PubMed HealthSearch

Biomedical subjects

D N Slatkin

Publications and source records attributed to D N Slatkin.

At least 19 recordsLinked to original sources

Neuropathology of ablation of rat gliosarcomas and contiguous brain tissues using a microplanar beam of synchrotron-wiggler-generated X rays.

Adult-rat-brain tissues display an unusually high resistance to necrosis when serially irradiated with parallel, thin slices of a microplanar (i.e., microscopically thin and macroscopically broad) beam of synchrotron-wiggler-generated, approx. 35-120 keV (median approx. 50 keV) Gd-filtered X rays at skin-entrance absorbed doses of 312 to 5000 Gy per slice. Such microplanar beams were used to irradiate young adult rats bearing right frontocerebral 9L gliosarcomas (approx. 4 mm diameter), through a volume of tissue containing the tumor and contiguous brain tissue, either in a single array or in 2 orthogonally crossed arrays of tissue slices. Each array included 101 parallel microplanar slices, 100 microm center-to-center distance, each slice being approx. 25 microm wide and 12 mm high, with skin-entrance absorbed doses of 312.5 Gy or 625 Gy per slice. Compared with unirradiated controls with a median survival time of 20 days after tumor initiation, the median survival time was extended in irradiated rats by 139 days (625 Gy, crossed arrays), 96 days (312 Gy, crossed arrays) or 24 days (625 Gy, single array). The tumors disappeared in 22 of the 36 irradiated rats, 4/11 even after unidirectional microbeam irradiation. The extent and severity of radiation damage to the normal brain in rats with or without tumor was graded histopathologically. Correlation of those grades with radiation doses shows that loss of tissue structure was confined to beam-crossing regions and that only minor damage was done to zones of the brain irradiated unidirectionally.

Animals

Evaluation of carborane-containing porphyrins as tumour targeting agents for boron neutron capture therapy.

A number of carborane-containing porphyrins were administered to mice bearing subcutaneously transplanted mammary carcinomas. Administration was via serial intraperitoneal (i.p.) injections to assess their relative toxicities and tumour affinities. Three analogues of the natural porphyrin heme and four tetraphenylporphyrins (TPPs) were given at total doses of 78-245 micrograms g-1 body weight. The water-insoluble TPPs were less toxic to mice, and delivered greater amounts of boron to tumour than did the water-soluble TPPS and the heme analogues. One such compound, NiTCP-H, delivered more than 100 micrograms B g-1 to tumour tissue with a tumour:blood boron concentration ratio greater than 500:1 and a tumour: brain boron concentration ratio greater than 50:1, 4 days after the last of six i.p. injections given over 2 days. Another TPP analogue, NiTCP, delivered approximately 50 micrograms B g-1 to tumour with similar boron concentrations in normal tissues. Neither compound was toxic to mice at total doses of approximately 200 micrograms g-1 body weight. In contrast, the heme analogues were toxic and, with the exception of VCDP, delivered less boron to tumour than NiTCP and NiTCP-H. The two porphyrins with the greatest potential for application to boron neutron capture therapy (BNCT), NiTCP and NiTCP-H, yielded higher tumour:blood and tumour:brain boron concentration ratios in mice than could be achieved with p-boronophenylalanine (BPA) and sodium mercaptoundecahydrododecaborate (BSH), the compounds which are currently being used in clinical trials of BNCT in the treatment of glioblastoma. The boron delivered by each of the porphyrins tested remained in tumour tissue longer than did boron delivered by either BPA or BSH. The copper and nickel chelates of these porphyrins behave identically in vivo. The former offer the potential for imaging by 67Cu-mediated single photon emission computed tomography (SPECT) to aid BNCT treatment planning.

Animals

Biodistribution of boronophenylalanine in patients with glioblastoma multiforme: boron concentration correlates with tumor cellularity.

