PubMed Health⌕ Search

Biomedical subjects

D Mantini

Publications and source records attributed to D Mantini.

9 recordsLinked to original sources

Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis.

The simultaneous recording of EEG and fMRI is a promising method for combining the electrophysiological and hemodynamic information on cerebral dynamics. However, EEG recordings performed in the MRI scanner are contaminated by imaging, ballistocardiographic (BCG) and ocular artifacts. A number of processing techniques for the cancellation of fMRI environment disturbances exist: the most popular is averaged artifact subtraction (AAS), which performs well for the imaging artifact, but has some limitations in removing the BCG artifact, due to the variability in cardiac wave duration and shape; furthermore, no processing method to attenuate ocular artifact is currently used in EEG/fMRI, and contaminated epochs are simply rejected before signal analysis. In this work, we present a comprehensive method based on independent component analysis (ICA) for simultaneously removing BCG and ocular artifacts from the EEG recordings, as well as residual MRI contamination left by AAS. The ICA method has been tested on event-related potentials (ERPs) obtained from a visual oddball paradigm: it is very effective in attenuating artifacts in order to reconstruct clear brain signals from EEG acquired in the MRI scanner. It performs significantly better than the AAS method in removing the BCG artifact. Furthermore, since ocular artifacts can be completely suppressed, a larger number of trials is available for analysis. A comparison of ERPs inside the magnetic environment with those obtained out of the MRI scanner confirms that no systematic bias in the ERP waveform is produced by the ICA method.

Adult↗

Performance comparison of independent component analysis algorithms for fetal cardiac signal reconstruction: a study on synthetic fMCG data.

Independent component analysis (ICA) algorithms have been successfully used for signal extraction tasks in the field of biomedical signal processing. We studied the performances of six algorithms (FastICA, CubICA, JADE, Infomax, TDSEP and MRMI-SIG) for fetal magnetocardiography (fMCG). Synthetic datasets were used to check the quality of the separated components against the original traces. Real fMCG recordings were simulated with linear combinations of typical fMCG source signals: maternal and fetal cardiac activity, ambient noise, maternal respiration, sensor spikes and thermal noise. Clusters of different dimensions (19, 36 and 55 sensors) were prepared to represent different MCG systems. Two types of signal-to-interference ratios (SIR) were measured. The first involves averaging over all estimated components and the second is based solely on the fetal trace. The computation time to reach a minimum of 20 dB SIR was measured for all six algorithms. No significant dependency on gestational age or cluster dimension was observed. Infomax performed poorly when a sub-Gaussian source was included; TDSEP and MRMI-SIG were sensitive to additive noise, whereas FastICA, CubICA and JADE showed the best performances. Of all six methods considered, FastICA had the best overall performance in terms of both separation quality and computation times.

Algorithms↗

Optimal filter design for shielded and unshielded ambient noise reduction in fetal magnetocardiography.

The greatest impediment to extracting high-quality fetal signals from fetal magnetocardiography (fMCG) is environmental magnetic noise, which may have peak-to-peak intensity comparable to fetal QRS amplitude. Being an unstructured Gaussian signal with large disturbances at specific frequencies, ambient field noise can be reduced with hardware-based approaches and/or with software algorithms that digitally filter magnetocardiographic recordings. At present, no systematic evaluation of filters' performances on shielded and unshielded fMCG is available. We designed high-pass and low-pass Chebychev II-type filters with zero-phase and stable impulse response; the most commonly used band-pass filters were implemented combining high-pass and low-pass filters. The achieved ambient noise reduction in shielded and unshielded recordings was quantified, and the corresponding signal-to-noise ratio (SNR) and signal-to-distortion ratio (SDR) of the retrieved fetal signals was evaluated. The study regarded 66 fMCG datasets at different gestational ages (22-37 weeks). Since the spectral structures of shielded and unshielded magnetic noise were very similar, we concluded that the same filter setting might be applied to both conditions. Band-pass filters (1.0-100 Hz) and (2.0-100 Hz) provided the best combinations of fetal signal detection rates, SNR and SDR; however, the former should be preferred in the case of arrhythmic fetuses, which might present spectral components below 2 Hz.

