Performance assessment of the Terry Fox jogging prosthesis for above-knee amputees.

The Terry Fox jogging (TFJ) prosthesis was developed at Chedoke-McMaster Hospital to alleviate the asymmetric jogging pattern experienced by above-knee amputees when attempting to jog with conventional walking prostheses. This prosthesis features a spring-loaded, telescoping shank designed to eliminate any vaulting action and control the trunk motion during stance. The spring is intended to attenuate the impact forces and release its stored energy at push-off to provide momentum transfer to the jogger. This prosthesis was comprehensively assessed in the gait laboratory, by evaluating the kinematics, energy and power flow patterns of an above-knee amputee jogger wearing the TFJ prosthesis. Included in the assessment is the ability of the prosthesis to satisfy a set of relevant design criteria that have been established from non-amputee jogging patterns. An increased swing phase time for the prosthetic limb and the need to have the knee hyperextended throughout the stance phase contributed to an asymmetric jogging style. The telescoping action did lower the amputee's centre of mass, thereby reducing the vaulting effect. However, the spring only imparted a lifting action to the jogger and the ground reaction forces were double those of a non-amputee jogger. These findings clearly indicate a need to redesign the TFJ prosthesis and are being incorporated in the design of a new physiological jogging prosthesis.

Adult

Presurgical finite element simulation of scoliosis correction.

For surgical correction of scoliotic spinal deformity, internal fixation systems apply lateral and distractive corrective forces. In order to gain maximal correction, a finite--element analysis of the spinal deformity correction technique has been carried out preoperatively, after first employing the spinal deformity correction finite--element model to determine the in vivo spinal stiffness. The presurgical analysis also gives us an appreciation of how the parameters of deformity, stiffness and corrective forces jointly contribute to the value of the correction index. The paper presents the methodology and clinical application. It also summarizes the results for ten patients, whereby the efficacy of presurgical analysis is assessed by comparing the corrective index values by presurgical simulation with the surgical results for equivalent levels of corrective forces.

Adolescent

Microcomputerized on-line evaluation of heart rate variability power spectra in humans.

The heart rate variability power spectra is computed using an on-line microcomputer system. In normal subjects (n = 10), standing and post-exercise states demonstrated statistically significant increases (p less than 0.05) in the peak power at 0.1 Hz. During exercise, the peak power at 0.1 Hz was reduced significantly (p less than 0.05). In patients with myocardial infarction, either the peak at 0.1 Hz or the peak associated with breathing frequency was augmented. Our system is mobile and is useful especially when on-line heart rate variability power spectra are required in experimental or clinical situations.

Adult

Statistical pattern classification of clinical brainstem auditory evoked potentials.

The brainstem auditory evoked potentials (BAEPs) recorded in the neurological clinic were classified using the Bayes classifier (BC) and Fisher's linear discriminant function (FLD). The latencies of initial five peaks, interpeak intervals were examined for optimum features to develop classifiers. The accuracy of classification was 85.3% when absolute latencies of peaks III, IV and V were used as features. The BC gave better performance than FLD, indicating that second order statistics of BAEPs for normal and pathological classes are different. The results of this study indicate that latencies alone give enough information for recognizing normal from pathological BAEPs, using physician's evaluation of BAEPs as the reference.

Adult

Biomechanical basis of optimal scoliosis surgical correction.

For an optimal approach to surgical correction of scoliosis, it was deemed desirable to biomechanically simulate the set of corrective forces applied by alternative internal fixation systems, so as to determine and apply the internal fixation system producing the best correction under safe levels of forces applied by the fixation systems to the spinal structures. To this end, we have developed, and presented here, (1) a spinal finite-element model relating the applied corrective forces to the corrected spinal configurations, (2) a method for determining the stiffness of the patient's spine prior to surgery, (3) computerized finite-element analysis simulation of alternative internal correction-fixation systems, so as to determine the most efficacious system, (4) instrumentations for surgically implementing the recommendations of the surgical simulation analysis and (5) comparisons of the model-simulated and surgically-obtained corrected spinal configurations. These procedures together constitute the biomechanical foundations of scoliosis surgical correction.

