PubMed HealthSearch

Biomedical subjects

D Mahon

Publications and source records attributed to D Mahon.

8 recordsLinked to original sources

Measurement of cardiac output by automated single-breath technique, and comparison with thermodilution and Fick methods in patients with cardiac disease.

Accurate noninvasive methods are needed for determination of cardiac output. Current methods are generally complex or may be unreliable. A previously described method, based on absorption of acetylene gas during a constant exhalation that enables calculation of cardiac output by estimating pulmonary capillary circulation, is incorporated in a new, automated commercial product (SensorMedics 2200). In this study, cardiac output by single-breath acetylene blood flow measured with this device was compared with the standard thermodilution and direct Fick methods in 20 patients undergoing cardiac or pulmonary artery catheterization. Patients inhaled test gas mixture to total lung capacity and exhaled at a constant rate through an adjustable resistor. Lung volumes and noninvasive acetylene blood flow value were calculated automatically. Correlation between the automated single-breath technique and both thermodilution and Fick cardiac output determinations was very high (correlation coefficients were 0.90 and 0.92, respectively), regression slopes were close to identity (0.98 and 0.90), and bias (-0.39 and -0.79 liter/min) and precision (0.94 and 1.02) were good; when shunt correction was applied, bias was reduced to 0.06 and 0.35 liter/min, respectively. Rapid, accurate, noninvasive measurement of cardiac output was easily obtained using the automated device. This technique may have a wide applicability for noninvasive evaluation of patients with cardiac disease and for monitoring effects of therapeutic interventions.

Absorption

Intravascular ultrasound imaging in human peripheral and coronary arteries in vivo.

To determine the feasibility of intravascular ultrasound imaging in vivo, a miniaturized high frequency transducer catheter was introduced into human peripheral (n = 10) and coronary (n = 4) arteries. Cross-sectional ultrasound images were obtained from iliofemoral arteries in 10 patients using a 20 MHz transducer catheter (1.2 mm in diameter) and from coronary arteries in 4 patients using a 30 MHz transducer catheter 5 French size (Fr) following successful coronary angioplasty. Ultrasound images obtained from peripheral arteries showed a three-layered appearance (echo-reflective intima, echo-lucent media and echo-reflective adventitia) in the normal arteries. In diseased arteries, the location, amount and extent of atheromatous plaque were clearly documented. The arterial diameters measured by ultrasound closely correlated with the measurements by angiography (r = 0.91) in the peripheral arteries. Coronary angiograms obtained following balloon angioplasty revealed smooth edges at the dilatation sites without significant narrowing in all patients. However, a significant amount of residual atheromatous plaque was clearly observed on the ultrasound images at the previously dilated sites. Coronary dissection, which was identified as an echo-lucent area behind the plaque, was noted in 2 patients. Ultrasound images also revealed the presence of calcium in the plaque which was unrecognized on the angiograms in 3 patients. In addition, direct measurement of the lumen cross-sectional area was possible on the ultrasound images.(ABSTRACT TRUNCATED AT 250 WORDS)

Arteriosclerosis

Unrecognized stenosis by angiography documented by intravascular ultrasound imaging.

This report documents how intravascular ultrasound imaging was used to diagnose a short "napkin-ring" stenosis that was missed by coronary angiography. Intravascular ultrasound revealed a lumen of 2.6 x 2.5 mm in diameter and 5.0 mm2 in cross-sectional area, with a residual atheroma that occluded 63% of available cross-sectional area at the stenosis.

Angiography

Intravascular ultrasound imaging of human coronary arteries in vivo. Analysis of tissue characterizations with comparison to in vitro histological specimens.