Algorithms↗

A method for the automatic reconstruction of fetal cardiac signals from magnetocardiographic recordings.

Fetal magnetocardiography (fMCG) allows monitoring the fetal heart function through algorithms able to retrieve the fetal cardiac signal, but no standardized automatic model has become available so far. In this paper, we describe an automatic method that restores the fetal cardiac trace from fMCG recordings by means of a weighted summation of fetal components separated with independent component analysis (ICA) and identified through dedicated algorithms that analyse the frequency content and temporal structure of each source signal. Multichannel fMCG datasets of 66 healthy and 4 arrhythmic fetuses were used to validate the automatic method with respect to a classical procedure requiring the manual classification of fetal components by an expert investigator. ICA was run with input clusters of different dimensions to simulate various MCG systems. Detection rates, true negative and false positive component categorization, QRS amplitude, standard deviation and signal-to-noise ratio of reconstructed fetal signals, and real and per cent QRS differences between paired fetal traces retrieved automatically and manually were calculated to quantify the performances of the automatic method. Its robustness and reliability, particularly evident with the use of large input clusters, might increase the diagnostic role of fMCG during the prenatal period.

Algorithms↗

Automatic detection of cardiac waves on fetal magnetocardiographic signals.

Fetal magnetocardiography (fMCG) provides fetal cardiac traces useful for the prenatal monitoring of fetal heart function. In this paper, we describe an analytical model (ACWD) for the automatic detection of cardiac waves boundaries that works on fetal signals reconstructed from fMCG by means of independent component analysis. ACWD was validated for 45 healthy and 4 arrhythmic fetuses ranging from 22 to 37 weeks; ACWD outcomes were compared with the estimates of three independent investigators. Descriptive statistics were used to assess correspondence between the outcomes of the automatic and manual approaches. The parametric two-tailed Pearson correlation test (alpha=0.01) was employed to quantify, by means of the coefficients of determination, the amount of common variation between the sequences of intervals quantified automatically and manually. ACWD performances on short and long rhythm strips were investigated. ACWD demonstrated to be a robust tool providing dependable estimates of cardiac intervals and their variability during the third gestational trimester also in case of fetal arrhythmias. SNR and stability of fetal traces were the factors limiting ACWD performances. ACWD computation time, which was approximately 1:600 with respect to the manual procedure, was comparable with the time required for fCTI estimation on averaged beats.

Algorithms↗

Simultaneous monitoring of separate fetal magnetocardiographic signals in twin pregnancy.

Fetal magnetocardiography (fMCG) allows the non-invasive recording of fetal cardiac electrical activity with increasing efficacy as gestation progresses. Many reports on the successful extraction of reliable fetal magnetocardiographic traces in singleton pregnancies exist in the literature, whereas there is only one report on the reconstruction of averaged fetal cardiac signals obtained in a twin pregnancy with the use of a double sensor array system. In this paper, we aimed at assessing the effectiveness of an ICA-based procedure to reconstruct the time course of fetal cardiac signals recorded with a single-shot multi-channel fMCG device in an uncomplicated twin pregnancy at 27 weeks. The evaluation of heart rate and beats synchronicity permitted the differentiation of fetal components; the quality of reconstructed fetal signals allowed visual inspection on single cycles and the simultaneous monitoring of separate fetal heart rate patterns. The proposed technique might be applied in twin pregnancies not only to characterize fetal arrhythmias, but also in all cases of discordant fetal growth, either in the case of intra-uterine growth retardation affecting one fetus, or in the case of twin-twin transfusion syndrome, a life-threatening condition where both fetuses are at risk of heart failure.

Adult↗

Integrated software suite for magnetocardiographic data analysis--a proposal based on an interactive programming environment.