Biomechanical Phenomena

Spectral analysis of heart rate variability following human heart transplantation: evidence for functional reinnervation.

To determine the status of innervation in long-term human donor allografts, the power spectrum of heart rate variability was analysed in 9 post-transplant patients and 7 healthy control subjects. The mean post-transplant follow-up was 17.8 months (range: 2-37 months). Continuous ECG signals were recorded throughout a 15-min rest period. An R-R interval tachogram was generated and an autoregressive model using linear predictive coding, was applied to the heart rate variability data. In 8 transplant patients the frequency oscillations were irregular, broad based and widely dispersed from 0 to 1 Hz. The patterns resembled white noise and were consistent with dissociation of the donor allograft from the recipient's central nervous system. In contrast, one patient displayed a heart rate variability spectrum indistinguishable from that of control subjects. This pattern contained two distinct spectral bands; one corresponding to the patient's respiratory rate at 0.2 Hz and a low frequency Mayer wave at 0.1 Hz. Atropine abolished the respiratory (vagal) peak. Except for this patient's post-transplant time (33 months compared to the group mean of 17.6 months), there were no clinical characteristics which distinguished this patient from the others. While the mean heart rate for the remaining 8 allografts was significantly higher than controls (95.3 vs 64.5 bt/min; P less than 0.001) the standard deviation of heart rate variability for the 8 patients was significantly narrower than controls (0.7 vs 4.86; P less than 0.01). The variance of heart rate for the patient with the normal power spectrum was fourfold greater than the mean SD of the other transplant patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Radiological changes in rheumatoid arthritis: measurement of area of juxta-articular bone as outcome event in clinical therapeutic trials of antirheumatic drugs.

A high degree of intra - and inter - rater reproducibility was obtained in measurement of a standardized area of the head of the first right metacarpal using a precision digitizer. This instrument had an accuracy for every point digitized of 0.127 mm. Intra-rater difference between readings at approximately a month's interval showed no significant differences. The method is reasonably simple to perform and is applicable to small joints such as the proximal interphalangeal joints. The method may prove useful in following progression of joint damage in rheumatoid arthritis.

Anti-Inflammatory Agents

Power spectrum of heart rate variability: a non-invasive test of integrated neurocardiac function.

Under steady state conditions, frequency specific oscillations in the heart rate record reflect beat-to-beat autonomic control of sinus node activity. Using an autoregressive model, samples (2.5 min) of continuous ECG records were analyzed in 36 healthy young adults during supine rest (45 min), orthostatic stress and controlled respiration. In the supine state, constancy of heart rate was achieved (mean HR 62.8 bt/min +/- 4.88 SD). However, the 0.1 Hz peak spectral power varied considerably: average coefficient of variation was 34% compared to only 8% for heart rate. When breathing rates were synchronized to a metronome there was a small insignificant decrease in the peak power at 0.1 Hz compared to spontaneous respiration. Standing produced a significant increase in the peak power at 0.1 Hz especially during synchronized breathing. There was a maximum increase in the low frequency (0.1 Hz) peak power of 40 (bt/min)2. Hz-1 at a controlled breathing frequency of 0.25 Hz in the standing compared to supine position. The data show that reproducibility of the power spectrum heart rate variability is best achieved at controlled but physiologic respiratory rates and, preferably, in the upright position.

Adult

Heart rate variability power spectrogram as a potential noninvasive signature of cardiac regulatory system response, mechanisms, and disorders.