Boron-10 (10B) concentrations were measured in 107 surgical samples from 15 patients with glioblastoma multiforme who were infused with 95 atom% 10B-enriched p-boronophenylalanine (BPA) intravenously for 2 h just prior to surgery at doses ranging from 98 to 290 mg BPA/kg body weight. The blood 10B concentration reached a maximum at the end of the infusion (ranging from 9.3 to 26.0 microg 10B/g) and was proportional to the amount of BPA infused. The boron concentrations in excised tumor samples ranged from 2.7 to 41.3 microg 10B/g over the range of administered BPA doses and varied considerably among multiple samples from individual patients and among patients at the same BPA dose. A morphometric index of the density of viable-appearing tumor cells in histological sections obtained from samples adjacent to, and macroscopically similar to, the tumor samples used for boron analysis correlated linearly with the boron concentrations. From that correlation it is estimated that 10B concentrations in glioblastoma tumor cells were over four times greater than concurrent blood 10B concentrations. Thus, in the dose range of 98 to 290 mg BPA/kg, the accumulation of boron in tumor cells is a linear function of BPA dose and the variations observed in boron concentrations of tumor specimens obtained surgically are largely due to differences in the proportion of nontumor tissue (i.e. necrotic tissue, normal brain) present in the samples submitted for boron analysis. The tumor:blood 10B concentration ratio derived from this analysis provides a rationale for estimating the fraction of the radiation dose to viable tumor cells resulting from the boron neutron capture reaction based on measured boron concentrations in the blood at the time of BNCT without the need for analysis of tumor samples from individual patients.

Boron

FT-IR microspectroscopic detection of metabolically deuterated compounds in the rat cerebellum: a novel approach for the study of brain metabolism.

Deuteration provides a novel means for studying metabolism in biological organisms and avoids the use of radioisotopes. Ingestion of D2O enriched drinking water causes deuterium to be metabolically incorporated into molecules within tissues. The incorporation of deuterium into various chemical functional groups then can be monitored via infrared spectroscopy. The excellent spatial resolution that can be achieved with Fourier transform infrared (FT-IR) microspectrometers allows collection of infrared spectra from select microscopic regions of tissue specimens. Thus, combining deuteration together with FT-IR microspectroscopy enables analysis of metabolic activities by probing subregions within the microscopic field. In the present study, adult rats were given drinking water containing 30% or 40% D2O for 5 1/2 weeks. Frozen sections were prepared from the cerebellum, and infrared spectra were collected from the molecular layer, granule cell layer and white matter with FT-IR microspectrometers, using both conventional and synchrotron sources. The CD:CH and ND,OD:NH,OH ratios were highest in the molecular layer and lowest in the white matter. The high ratios in the molecular layer are consistent with the active synthesis and recycling at synapses, which are abundant structures in this layer. The low levels in the white matter are consistent with radioactive measures that found slow turnovers of proteins and lipids in myelin, which is the main constituent of white matter. In addition to describing the metabolic incorporation of deuterium, a graphic description of the distribution of chemical functional groups in the various layers of the cerebellum is presented. In summary, this study demonstrates that FT-IR microspectroscopy in conjunction with administration of D2O in drinking water can be used to reveal relative metabolic activities in various layers of the cerebellum. We predict that metabolic activities in other tissues and tissues in different states, e.g., disease states, can be analyzed in a similar manner.

Animals

Boron neutron capture therapy for glioblastoma multiforme using p-boronophenylalanine and epithermal neutrons: trial design and early clinical results.

A Phase I/II clinical trial of boron neutron capture therapy (BNCT) for glioblastoma multiforme is underway using the amino acid analog p-boronophenylalanine (BPA) and the epithermal neutron beam at the Brook-haven Medical Research Reactor. Biodistribution studies were carried out in 18 patients at the time of craniotomy using an i.v. infusion of BPA, solubilized as a fructose complex (BPA-F). There were no toxic effects related to the BPA-F administration at doses of 130, 170, 210, or 250 mg BPA/kg body weight. The tumor/ blood, brain/blood and scalp/blood boron concentration ratios were approximately 3.5:1, 1:1 and 1.5:1, respectively. Ten patients have received BNCT following 2-hr infusions of 250 mg BPA/kg body weight. The average boron concentration in the blood during the irradiation was 13.0 +/- 1.5 micrograms 10B/g. The prescribed maximum dose to normal brain (1 cm3 volume) was 10.5 photon-equivalent Gy (Gy-Eq). Estimated maximum and minimum doses (mean +/- sd, n = 10) to the tumor volume were 52.6 +/- 4.9 Gy-Eq (range: 64.4-47.6) and 25.2 +/- 4.2 Gy-Eq (range: 32.3-20.0), respectively). The estimated minimum dose to the target volume (tumor +2 cm margin) was 12.3 +/- 2.7 Gy-Eq (range: 16.2-7.8). There were no adverse effects on normal brain. The scalp showed mild erythema, followed by epilation in the 8 cm diameter field. Four patients developed recurrent tumor, apparently in the lower dose (deeper) regions of the target volume, at post-BNCT intervals of 7,5,3.5 and 3 months, respectively. The remaining patients have had less than 4 months of post-BNCT follow-up. BNCT, at this starting dose level, appears safe. Plans are underway to begin the dose escalation phase of this protocol.

