PubMed Health⌕ Search

Biomedical subjects

D Nacapricha

Publications and source records attributed to D Nacapricha.

4 recordsLinked to original sources

Simple and selective method for determination of iodide in pharmaceutical products by flow injection analysis using the iodine-starch reaction.

This work exploited the well-known iodine-starch reaction for development of a simple flow-injection (FI) method for determination of iodide in pharmaceutical samples. Iodide in an injected zone was oxidized to iodine. A gas diffusion unit enables selective permeation of iodine through a hydrophobic membrane. Detection was made very selective for elemental iodine by employing formation of the I(3)(-)-starch complex. The detection limit (3 S/ N) of the system was 1 mg I L(-1). For a liquid patent medicine used for asthma treatment we suggested modification of the system. Direct injection of this sample, which contains a particularly high concentration level of iodide (ca. 9000 mg I L(-1)), can be achieved by coupling a dialysis unit to the FI system. This has increased the working range to 6000-10,000 mg I L(-1) without employing complicated nanoliter injection.

Flow Injection Analysis↗

A flow system for the determination of metal speciation in soil by sequential extraction.

A flow extraction system with on-line and off-line flame atomic absorption spectrometric (FAAS) detection was developed to speed up, facilitate, and improve the accuracy of sequential extraction for metal speciation in solid materials. A flow extraction system with off-line detection was more advantageous than the on-line detection. In the proposed system, extraction was performed in a closed extraction chamber where extractants were flowing through sequentially. The extract from each extraction was collected in 4-10 fractions to obtain a total of approximately 180 ml for subsequent FAAS determination. The system is simple, easy to construct and operate. It has less risk of contamination and human error. A widely used three-step sequential extraction scheme was used to evaluate the novel system by analyzing Ca, Fe, Mn, Cu, and Zn in a certified reference material. The extraction time for three-step sequential extraction of soil sample was 4 h. The analytical results for Ca, Fe, Mn, Cu, and Zn of a soil certified reference material using the proposed system were compared with those of the conventional batch extraction.

Environmental Monitoring↗

Continuous and stopped flow injection for catalytic determination of total iodine in urine.

This paper describes the use of flow injection (FI) techniques for the determination of iodine in urine, based on the catalytic effect of iodide in the redox reaction between Ce(IV) and As(III). The proposed procedures minimize errors in the conventional batch method arising from the reading of absorbance at a fixed time after addition of Ce(IV) reagent. Two FI systems, for the continuous and stopped modes of operation were assembled. In the continuous-FI system, a thermostated bath was used to increase the sensitivity. However this is not necessary for the stopped-FI system. The two systems are comparable in terms of sensitivity, sample throughput and detection limit. The continuous-FI and the stopped-FI exhibited detection limits (3 sigma) of 2.3 and 3 micrograms I l-1 respectively. Both systems have equal sample throughputs of 35 samples h-1. Calibration plots for both techniques are linear. The FI procedures provide very short analysis times compared to the batch procedure. Using the linear regression test, there is no significant difference between the results from the four methods, i.e., continuous-FI, stopped-FI, conventional method and ICP-MS. The proposed methods are readily applicable for automation and can be an alternative to the conventional procedure for the survey of the iodine deficiency disorder. A condition for sample digestion is also proposed to reduce the amount of chloric acid required for complete digestion. Kinetic information of the reaction can also be obtained from the stopped flow mode.

Flow Injection Analysis↗

A novel continuous-flow sequential extraction procedure for metal speciation in solids.

A continuous-flow extraction system was developed to speed up, facilitate, and improve the accuracy of the chemical fractionation of metals in solid materials. A three-step sequential extraction scheme was used to evaluate the novel system by analyzing calcium (Ca), iron (Fe), manganese (Mn), copper (Cu), and zinc (Zn) in a soil certified reference material (National Institute of Standards and Technology [NIST] SRM 2710). In the proposed system, extraction occurred in a closed chamber through which extractants were passed sequentially. The extracts were collected in a number of subfractions for subsequent name atomic absorption analysis. Apart from the advantages of simplicity, speed, and less risk of the contamination that flow analysis systems usually possess, the continuous-flow system can improve the accuracy of chemical fractionation of metals by sequential extraction. The system ensures that extraction is performed at designated pH values without any need of adjustment. Variation of sample weight to chamber volume ratios from 1:12 to 1:40 had no effect on the extractability of the metals studied. In the extraction of the acid soluble fraction, concentrations of acetic acid in the range 0.11 to 0.5 mol L(-1) had no significant effect on the amounts of metals extracted, except Fe. Increasing the concentration of hydroxylamine in the reducible fraction step from 0.04 to 0.5 mol L(-1) affected the extraction efficiency for Fe, Mn, and Zn. The extraction profile, rather than a single value of extracted concentration, of each element offers additional information about the kinetics of leaching processes and chemical associations between elements in the solid materials.

Environmental Monitoring↗