PubMed Health⌕ Search

Biomedical subjects

D N Levin

Publications and source records attributed to D N Levin.

44 records · Page 3Linked to original sources

Effects of trifluoperazine on function and structure of toad urinary bladder. Role of calmodulin vasopressin-stimulation of water permeability.

Calcium ion plays a major regulatory role in many hormone-stimulated systems. To determine the site of calcium's action in the toad urinary bladder, we examined the effect of trifluoperazine, a compound that binds specifically to the calcium binding protein, calmodulin, and thereby prevents activation of enzymes by the calcium- calmodulin complex. 10 microM trifluoperazine inhibited vasopressin stimulation of water flow, but did not alter vasopressin's effects on urea permeability or short-circuit current. Trifluoperazine also blocked stimulation of water flow by cyclic AMP and methylisobutylxanthine, implying a "postcyclic AMP" site of action. Consistent with these results, trifluoperazine did not decrease epithelial cyclic AMP content or the cyclic AMP-dependent protein kinase activity ratio. Assay of bladder epithelial supernate demonstrated calmodulin-like activity of 1.5 U/microgram protein. Morphologic studies of vasopressin-treated bladders revealed that trifluoperazine did not alter the volume density of cytoplasmic microtubules or significantly decrease the number of fusions between cytoplasmic, aggregate-containing, elongated vesicles and the luminal membrane. Nonetheless, the frequency of luminal membrane aggregates, structures that correlate well with luminal membrane water permeability, was decreased by greater than 50%. Thus, trifluoperazine appears to inhibit the movement of intramembranous particle aggregates from the fused intracellular membranes to the luminal membrane, perhaps by blocking an effect of calcium on microfilament function.

3',5'-Cyclic-AMP Phosphodiesterases↗

Visualization of MR angiographic data with segmentation and volume-rendering techniques.

Novel image processing and computer graphics techniques were developed to create three-dimensional (3D) models of vasculature from magnetic resonance (MR) angiographic images of the head or neck. Region growing was used to produce a mask that isolated the vascular signal in the MR angiographic data. The masked images were subjected to gradient-shaded volume rendering to create 3D views of the vasculature. The computer-derived model of intracranial vasculature was then merged with a 3D model of brain parenchyma derived from a set of MR images. The combined display of vascular and gyral anatomy may be useful for neurosurgical planning.

Brain↗

MR imaging with spatially variable resolution.

In some situations it may be advantageous to produce "locally focused" magnetic resonance images that have nonuniform spatial resolution matching the expected local rate of spatial variation in the object. Because such an image has fewer pixels than a conventional image with uniformly high resolution, it can be reconstructed from fewer signals, acquired in less time. This can be done by using a highly convergent representation of the image as a sum of orthonormal functions with slow (fast) spatial variation in relatively homogeneous (heterogeneous) parts of the object. Since this series is shorter than a conventional truncated Fourier series, its terms can be calculated from a subset of the usual array of phase-encoded signals. The optimal choice of these phase encodings, which are usually scattered nonuniformly in k space, results in minimization of noise in the reconstructed image. The technique is illustrated by applying it to simulated data and to data from images of phantoms.

Computer Simulation↗

Functional mapping of human motor cortical activation with conventional MR imaging at 1.5 T.

A conventional 1.5-T magnetic resonance (MR) imager was used to detect signal intensity changes on T2*-weighted images of human motor and sensory cortices during performance of hand and tongue movements. Narrow receiver bandwidths were used to improve the signal-to-noise ratio. Protocols consisting of baseline, motor task, rest, and second motor task periods were performed by nine volunteers. Two-dimensional cross correlation was applied to correct in-plane translation and rotation of the head during the imaging session before the control images were subtracted from the task images. Measurements obtained during finger movement tasks indicated a 3%-8% increase in signal intensity near the contralateral central sulcus and smaller ipsilateral signal intensity increases. Bilateral signal intensity increases were also observed during tongue movement studies. A retrospective image registration technique was used to map the signal changes onto conventional anatomic images, which were used to create integrated three-dimensional models of brain structure and function. These integrated images showed that the highest signal intensity due to hand movement was near the putative central sulcus.

Adult↗

Retrospective registration of X-ray angiograms with MR images by using vessels as intrinsic landmarks.

Conventional x-ray angiography (XRA) images are projections of the vasculature with high spatial and temporal resolution, while magnetic resonance (MR) angiography (MRA) and MR imaging data show the three-dimensional locations of vessels relative to brain parenchyma. The authors have developed a retrospective method of registering these studies, which makes it practical to produce multimodality displays of this complementary information. Registration was performed by matching vessels seen on both XRA and MRA images. First, the authors determined the coordinates of the center lines of a few "landmark" vessels on the XRA image and the three-dimensional locations of the corresponding intraluminal voxels in the MRA volume. Registration was performed by rotating and translating the MRA-MR imaging volume until the perspective projection of the MRA landmark vessels matched the corresponding vessel center lines on the XRA image. Experiments with phantoms and patients indicated that the two studies were registered with an average error of less than 2 mm. A linked-cursor display was developed to show correspondence between points on the registered XRA and MRA-MR images.

Angiography↗

Locally focused MRI of interventions.

Certain interventional MR procedures would benefit from T2-weighted imaging because of the sensitivity of T2-weighted images to tissue damage and target lesion contrast. To acquire such images with reasonable temporal resolution, a single-shot acquisition should be used because of the inherently long TR needed for T2 weighting. Unfortunately, most scanners require long readout times (eg, greater than 150 msec) and high bandwidths (eg, greater than 120 kHz) to perform conventional single-shot imaging with high spatial resolution. The resulting images are thus degraded by unacceptable artifacts and noise levels. This study illustrates how to create locally focused MR images that have high spatial resolution in a region of interest and lower spatial resolution elsewhere in the image. Because these images can be created from sparse k-space data, a scanner with modest gradients (eg, 10 mT/m maximal amplitude, 500 microsec minimal rise time) can acquire them after a single excitation with relatively short readout time and low bandwidth. This technique may make it practical to monitor interventions with T2-weighted imaging. The method was illustrated by reconstructing dynamic changes, which were simulated experimentally by moving objects in the vicinity of a normal human head.

Brain↗

Retrospective fusion of radiographic and MR data for localization of subdural electrodes.

Prior to epilepsy surgery, subdural electrodes are often implanted and monitored for a few days to identify the focus of abnormal electrical activity. During the implantation and subsequent brain resection, there may be uncertainty about the exact location of the electrodes with respect to features of brain anatomy such as specific gyral convolutions or lesions. In experiments with a phantom and patients, implanted electrodes were imaged with multiplanar skull radiographs (or CT scans). After retrospective registration with preimplantation MR data, the electrodes were mapped from these studies onto an MR-derived three-dimensional brain model. The resulting multimodality displays showed the relationship of the electrodes to brain anatomy. In one patient the position of each electrode with respect to a metabolic lesion was also displayed by mapping preimplantation PET data onto the same brain model. This new display of electrode positions may strengthen the interpretation of subdural electrical recordings and thereby reduce uncertainty in planning the resection of epileptic tissue.

Adult↗