Adult

Single-and dual-energy CT with monochromatic synchrotron x-rays.

We explored the potential for clinical research of computed tomography (CT) with monochromatic x-rays using the preclinical multiple energy computed tomography (MECT) system at the National Synchrotron Light Source. MECT has a fixed, horizontal fan beam with a subject apparatus rotating about a vertical axis; it will be used for imaging the human head and neck. Two CdWO4-photodiode array detectors with different spatial resolutions were used. A 10.5 cm diameter acrylic phantom was imaged with MECT at 43 keV and with a conventional CT (CCT) at 80 kVp: spatial resolution approximately equal to 6.5 line pairs (lp)/cm for both; slice height, 2.6 mm for MECT against 3.0 mm for CCT; surface dose, 3.1 cGy for MECT against 2.0 cGy for CCT. The resultant image noise was 1.5 HU for MECT against 3 HU for CCT. Computer simulations of the same images with more precisely matched spatial resolution, slice height and dose indicated an image-noise ratio of 1.4:1.0 for CCT against MECT. A 13.5 cm diameter acrylic phantom imaged with MECT at approximately 0.1 keV above the iodine K edge and with CCT showed, for a 240 micrograms I ml-1 solution, an image contrast of 26 HU for MECT and 13 and 9 HU for the 80 and 100 kVp CCT, respectively. The corresponding numbers from computer simulation of the same images were 26, 12, and 9 HU, respectively. MECT's potential for use in clinical research is discussed.

Acrylates

Synthesis of a nickel tetracarboranylphenylporphyrin for boron neutron-capture therapy: biodistribution and toxicity in tumor-bearing mice.

Nickel-2,3,7,8,12,13,17,18-octaacetic acid-5,10,15,20-tetra-[3-carboranyl-methoxyphenyl]-porphyrin octamethylester (NiTCP) was given in a Cremophor EL, a polyethoxylated castor oil, and propylene glycol emulsion to BALB/c mice bearing transplanted s.c. KHJJ mammary carcinomas. A total dose of 244 microg NiTCP/gram body weight (gbw) (54 microg B/gbw) was given in 6 i.p. injections over a 32 hr period. Observations of behavior and changes in body weight and chemical and hematological blood tests indicated little or no toxicity from NiTCP over a period of 6-90 hr after injections. Boron concentrations near tumor margins were 160-180 microg B/g at 41-90 hr after the last injection. Tumor:normal brain boron concentration ratios reached approx. 10:1 and tumor:blood ratios reached approx. 250:1 after 4 days. There was no evidence of thrombocytopenia or other potentially important toxicities. Our findings place NiTCP among the leading candidates for pre-clinical experiments aimed toward improvement upon the compounds being tested for boron neutron-capture therapy of glioblastoma multiforme.

Alanine Transaminase

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and macroscopic breadth (i.e., microplanar). Thirty-six rats were exposed head-on either to an upright 4-mm-high, 20- or 37-microns-wide beam or to a horizontal 7-mm-wide, 42-microns-high beam of mostly 32- to 126-keV, minimally divergent x-rays from the X17 wiggler at the National Synchrotron Light Source at Brookhaven National Laboratory. Parallel slices of the head, separated at either 75 or 200 microns on center, were exposed sequentially at 310-650 grays (Gy) per second until each skin-entrance absorbed dose reached 312, 625, 1250, 2500, 5000, or 10,000 Gy. The rats were euthanized 2 weeks or 1 month later. Two rats with 10,000-Gy-entrance slices developed brain tissue necrosis. All the other 10,000- and 5000-Gy-entrance slices and some of the 2500- and 1250-Gy-entrance slices showed loss of neuronal and astrocytic nuclei and their perikarya. No other kind of brain damage was evident histologically in any rat with entrance absorbed doses < or = 5000 Gy. Brain tissues in and between all the 312- and 625-Gy-entrance slices appeared normal. This unusual resistance to necrosis is central to the rationale of microplanar beam radiation therapy for brain tumors.

