expert system. This paper describes the methodology involved in the realization of these studies. Sample design and selection procedures are discussed.

Adolescent↗

The Sleep Heart Health Study: design, rationale, and methods.

The Sleep Heart Health Study (SHHS) is a prospective cohort study designed to investigate obstructive sleep apnea (OSA) and other sleep-disordered breathing (SDB) as risk factors for the development of cardiovascular disease. The study is designed to enroll 6,600 adult participants aged 40 years and older who will undergo a home polysomnogram to assess the presence of OSA and other SDB. Participants in SHHS have been recruited from cohort studies in progress. Therefore, SHHS adds the assessment of OSA to the protocols of these studies and will use already collected data on the principal risk factors for cardiovascular disease as well as follow-up and outcome information pertaining to cardiovascular disease. Parent cohort studies and recruitment targets for these cohorts are the following: Atherosclerosis Risk in Communities Study (1,750 participants), Cardiovascular Health Study (1,350 participants), Framingham Heart Study (1,000 participants), Strong Heart Study (600 participants), New York Hypertension Cohorts (1,000 participants), and Tucson Epidemiologic Study of Airways Obstructive Diseases and the Health and Environment Study (900 participants). As part of the parent study follow-up procedures, participants will be surveyed at periodic intervals for the incidence and recurrence of cardiovascular disease events. The study provides sufficient statistical power for assessing OSA and other SDB as risk factors for major cardiovascular events, including myocardial infarction and stroke.

Adult↗

Detection of respiratory events during NPSG: nasal cannula/pressure sensor versus thermistor.

Recording of respiratory airflow is an integral part of polysomnography (NPSG). It is conventionally monitored with a thermistor that measures temperature as a surrogate of flow. The subjectivity of interpreting hypopnea from this signal has prompted us to measure nasal airflow directly with a simple pneumotachograph consisting of a standard nasal cannula connected to a 2-cm H2O pressure transducer. We manually analyzed respiratory events using simultaneous thermistor and nasal cannula in 11 patients with obstructive sleep apnea syndrome (OSAS) and 9 with upper airway resistance syndrome (UARS). Definite events were scored separately for each signal when amplitude was <50% for >10 seconds. Events were also scored on the nasal cannula signal when the flattened shape of the signal suggested flow limitation, and these were tabulated separately. Definite events in one signal were tabulated by whether the other signal showed a definite event or not. In addition, nasal cannula events were compared to a more liberal thermistor criterion (any change in the signal for > or = 2 breaths). Visually, events were more easily recognized on the nasal cannula signal than on the thermistor signal. In OSAS, 1,873 definite thermistor events were detected. Of these, 99.1% were detected by nasal cannula, and 0.9% were missed. Of 3,541 definite nasal cannula events, 51.9% were detected by definite thermistor criteria; 75.0% were detected by liberal thermistor criteria; 25.0% were missed. In UARS, 123 definite thermistor events were detected. Of these, 89.4% were detected by nasal cannula and 10.6% were missed. Nine hundred and three nasal cannula events were detected. However, only 17.2% of these were detected by definite thermistor criteria; 38.6% were detected by liberal thermistor criteria; 61.4% were completely undetected by thermistor. When events identified on the nasal cannula by flow limitation alone were excluded, the thermistor detected 30.1% of events by definite criteria and 78.6% by liberal criteria, still leaving 21.4% completely undetected by the thermistor. We conclude that the nasal cannula reliably detects respiratory events seen by thermistor. Additional events (including some characterized only by flow limitation) that help define the UARS, were recognized by nasal cannula but often completely missed by thermistor. We propose that respiratory monitoring during NPSG with nasal cannula significantly improves event detection and classification over that with thermistor.

Catheterization↗

Methods to stabilize the upper airway using positive pressure.

Nasal CPAP has become the treatment of choice for obstructive sleep apnea because of its predictable physiologic effect over the full spectrum of disease. The physiology of the upper airway during sleep mimics the behavior of a collapsible tube; CPAP prevents the negative intraluminal pressure thought to cause apnea, hypopnia and increases in airway resistance. Titration of CPAP for optimal therapy is not well standardized. However, treatment algorithms should aim to eliminate apneas, hypopneas, snoring, significant O2 desaturations, and EEG arousals. Flow limitation (recognized from the shape of the flow tracing) may also need to be eliminated. Once prescribed, CPAP is effective but compliance with therapy is not uniform or optimal. Attention to details of comfort and various enhancements to CPAP may improve results but need to be validated. Automatically adjusting CPAP may provide a new therapeutic option, but again needs to be carefully evaluated to define improvements possible in ease of titration, effectiveness, and ultimate compliance.

Airway Obstruction↗

Mechanism of relief of tachypnea during pressure support ventilation.

Pressure support ventilation (PSV) provides a range of ventilatory support from partial respiratory muscle unloading, where inspiratory work is shared between the patient and the mechanical ventilator, to total respiratory muscle unloading, where inspiratory work is performed solely by the ventilator. This study is designed to determine if minimizing work fully accounts for relief of tachypnea during PSV. We examined respiratory parameters over a range of PSV that includes the crossover from partial to total respiratory muscle unloading. Eight studies were obtained on seven intubated patients in respiratory failure. Ventilation, occlusion pressure (P0.1), and patient inspiratory work (WOBinsp) were measured while PSV was varied. In all patients, WOBinsp decreased as PSV increased. The level of PSV where WOBinsp was minimized was identified; this marked the crossover from partial to total respiratory muscle unloading. Frequency decreased with increasing PSV but remained elevated (range, 22 to 38 breaths/min) at the crossover. Frequency was normalized only at PSV levels 131 to 193% of the levels of pressure at the crossover. Tidal volume (VT) changed little during partial support and averaged 5.9 mL/kg at the crossover. VT increased only on PSV providing total unloading. Six of seven patients exhibited increasing static compliance with increasing VT suggesting alveolar recruitment. P0.1 tracked WOBinsp over the entire range of PSV (r = 0.95, p < 0.001). The normalization of frequency observed above the crossover coincided with increasing VT rather than decreasing work. These observations suggest that reflexes resulting from increased VT and/or alveolar recruitment may have contributed to the normalization of frequency.

Adult↗

Flow limitation as a noninvasive assessment of residual upper-airway resistance during continuous positive airway pressure therapy of obstructive sleep apnea.

Many patients with obstructive sleep apnea syndrome (OSAS), despite therapy with nasal continuous positive airway pressure (CPAP), have persisting daytime somnolence that may be due to a persistently elevated upper-airway resistance associated with electroencephalographic (EEG) arousals. We tested the hypothesis that elevated upper-airway resistance can be inferred from the contour of the inspiratory flow tracing obtained from a conventional CPAP circuit. This may provide a noninvasive method for determining optimal CPAP. Data were collected during a CPAP titration of an upper-airway model and in eight patients with OSAS. Estimated inspiratory resistance was calculated from esophageal pressure, CPAP mask pressure, and inspiratory flow. At high CPAP, resistance was low and inspiratory flow contour was found to be rounded. At low CPAP, resistance was high and flow contour developed a plateau suggesting flow limitation. We also noted that the CPAP pressure at which high resistance developed, and at which flow limitation appeared, showed hysteresis. We conclude that when respiration is stable, the contour of inspiratory flow tracing from a CPAP system can be used to infer the presence of elevated upper-airway resistance and flow limitation. Optimizing flow contour may be an alternative to eliminating apneas in evaluation of the optimal therapeutic level of CPAP in OSAS.

Adult↗