PubMed Health⌕ Search

Biomedical subjects

D Meacham

Publications and source records attributed to D Meacham.

2 recordsLinked to original sources

A cardiac evoked response algorithm providing threshold tracking: a North American multicenter study. Clinical Investigators of the Microny-Regency Clinical Evaluation Study.

The purpose of this study was to evaluate a pacing system using the recognition of cardiac evoked response for the automatic adjustment of pacing output. Patients were prospectively followed after primary implantation of VVIR pacemakers using AutoCapture (St. Jude Medical CRMD). Sensing and pacing thresholds, polarization signal, evoked response, and AutoCapture performance were evaluated with serial visits and 24-hour Holter monitoring. Three hundred ninety-eight patients (mean age 71 +/- 15 years) were followed for an average duration of 1 year (3 days-1.75 years) with the algorithm functional in > 90% of patients. Backup pacing in the event of exit block was confirmed in all patients. Pacing thresholds remained stable at 0.89 +/- 0.34 V with a pulse width of 0.31 ms (with chronic output autoset at 0.3 V above the actual threshold). Evoked response exhibited a small but statistically significant increase with time (8.92 mV at implant, 9.60 mV at 12 months), however, this finding did not result in any change in AutoCapture function during our follow-up period. The polarization signal remained stable with minimal variation (1.12 mV at implant, 1.18 at 12 months). No clinical adverse events were observed using the AutoCapture algorithm. In this initial experience with the AutoCapture algorithm the evoked response and polarization measurements remained adequate, allowing the system to function in the majority of patients with safe, low output pacing. High energy backup pacing provided an added safety feature over fixed output devices in cases of unexpected threshold rises. Longer follow-up is required for continued long-term validation of the algorithm.

Aged↗

Evaluation of warning arrhythmias before paroxysmal ventricular tachycardia during acute myocardial infarction in man.

In order to determine the relationship of paroxysmal ventricular tachycardia (PVT) to any antecedent (premonitory) ventricular arrhythmias during the early phases of acute myocardial infarctions, 24-hour Holter monitoring was begun on 52 male patients an average of 12.6 hours after the onset of prolonged chest pain that was documented as acute infraction. Twenty-four patients had PVT and 28 did not. We analyzed in detail the incidence of frequency of premature ventricular complexes (PVCs), prematurity and pairing during the 10 minutes immediately preceding PVT from a continuous 10-minute rhythm strip. There was no positive correlation between PVT and the number or complexity of PVCs in the 10 minutes immediately before ventricular tachycardia. These findings suggest that there is no consistent pattern or frequency of ventricular arrhythmia that could be identified as premonitory for PVT during the immediate pre-PVT period, even during the acute phase of myocardial infarction in man.

Acute Disease↗