Animals

Improved apparatus for neutron capture therapy of rat brain tumors.

PURPOSE: The assembly for irradiating tumors in the rat brain at the thermal neutron beam port of the Brookhaven Medical Research Reactor was redesigned to lower the average whole-body dose from different components of concomitant radiation without changing the thermal neutron fluence at the brain tumor. METHODS AND MATERIALS: At present, the tumor-bearing rat is positioned in a rat holder that functions as a whole-body radiation shield. A 2.54 cm-thick collimator with a centered conical aperture, 6 cm diameter tapering to 2 cm diameter, is used to restrict the size of the thermal neutron field. Using the present holder and collimator as a baseline design, Monte Carlo calculations and mixed-field dosimetry were used to assess new designs. RESULTS: The computations indicate that a 0.5 cm-thick plate, made of 6Li2CO3 dispersed in polyethylene (Li-poly), instead of the existing rat holder, will reduce the whole-body radiation dose. Other computations show that a 10.16 cm-thick (4 inches) Li-poly collimator, having a centered conical aperture of 12 cm diameter tapering to 2 cm diameter, would further reduce the whole-body dose. CONCLUSION: The proposed irradiation apparatus of tumors in the rat brain, although requiring a 2.3-fold longer irradiation time, would reduce the average whole-body dose to less than half of that from the existing irradiation assembly.

Animals

Derivations of relative biological effectiveness for the high-let radiations produced during boron neutron capture irradiations of the 9L rat gliosarcoma in vitro and in vivo.

PURPOSE: Relative biological effectiveness (RBE) values for the high linear-energy-transfer particles produced during boron neutron capture therapy have generally been based on theoretical considerations or in vitro experiments. The purpose of this study was to independently determine RBE values for all of the boron neutron capture therapy dose components. METHODS AND MATERIALS: Clonogenic cell survival data were obtained for 9L rat gliosarcoma cells irradiated in the Brookhaven Medical Research Reactor thermal neutron beam both in vitro and as an intracerebral tumor. These data were analyzed using the linear quadratic model for cell survival to derive measured RBE values for all beam components and for a number of different boron compounds. RESULTS: In the absence of boron, the combined effects of the protons from the nitrogen capture, 14N(n,p)14C, and the fast neutron scatter, 1H(n,n')p, reactions generated RBEs of 3.7 in vitro and 3.2 in an in vivo/in vitro excision assay, compared to 250 kVp X rays using an end point of 1% cell survival. Apparent RBEs for the 10B(n,alpha)7Li reaction products were calculated from cell survival data following reactor irradiations in the presence of the amino acid p-boronophenylalanine, the sulfhydryl dodecaborate monomer or dimer, or boric acid. Apparent RBEs for the 10B(n,alpha)7Li reaction ranged from 1.2 to 9.8 depending on which boron compound was used. RBEs from the in vitro studies were consistently higher than from the in vivo/in vitro studies. Under any conditions, the apparent RBE for the 10B(n,alpha)7Li reaction with p-boronophenylalanine was higher than that with any other boron compound tested. CONCLUSIONS: Generally accepted RBE values for the fast neutron and 14N(n,p)14C reaction components of the total dose are too low. The apparent RBEs calculated for the 10B(n,alpha)7Li reaction were compound-dependent and consistent with differences in the distribution of 10B relative to glioma cell nuclei.

Animals

A commentary on in vivo lead X-ray fluorescence with reference to the 1992 workshop.

