PubMed Health⌕ Search

Biomedical subjects

D N Vieira

Publications and source records attributed to D N Vieira.

At least 19 recordsLinked to original sources

Determination of parathion in biological fluids by means of direct solid-phase microextraction.

A new and simple procedure for the determination of parathion in human whole blood and urine using direct immersion (DI) solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. This technique was developed using only 100 microL of sample, and ethion was used as internal standard (IS). A 65-microm Carbowax/divinylbenzene (CW/DVB) SPME fibre was selected for sampling, and the main parameters affecting the SPME process such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH effect were optimized to enhance the sensitivity of the method. This optimization was also performed to allow the qualitative determination of parathion's main metabolite, paraoxon, in blood. The limits of detection and quantitation for parathion were 3 and 10 ng/mL for urine and 25 and 50 ng/mL for blood, respectively. For paraoxon, the limit of detection was 50 ng/mL in blood. The method showed linearity between the LOQ and 50 microg/mL for both matrices, with correlation coefficients ranging from 0.9954 to 0.9999. Precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries were 35.1% for urine and 6.7% for blood. Other parameters such as dilution of sample and stability were also validated. Its simplicity and the fact that only 100 microL of sample is required to accomplish the analysis make this method useful in forensic toxicology laboratories to determine this compound in intoxications, and it can be considered an alternative to other methods normally used for the determination of this compound in biological media.

Humans↗

Analytical approach to determine ticlopidine in post-mortem blood.

A new and sensitive method to determine ticlopidine in whole human blood using proadifen as the internal standard (IS) is described. The analyte and IS were extracted by solid-phase extraction using Oasis HLB cartridges, and the extracts were analyzed by gas chromatography-electron impact ionisation-mass spectrometry (GC/EI-MS). Calibration curves were established daily in spiked blood samples using a non-linear calibration model, between 0.01 and 4.5 microg/mL. The correlation coefficients were higher than 0.995. Precision and accuracy fulfilled the internationally accepted criteria (coefficients of variation were less than 9%, and the measured concentrations were within +/-7% of the true value). Limits of detection and quantitation were respectively, 3 and 10 ng/mL. No interfering substances were detected by analysis of 10 blank blood samples of different origin. Mean recovery, calculated at three concentration levels, was 71%. Because of its simplicity and speed, the proposed method can be applied in the determination of this inhibitor of platelet aggregation in whole blood samples, and is suitable for application in toxicology routine analysis.

Chromatography, Gas↗

Determination of quinalphos in blood and urine by direct solid-phase microextraction combined with gas chromatography-mass spectrometry.

A new method based on direct solid-phase microextraction (DI-SPME) followed by gas chromatography-mass spectrometry was developed for the purpose of determining quinalphos in blood and urine. Two types of coated fibre have been assayed and compared: carbowax/divinylbenzene (CW/DVB 65 microm) and polydimethylsiloxane (PDMS 100 microm). The main parameters affecting the SPME process such as temperature, salt addition, pH, stirring and adsorption/desorption time profiles were optimized to enhance the sensitivity of the procedure. The method was developed using only 100 microL of blood and urine. Limits of detection of the method for blood and urine matrices were, respectively, 10 and 2 ng/mL. Linearity was established over concentration ranges from 0.05 to 50 microg/mL for blood, and 0.01 to 50 microg/mL for urine, with regression coefficients ranging between 0.9991 and 0.9999. Intra- and interday precision values were less than 13%, and accuracy was within +/-15% of the nominal concentration for all studied levels in both matrices. Absolute recoveries were 14 and 26% for blood and urine, respectively.

Adsorption↗

Solid-phase microextraction for gas chromatographic/mass spectrometric analysis of dimethoate in human biological samples.

A new, simple and rapid procedure for the determination of dimethoate in urine and blood samples was developed using direct immersion solid-phase microextraction and gas chromatography/mass spectrometry. This technique required only 0.1 mL of sample, and ethion was used as internal standard. Two types of coated fibre were compared (100 microm polydimethylsiloxane, and 65 microm Carbowax/divinylbenzene). Other parameters, such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH, were optimized to enhance the sensitivity of the method. Limits of detection (LODs) and quantitation (LOQs) were 50 and 100 ng/mL for urine and 200 and 500 ng/mL for blood, respectively. The method was found to be linear between the LOQ and 40 microg/mL for urine, and between the LOQ and 50 microg/mL for blood, with correlation coefficients ranging from 0.9923-0.9996. Precision (intra- and interday) and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries of dimethoate were 1.24 and 0.50% for urine and blood, respectively. Because of its simplicity and the fact that small volumes of sample are used, the described method can be successfully used in the diagnosis of poisoning by this pesticide, namely in those situations where the sample volume is limited, as frequently occurs in forensic toxicology.