This paper attempts to provide evidence that the heart rate variability power spectrum (HRVPS) reflects the presence of neural control of cardiac regulation. A normal individual is seen to have a characteristic HRVPS (comprising a 0.1-Hz peak and a respiratory peak at 0.25-0.34 Hz), which is altered in a predictable manner in response to orthostatic stress and exercise, while in two patients with autonomic neuropathy, the HRVPS failed to demonstrate such a characteristic alteration in response to orthostatic stress. Postinfarct HRVPS signatures were studied in two patients with anterior and inferior infarcts so as to lend insight using non-invasive means into both the healing process and the dominant deliterious sympathetic or protective vagal tone due to the infarct. When subjects with transplanted hearts were studied, their HRVPS did not exhibit the characteristic pattern of a normal individual; rather, the HRVPS energy was spread over a wider and higher frequency range. However, one of the transplanted patients surprisingly but consistently revealed the characteristic HRVPS; the post-transplant time at the time of the study was 33 months and the patient had the typically high resting heart rate of a transplant recipient but a wide standard deviation like that of a normal individual. This could be the first noninvasively demonstrated evidence in humans of reinnervation of a transplanted heart. Thus, the HRVPS constitutes a simple non-invasive method to assess cardiac neuroregulatory response and disorders and it is proposed that it be referred to as the heart rate variability cardiogram (HRVC).

Adult

Power spectral analysis of normal and pathological brainstem auditory evoked potentials.

The brainstem auditory evoked potential (BAEP) recording has become a powerful investigational tool in neurological diagnosis. The BAEPs of patients have different latencies and morphologies when compared to those of normals. In this paper the power spectra (PS) of BAEPs of 21 normals, 17 patients with multiple sclerosis (MS) and 12 patients with head injury (HI) computed by Blackman-Tukey (BT) and Maximum Entropy (ME) methods are examined for their frequency composition. Three major peaks appear at approximately 170 Hz, 520 Hz and 950 Hz in PS of normal BAEPs. The average power contained in the frequency bands spread around these frequency bands for BAEPs of patients differed significantly (P less than 0.05) from those of normal BAEPs. The peaks observed in ME spectra were found to match those computed using BT method. The model order for representing both normal and patient BAEPs is greater than 40 and data compression afforded by modelling the BAEPs is of the order of 5:1.

Adolescent

Intrinsic indices of the left ventricle as a blood pump in normal and infarcted left ventricles.

To assess the left ventricle as a blood pump, data are collected from contrast angiograms and analysed by computer, using two-dimensional finite element analysis, to provide instantaneous distributions of intra-LV flow and differential pressure during the diastolic and ejection phases. Characteristic indices are derived for normal and infarcted LVs, and for cases before and after administration of nitroglycerin. These indices may be used to assess the degree and nature of dysfunction in coronary artery disease.

Biomedical Engineering

Mechanics of left ventricular aneurysm.

When a coronary artery is significantly occluded, the left ventricular myocardial segment, which is perfused by that coronary artery, will become ischaemic and even irreversibly infarcted. An acute infarct has very low stiffness and if it involves the entire wall there is a risk of rupture; however, in the absence of such a critical situation, fibrous tissue is laid into the infarcted myocardial segment. Such an infarcted fibrotic myocardial segment will not be able to contract, and so generate tensile stress. The surrounding intact myocardium will contract and generate wall stress, thereby developing a high intra-chamber systolic pressure; the chronically infarcted and fibrotic segment will have to sustain this high chamber pressure. Its loss of contractility and the resulting reduced systolic stiffness relative to the intact segment, will cause it to deform into a bulge; this is an aneurysm. When a left ventricular chamber with an aneurysm contracts during the systolic phase, some blood also goes into the aneurysm, and this decreases the stroke volume; since the aneurysm wall is passive, stagnant blood flow prevails in the aneurysm itself, which in turn can give rise to the formation of a mural thrombus. These serious consequences provide a justification for the analysis of an infarcted left ventricular chamber, in order to predict the size of the aneurysmic bulge. Such an analysis is presented in this paper. To determine the left ventricular wall deformation, and the stress arising from infarction of a wall segment (which leads to a ventricular aneurysm) the left ventricle is modelled here as a pressurized ellipsoidal shell. Deformations of infarcted wall segments are computed for several damaged wall-thicknesses in left ventricles of different shapes. The analysis involves a derivation of equations for wall-stress equilibrium with the chamber pressure, and myocardial incompressibility before and after infarct formation. The equations are solved by the Newton-Raphson method (using elliptical integrals of the first and second kind). Of significance are the prognostic implications of the results, presented in the form of graphs, showing the dependence of tensile stress and the bulge of infarcted wall-segments, on the extent of damaged wall-thickness and the angle of infarct. Scaled illustrations of the bulge shapes, for various degrees of infarcts, are provided. The results indicate that for rupture of the ventricle, the percentage of infarcted wall-thickness and the shape of the ellipsoidal left ventricular chamber play more dominant roles than the angle-of-damage, or the extent of the infarct.