One of the main purposes of this Commentary is to respond to some of the issues raised in a Summary by Todd et al. (1993) of the 1992 Workshop sponsored by the National Institute of Environmental Health Sciences on X-Ray Fluorescence (XRF), as it contains apparently undocumented claims for K-Line XRF (KXRF) techniques and understates the efficacy and clinical research results of the L-Line XRF (LXRF) technique (Rosen et al., 1989; Rosen et al., 1991). This Commentary presents a point of view concerning the Workshop that is different in several respects from that published by Todd, Landrigan and Bloch (Todd et al., 1993). As two of the three co-developers of the L-Line XRF (LXRF) technique, we wish to draw the following information to the attention of readers of Neurotoxicology, some of which was published before the Workshop took place and some of which has been published subsequently (Rosen et al., 1993; Rosen and Markowitz, 1993; Markowitz et al., 1993).

Environmental Health

Biodistribution and toxicity of 2,4-divinyl-nido-o-carboranyldeuteroporphyrin IX in mice.

BALB/c mice with transplanted subcutaneous KHJJ mammary carcinomas were given 2,4-divinyl-nido-o-carboranyldeuteroporphyrin IX (VCDP), a prospective boron carrier for boron neutron-capture therapy, to determine the dose schedule that results in maximal boron uptake in tumor. A total dose of 270 +/- 10 micrograms/g body weight given in a 4-day multiple intraperitoneal injection schedule (3/day) resulted in 30-50 micrograms boron/g tumor. After such a dose, thrombocytopenia, granulocytosis and altered liver enzyme levels were measured in the blood. Blood boron clearance was followed for an 18 hr to 6 day post-injection period. Toxic effects of VCDP subsided within 4-6 days after the last injection. In view of the greater than 30 micrograms/g peak accumulation of boron in tumor from VCDP and the subsequent rapid reversal of VCDP toxicity, further studies of VCDP in small mammals relevant to its distribution, toxicity and potential clinical use for neutron-capture therapy of tumors appear warranted.

Animals

Control of intracerebral gliosarcomas in rats by boron neutron capture therapy with p-boronophenylalanine.

Boron neutron capture therapy (BNCT) of transplanted intracerebral GS-9L rat gliosarcomas was effected by irradiation at a nuclear reactor, primarily with thermal neutrons, after two intragastric doses of p-boronophenylalanine (BPA). At the time of BNCT, tumor 10B levels were approximately 40 micrograms 10B/g with tumor:blood and tumor:brain 10B concentration ratios of about 3.3:1 and 3.9:1, respectively. This resulted in calculated doses to tumor that were approximately 2.3-fold greater than those to normal brain parenchyma and brain vascular endothelium within the treatment volume. Approximately 75% of the tumor dose resulted from the 10B(n,alpha)7Li nuclear reaction. The median survival of untreated rats (n = 20) was 20 days after initiation of tumors. Reactor irradiation only (no BPA) increased the median survival to 25 days (n = 25). None of the rats in the untreated or irradiation-only groups survived longer than 34 days after initiation of tumors. Two BNCT dose levels were used: 8.9 Gy (19.3 Gy x relative biological effectiveness, or Gy-eq) and 13.4 Gy (29.0 Gy-eq). The median post-BNCT survivals of BPA-treated rats in the 8.9-Gy (n = 16) and 13.4-Gy (n = 12) groups were 60 and 120 days, respectively, including seven long-term (greater than 12 months) survivors at 8.9 Gy and six long-term (greater than 5 months) survivors at 13.4 Gy. Survival times following BPA-based BNCT (either 8.9 or 13.4 Gy) were significantly longer than those following 250-kVp X-ray doses of 15 Gy (n = 24), 22.5 Gy (n = 32) or 30 Gy (n = 26).

Animals

In vivo boron-11 MRI and MRS using (B24H22S2)4- in the rat.

In vivo boron-11 magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) were performed on a rat that had been infused with a potential boron neutron capture therapy agent, Na4B24H22S2, using methods for detecting nuclei with a short T2 relaxation time. MRI and MRS were also performed on a euthanized rat that had been similarly infused in vivo. Boron-11 spectral intensities decreased in the living rat over a 25-h period. The results demonstrate the capability of MRI and MRS to noninvasively monitor the distribution and excretion of boron agents in vivo.

Animals

A history of boron neutron capture therapy of brain tumours. Postulation of a brain radiation dose tolerance limit.