Dimethoate↗

Population data on 15 autosomal STRs in a sample from East Timor.

Allele frequencies for the fifteen STRs included in the AmpF/STR Identifiler (CSF1PO, D2S1338, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D19S433, D21S11, FGA, TH01, TPO and VWA) were estimated from a sample of 186 unrelated individuals from East Timor. No deviations from Hardy-Weinberg equilibrium were observed (only after applying the Bonferroni correction in the cases of D2S1338, TPO and D5S818). Genetic parameters of forensic interest were calculated and comparison with geographically nearby populations was performed.

DNA Fingerprinting↗

Application of solid phase microextraction to the determination of strychnine in blood.

A simple and rapid method based on solid phase microextraction (SPME) via direct immersion followed by gas chromatography coupled with electron impact ionization/mass spectrometry (GC/EI-MS) was developed for the determination of strychnine in blood. Papaverine was used as internal standard (I.S.). Two types of fibre coating were tested, 100 microm polydimethylsiloxane and 65 microm Carbowax/Divinylbenzene, the latter giving higher recoveries of the compound. The main factors affecting the SPME process, such as sample dilution (1:10), adsorption and desorption times (20 and 10 min, respectively), carry-over effect (not observed), pH and salt addition (no modifications on pH or salt concentration) were optimized. The procedure was validated in terms of linearity (r(2)=0.9992 for concentrations ranging from 0.10 to 5.00 microg/mL), intra and interday precision (0.93 and 4.62%, respectively at 0.50 microg/mL; 3.33 and 8.06%, respectively at 2.50 microg/mL), sensitivity (6.83 and 8.91 ng/mL for LOD and LOQ, respectively) and extraction recovery (0.54 and 0.39% at 0.50 and 2.50 microg/mL, respectively). The developed procedure was found suitable for forensic investigations and was considered a good alternative to the liquid-liquid extraction methods normally used for the determination of this compound in biological media.

Adsorption↗

Vitreous humour as a complementary sample to blood for the detection/confirmation of diazepam: ante-mortem and post-mortem studies in an animal model.

The quantification of medical or toxic substances in vitreous humour (VH) could be very useful in forensic toxicology when blood sample determinations are impossible due to absence or deterioration. However, few studies have been made in this area and even fewer have tried to find a relationship between drug levels in both samples. To determine a correlation ratio between blood and VH diazepam (DZ) levels, we performed an experimental study using rabbits administered with a sub-toxic dose of DZ under known and controlled conditions. Blood and VH samples were collected 0.5, 1, 2, 3 and 6 hours after the drug administration in order to determine DZ and its main active metabolite, desmethyldiazepam (DMD). In addition, we have studied an animal group sacrificed 2 hours after intramuscular (i.m.) drug administration with blood and VH collection 24 hours later, to evaluate the existence of possible post-mortem changes. After DZ administration, a fast absorption phase was observed with a plasma Cmax value 1 hour after, followed by a rapid concentration decrease, with a half-life of 1 hour, indicating that, besides elimination, a fast distribution to other organs and tissues and/or hepatic metabolism occurred. Diazepam Cmax value in VH was achieved between 1 and 2 hours, when plasma concentrations had already decreased to half the value. The plasma/VH DZ ratio calculated at this time was 10. In the post-mortem study, while plasma DZ concentration at 24 hours was smaller, DMD levels were higher than those at the time of death. In the VH, both DZ and DMD concentrations at 24 hours were higher than those obtained at the time of death. That is, in both fluids DZ and DMD concentrations were different from those at the time of death and post-mortem distribution and redistribution phenomena occurred. The combination of ante-mortem and post-mortem studies has allowed the determination of a correlation ratio for DZ in the rabbit of 6 x, comparing the concentrations in VH collected 24 hours after death with the concentrations detected in plasma at the time of death. This study opens new perspectives for the use of VH as a complementary sample to blood for DZ detection and confirmation. The putative relevance of the correlation ratio obtained, for forensic toxicology practice with medical substances, namely benzodiazepines, recommends further studies in humans.

Animals↗

A fatal forensic intoxication with fenarimol: analysis by HPLC/DAD/MSD.

Fenarimol (Rubigan) is a pyrimidine ergosterol biosynthesis inhibitor used as a systemic fungicide. The authors present a fatal fenarimol intoxication case analysed in the Forensic Toxicology Service of the National Institute of Legal Medicine. The results were used to compare two different HPLC techniques, regarding selectivity and sensitivity: an HPLC system with a diode array detector (DAD) and an HPLC system with a DAD and a mass spectrometry detector (MSD) with an electrospray interface. All biological samples were submitted to a solid-phase extraction procedure. The detection and quantification limits of fenarimol, linearity, precision and accuracy were evaluated. The fenarimol concentration levels determined were of 89.0 mg/ml in gastric contents, 1.9 mg/g in liver and 0.4 mg/g in kidney. Blood was not available at autopsy. No published data related to fenarimol self-poisoning were found, so it was not possible to interpret the results obtained by comparison with toxic/lethal levels.