OBJECTIVES: This paper describes an integrated software suite (ISS) for the processing of magnetocardiographic (MCG) recordings obtained with super-conducting multi-channel systems having different characteristics. We aimed to develop a highly flexible suite including toolboxes for current MCG applications, organized consistently with an open architecture that allows function integrations and upgrades with minimal modifications; the suite was designed for the compliance not only of physicists and engineers but also of physicians, who have a different professional profile and are accustomed to retrieve information in different ways. METHODS: The MCG-ISS was designed to work with all common graphical user interface operative systems. MATLAB was chosen as the interactive programming environment (IPE), and the software was developed to achieve usability, interactivity, reliability, modularity, expansibility, interoperability, adaptability and graphics style tailoring. Three users, already experienced in MCG data analysis, have intensively tested MCG-ISS for six months. A great amount of MCG data on normal subjects and patients was used to assess software performances in terms of user compliance and confidence and total analysis time. RESULTS: The proposed suite is an all-in-one analysis tool that succeeded in speeding MCG data analysis up to about 55% with respect to standard reference routines; it consequently enhanced analysis performance and user compliance. CONCLUSIONS: Those results, together with the MCG-ISS advantage of being independent on the acquisition system, suggest that software suites like the proposed one could uphold a wider diffusion of MCG as a diagnostic tool in the clinical setting.

Diagnosis, Computer-Assisted↗

Time course reconstruction of fetal cardiac signals from fMCG: independent component analysis versus adaptive maternal beat subtraction.

M-mode and pulsed Doppler echocardiography, cardiotocography and transabdominal fetal ECG are available in clinical practice to monitor fetal cardiac activity during advancing gestation, but none of these methods allows the direct measurement of morphological and temporal parameters for fetal rhythm assessment. Fetal magnetocardiograms (fMCGs) are noninvasive recordings of magnetic field variations associated with electrical activity of the fetal heart obtained with superconducting sensors positioned over the maternal abdomen inside a shielded room. Because of maternal cardiac activity, fMCGs are contaminated by maternal components that need to be eliminated to reconstruct fetal cardiac traces. The aim of the present work was to use two methods working in the time domain, an independent component analysis algorithm (FastICA) and an adaptive maternal beat subtraction technique (AMBS), for the retrieval of fetal cardiac signals from fMCGs. Detection rates of both methods were calculated, and FastICA and AMBS performances were compared in the context of clinical applications by estimating several temporal and morphological characteristics of the retrieved fetal traces, such as the shape and duration P-QRS-T waves, arrhythmic beat detection and classification, and noise reduction. Quantitative and qualitative comparison produced figures that always suggested that FastICA was superior to AMBS from the perspective of clinical use of the recovered fetal signals.

Adult↗

Fetal magnetocardiographic mapping using independent component analysis.

Fetal magnetocardiography (fMCG) is the only noninvasive technique allowing effective assessment of fetal cardiac electrical activity during the prenatal period. The reconstruction of reliable magnetic field mapping associated with fetal heart activity would allow three-dimensional source localization. The efficiency of independent component analysis (ICA) in restoring reliable fetal traces from multichannel fMCG has already been demonstrated. In this paper, we describe a method of reconstructing a complete set of fetal signals hidden in multichannel fMCG preserving their correct spatial distribution, waveform, polarity and amplitude. Fetal independent components, retrieved with an ICA algorithm (FastICA), were interpolated (fICI method) using information gathered during FastICA iterations. The restored fetal signals were used to reconstruct accurate magnetic mapping for every millisecond during the average beat. The procedure was validated on fMCG recorded from the 22nd gestational week onward with a multichannel MCG system working in a shielded room. The interpolated traces were compared with those obtained with a standard technique, and the consistency of fetal mapping was checked evaluating source localizations relative to fetal echocardiographic information. Good magnetic field distributions during the P-QRS-T waves were attained with fICI for all gestational periods; their reliability was confirmed by three-dimensional source localizations.

Algorithms↗