Boron neutron capture therapy (BNCT) is a form of radiation therapy mediated by the short-range (less than 10 microns) energetic alpha (4He) and lithium-7 (7Li) ionizing particles that result from the prompt disintegration by slow neutrons of the stable (nonradioactive) nucleus boron-10 (10B). Recent advances in radiobiological and toxicological evaluation of tumour-affinitive boron-containing drugs and in optimization of the energies of neutrons in the incident beam have spurred interest in BNCT. This article presents a history of BNCT that emphasizes studies in the USA. A new dosimetric analysis of the 1959-1961 clinical trials of BNCT at Brookhaven National Laboratory is also presented. This analysis yields an acute radiation dose tolerance limit estimate of approximately 10 Gy-Eq to the capillary endothelium of human basal ganglia from BNCT. (Gy-Eq: Gray-equivalent, or relative biological effectiveness of a radiation component multiplied by the physical dose of the component (Gy), summed over the component kinds of radiation.)

Boron

Sequential measurements of bone lead content by L X-ray fluorescence in CaNa2EDTA-treated lead-toxic children.

With the development of L X-ray fluorescence (LXRF) to measure cortical bone lead directly, safely, rapidly, and noninvasively, the present study was undertaken to a) evaluate LXRF as a possible replacement for the CaNa2EDTA test; b) quantify lead in tibial cortical bones of mildly to moderately lead-toxic children before treatment; and c) quantify lead in tibial cortical bones of lead-toxic children sequentially following one to two courses of chelation therapy. The clinical research design was based upon a longitudinal assessment of 59 untreated lead-toxic children. At enrollment, if the blood lead (PbB) was 25 to 55 micrograms/dL and the erythrocyte protoporphyrin (EP) concentration was greater than or equal to 35 micrograms/dL, LXRF measurement of tibial bone lead was carried out. One day later, each child underwent a CaNa2EDTA provocative test. If this test was positive, lead-toxic children were admitted to the hospital for 5 days of CaNa2EDTA therapy. These tests were repeated 6 weeks and 6 months after enrollment. Abatement of lead paint hazards was achieved in most apartments by the time of initial hospital discharge. The LXRF instrument consists of a low energy X-ray generator with a silver anode, a lithium-doped silicon detector, a polarizer of incident photons, and a multichannel X-ray analyzer. Partially polarized photons are directed at the subcutaneous, medial mid-tibial cortical bone. The LXRF spectrum, measured 90 degrees from the incident beam, reveals a peak in the 10.5 KeV region, which represents the lead L alpha line.(ABSTRACT TRUNCATED AT 250 WORDS)

Bone and Bones

Sequential measurements of bone lead content by L X-ray fluorescence in CaNa2EDTA-treated lead-toxic children.

With the development of L X-ray fluorescence (LXRF) to measure cortical bone lead directly, safely, rapidly, and noninvasively, the present study was undertaken to a) evaluate LXRF as a possible replacement for the CaNa2EDTA test; b) quantify lead in tibial cortical bones of mildly to moderately lead-toxic children before treatment; and c) quantify lead in tibial cortical bones of lead-toxic children sequentially following one to two courses of chelation therapy. The clinical research design was based upon a longitudinal assessment of 59 untreated lead-toxic children. At enrollment, if the blood lead (PbB) was 25 to 55 micrograms/dL and the erythrocyte protoporphyrin (EP) concentration was greater than or equal to 35 micrograms/dL, LXRF measurement of tibial bone lead was carried out. One day later, each child underwent a CaNa2EDTA provocative test. If this test was positive, lead-toxic children were admitted to the hospital for 5 days of CaNa2EDTA therapy. These tests were repeated 6 weeks and 6 months after enrollment. Abatement of lead paint hazards was achieved in most apartments by the time of initial hospital discharge. The LXRF instrument consists of a low energy X-ray generator with a silver anode, a lithium-doped silicon detector, a polarizer of incident photons, and a multichannel X-ray analyzer. Partially polarized photons are directed at the subcutaneous, medial mid-tibial cortical bone. The LXRF spectrum, measured 90 degrees from the incident beam, reveals a peak in the 10.5 KeV region, which represents the lead L alpha line.(ABSTRACT TRUNCATED AT 250 WORDS)

Bone and Bones