BACKGROUND: Intravascular ultrasound imaging was performed in 27 patients after coronary balloon angioplasty to quantify the lumen and atheroma cross-sectional areas. METHODS AND RESULTS: A 20-MHz ultrasound catheter was inserted through a 1.6-mm plastic introducer sheath across the dilated area to obtain real-time images at 30 times/sec. The ultrasound images distinguished the lumen from atheroma, calcification, and the muscular media. The presence of dissection between the media and the atheroma was well visualized. These observations of tissue characterization were compared with an in vitro study of 20 human atherosclerotic artery segments that correlated the ultrasound images to histological preparations. The results indicate that high-quality intravascular ultrasound images under controlled in vitro conditions can provide accurate microanatomic information about the histological characteristics of atherosclerotic plaques. Similar quality cross-sectional ultrasound images were also obtained in human coronary arteries in vivo. Quantitative analysis of the ultrasound images from the clinical studies revealed that the mean cross-sectional lumen area after balloon angioplasty was 5.0 +/- 2.0 mm2. The mean residual atheroma area at the level of the prior dilatation was 8.7 +/- 3.4 mm2, which corresponded to 63% of the available arterial cross-sectional area. At the segments of the coronary artery that appeared angiographically normal, the ultrasound images demonstrated the presence of atheroma involving 4.7 +/- 3.2 mm2, which was a mean of 35 +/- 23% of the available area bounded by the media. CONCLUSIONS: Intravascular ultrasound appears to be more sensitive than angiography for demonstrating the presence and extent of atherosclerosis and arterial calcification. Intracoronary imaging after balloon angioplasty reveals that a significant amount of atheroma is still present, which may partly explain why the incidence of restenosis is high after percutaneous transluminal coronary angioplasty.

Angiography

Analysis of posttraumatic syndrome following a mild head injury.

Medical, financial and legal implications of prolonged disability after mild head injury are significant. In this study, researchers examined symptoms and psychosocial sequelae of head trauma three and six months after mild head injury in a group of 75 adult patients admitted to the trauma service of St. Anthony Hospital, Denver, Colorado. Results support the following conclusions: (1) nursing observation plays a key role in identification of patients at risk for posttraumatic syndrome; (2) early intervention may facilitate the recovery process; (3) support from family and significant others is an important aspect of recovery; and (4) as expressed by patients and family during follow-up interviews, education by nurses is an important factor in lowering anxiety and frustration during recovery. Data collected identify patients at risk for difficulties in recovery. Symptoms most frequently seen and average length of recovery were also addressed in the study.

Adolescent

Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro.

A prototype ultrasound imaging catheter was evaluated in vitro using 17 human atherosclerotic artery segments before and after balloon dilatation angioplasty. The catheter was 1.2 mm in diameter and incorporated a single 20-MHz ultrasound transducer to obtain cross-sectional images of the arterial lumen. In 15 of the 17 (88%) arteries, high quality images were obtained, which demonstrated clear demarcation between the lumen and the endothelium, the atheroma plaque, the muscular media, and the adventitia. Qualitative characteristics of plaque disruption, dissection, and residual flaps were readily visible. In addition, quantitative information about cross-sectional lumen area was obtained before and after balloon dilatation. The mean cross-sectional lumen area increased from 8.7 to 15.1 mm2 (p less than 0.01) following balloon dilatation. The lumen area measured from the ultrasound images following dilatation correlated closely with the area measured from histologic sections (r = 0.88). The results from this study indicate that a small-diameter ultrasound imaging catheter can be developed that will provide high-resolution qualitative and quantitative information during peripheral and coronary angioplasty.

Angioplasty, Balloon

The reproducibility of intravascular ultrasound imaging in vitro.

To determine which factors may affect the image quality when an intravascular ultrasound catheter is used in vivo, the influence of blood, temperature change, and contrast media were evaluated. In addition, to confirm the reproducibility of intravascular ultrasound imaging to measure cross-sectional lumen area, intraobserver and interobserver variability were determined. The findings indicated that ultrasound images in blood are mildly attenuated, that changes from room temperature to body temperature do not have a significant impact on the image quality, that contrast media attenuates the image intensity in a dose-dependent manner, and that the intravascular ultrasound imaging catheter provides a reproducible method for measuring arterial lumen area with excellent intraobserver and interobserver correlation.

Arteriosclerosis

Reducing specialty bed use.

Saint Joseph Hospital is a tertiary care teaching facility with 602 licensed beds. In 1992 it was noted that there was a significant rise in the use of specialty beds within the hospital. Guidelines for selection, initiation, and termination were nonexistent. In an effort to reduce high costs associated with specialty bed use a study was conducted to determine appropriate selection criteria and monitor patient outcomes.

Beds