Chromatography, High Pressure Liquid↗

A study on ten short tandem repeat systems: African immigrant and Spanish population data.

This work presents the results obtained from a genetic-population study for the D1S1656 system in the population of Southwest Spain (Huelva, Cádiz and Sevilla), Spaniards of Caucasian origin from North Africa (Ceuta), as well as in the black Central West African and Moroccan immigrant populations in Spain. The results of a study of the autochtonous population of the Canary Islands (n=138), and immigrant Central West African populations in Spain (n=132), obtained for nine short tandem repeat (STR) loci (D3S1358, VWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, D7S820), as well as the amelogenin locus, all contained in Profiler Plus (Perkin-Elmer) PCR amplification kits, are also presented. Except for the FGA and VWA data on immigrant Central West African populations in Spain, no deviations from the Hardy-Weinberg equilibrium were detected.

Africa, Central↗

Analytical method for the determination of strychnine in tissues by gas chromatography/mass spectrometry: two case reports.

This paper describes an analytical method for strychnine determination in biological samples by gas chromatography/mass spectrometry and their application in the investigation of two cases involving strychnine ingestion: A fatal case and a clinical one. The strychnine is isolated from biological samples using a liquid-liquid extraction procedure. The clean-up procedure is performed using an acid solution. Papaverine is used as internal standard in the quantification of strychnine. In the analysed specimens, the limits of quantification were 0.1 microg/ml or 0.1 microg/g. The recovery rate ranged from 75.0% to 98.7% and the coefficients of variation ranged from 4.8% to 10.5%.

Acids↗

Population genetics of nine STR loci in two populations from Brazil.

The Short Tandem Repeats (STRs) D3S1358, HUMvWA31/A, HUMFIBRA/FGA, D8S 1179, D2S11, D18S51, D5S818, D13S317, and D7S820 were studied in two Brazilian populations (from Amazonia and S. Paulo) using the "AmpF1 STR Profiler Plus PCR Amplification Kit." The nine loci showed a combined discrimination power greater than 0.9999999999 and a chance of exclusion of 0.9999.

Brazil↗

Population distribution of six PCR-amplified loci in Madeira Archipelago (Portugal).

Frequency data of the short tandem repeat (STR) loci HUMTH01, HUMVWA31/A, HUMF13A1, HUMFES/FPS, D12S391 and HUMFIBRA/FGA were determined in blood stains obtained from a population of unrelated individuals from the Madeira Archipelago. The observed genotype distribution showed no significant deviation from the Hardy-Weinberg equilibrium and there was no evidence for association of alleles among the six loci. Population data showed a combined discrimination power of 0.9999998 and a chance of exclusion of 0.99597. The frequencies are similar to those of other compared caucasian populations but significant differences were found between the Madeira population and Japanese, Chinese, Greenland Eskimos and Quechua Amerindians. The six loci studied, together proved to be highly discriminating and valuable for forensic cases.

Blood Stains↗

Concealed homicidal strangulation by burning.

Compression of the neck, either with the hands or by a ligature, is not an uncommon method of homicide. Burning of the body to try to conceal the homicide may complicate the situation by making it difficult to interpret the findings. We hereby report two cases of homicidal ligature strangulation with extensive burning of the bodies. In both cases, external findings included the presence of a soft piece of fabric around the neck that, when removed, disclosed a portion of pale, unburned skin that vividly contrasted with surrounding areas. Osteocartilaginous lesions were present in only one case. Carboxyhemoglobin levels in both cases were very low, and the histopathologic examination of distal airways for soot particles was negative.

Aged↗

Population study of HUMTH01, HUMVWA31/A, HUMF13A1, and HUMFES/FPS systems in Azores.

The tetrameric short tandem repeat polymorphisms HUMTH01, HUMVWA31/A, HUMF13A1, and HUMFES/FPS were studied in blood stains obtained from a population of unrelated individuals from the Azores Archipelago (Portugal). Gene frequencies were determined and no deviation from the Hardy-Weinberg equilibrium was found. However, the allelic independence test between loci showed linkage disequilibrium between HUMVWA31/A and HUMFES/FPS. A combined discrimination power and chance of exclusion of, respectively, 0.9999 and 0.9534, reveal the high forensic interest of the four systems. No differences with other caucasoid populations were found, but comparison with some asiatic, eskimo, and amerindian populations showed significant statistical differences.

Amino Acid Sequence↗