Biomechanical Phenomena

Biomechanical analysis and simulation of scoliosis surgical correction.

In scoliosis, presurgical determination of each patient's segmental spinal stiffness will permit model simulation of the surgical correction. It also permits calculation of the optimal combination of corrective forces applied to the spine by the internal fixation system. This information can help to optimize the surgical procedure, especially if calculated forces and corrections can be monitored during surgery. To this end, a finite-element model of the spine has been developed that determines segmental stiffness from data of spinal geometries, derived from the radiographs of the patient, taken with incremental distraction applied to the head. On this model, custom-tailored combinations of corrective forces are applied incrementally until optimal correction is obtained, for safe levels of distraction and lateral forces. With variations in the computer software, any desired surgical instrumentation system can be simulated. Instrumented distractor and compression forceps have been fabricated to monitor surgical forces and displacements, and to permit eventual implementation of the model recommendations. Comparison of surgically acquired correction with that predicted by the model is then carried out. Data on complete analysis of two cases of idiopathic scoliosis are presented. They show significant variations in segmental and interpatient stiffness values, and how spinal stiffness governs the amount of correction gained by the nature and magnitude of corrective forces.

Adult

Thrombogenetic studies of bioprosthetic heart valve surfaces. I. In vitro platelet adhesion in a static system.

Contact angle measurements, histological examinations and platelet adhesion tests on native and glutaraldehyde-treated porcine aortic valve leaflets, are reported. Contact angles measured with water or saline on native and treated leaflets do not differ appreciably. Values of less than 10 degrees for both the dry and wet leaflets were observed. Histological examination of the native and fixed tissue surfaces was carried out with both optical and scanning electron microscopy. Native leaflet surfaces appeared to be smoother with longer and straighter fibres beneath the surface than treated leaflets. Platelet adhesion tests were performed with fresh, non-anticoagulated human whole blood as well as with platelet suspension. Static platelet adhesion tests were carried out by depositing droplets of blood on the test surface. The blood droplets were washed off after a contact time of 2 minutes for whole blood and up to 32 minutes for platelet suspension. The adhering platelets were microscopically observed and counted. The platelet density on the native leaflets was found to be significantly higher than on the treated tissues. However, the platelet density did not vary with glutaraldehyde concentration in the range from 0.2 to 1.0% (v/v).

Animals

Electrodiagnostic model for motor unit action potential (MUAP) generation.

The paper presents the development of inverse analysis of EMG, in terms of a Linear Prediction Coding (LPC) model and its parametric simulation of recorded single motor-unit action potential, for electrodiagnosis of neuromuscular disorders due to motor neuron degeneration, regeneration after lesion, myopathy, etc.

Action Potentials

Computer design synthesis of a below knee-Syme prosthesis.

A detailed design synthesis analysis of the BK Syme prosthesis is provided, to determine the socket's cutout orientation size and shape, cutout fillet shape, socket wall thickness distribution and the reinforced fiber distribution in the socket wall, for a minimally stressed structurally safe lightweight prosthesis. For analysis purpose, the most adverse socket loading is obtained at the push-off stage of gait; this loading is idealised as an axial in-plane loading on the bottom edge of the circular cylindrical socket shell whose top edge is considered fixed. Finite element stress analysis of the socket shell (with uniform and graded wall thickness) are performed for various orientations of the cutout and for various types of corner fillets. A lateral cutout with a streamline fillet is recommended. The wall material (i.e., thickness) distribution is determined so as to minimise the stresses, while ensuring that the wall material's stress limits are not exceeded. For such a maximally-stressed lightweight socket shell, the panels in the neighbourhood of the cutout are checked to ensure that they do not buckle under their acquired stresses. A fiber-reinforced laminated composite socket shell is also analysed, to recommend optimum variables in orientations and densities of reinforcing fibers.

Ankle