3.0 vs 1.5 T MRI in the detection of focal cartilage pathology--ROC analysis in an experimental model.

OBJECTIVE: To use receiver operator characteristics (ROC) analysis for assessing the diagnostic performance of three cartilage-specific MR sequences at 1.5 and 3 T in detecting cartilage lesions created in porcine knees. DESIGN: Eighty-four cartilage lesions were created in 27 porcine knee specimens at the patella, the medial and lateral femoral and the medial and lateral tibial cartilage. MR imaging was performed using a fat saturated spoiled gradient echo (SPGR) sequence (in plane spatial resolution/slice thickness: 0.20 x 0.39 mm2/1.5 mm) and two fat saturated proton density weighted (PDw) sequences (low spatial resolution: 0.31 x 0.47 mm2/3 mm and high spatial resolution: 0.20 x 0.26 mm2/2 mm). The images were independently analyzed by three radiologists concerning the absence or presence of lesions using a five-level confidence scale. Significances of the differences for the individual sequences were calculated based on comparisons of areas under ROC curves (A(Z)). RESULTS: The highest A(Z)-values for all three radiologists were consistently obtained for the SPGR (A(Z) = 0.84) and the high-resolution (hr) PDw (A(Z) = 0.79) sequences at 3T. The corresponding A(Z)-values at 1.5 T were 0.77 and 0.69; the differences between 1.5 and 3 T were statistically significant (P < 0.05). A(Z)-values for the low-resolution PDw sequence were lower: 0.59 at 3 T and 0.55 at 1.5 T and the differences between 1.5 and 3T were not significant. CONCLUSION: With optimized hr MR sequences diagnostic performance in detecting cartilage lesions was improved at 3 T. For a standard, lower spatial resolution PDw sequence no significant differences, however, were found.

Animals↗

Quantification of trabecular bone structure using magnetic resonance imaging at 3 Tesla--calibration studies using microcomputed tomography as a standard of reference.

The purpose of this study is to use high-resolution magnetic resonance (MR) imaging at 3 Tesla (3T) to quantify trabecular bone structure in vitro using femoral head specimens, and to correlate the calculated structure measures with those that were determined using microcomputed tomography (microCT), the standard of reference. Fifteen cylindrical cores were obtained from fresh femoral heads after total hip arthroplasty. MR images were obtained at 3T using a transmit-receive wrist coil. High-resolution coronal images were acquired using a modified three-dimensional (3D) fast-gradient echo sequence. From these data sets two-dimensional (2D) structural parameters analogous to bone histomorphometry were derived by using both mean intercept length (MIL) methods based on the plate model and the more recent model-assumption free 3D distance-transformation (DT) methods. The parameters measured by the 2D plate model-based MIL method and the DT method included apparent (App). BV/TV (bone volume/total volume), App. Tb.Th (trabecular thickness), App. Tb.Sp (trabecular separation), and App. Tb.N (trabecular number). Identical regions of interest were analyzed in the MR images and the microCT data sets, and similar structure measures were derived. The means and standard deviations of the parameters over all slices were calculated and MR-derived measures were correlated with those derived from the microCT data sets using linear regression analyses. Structure measures were overestimated with MRI, for example, the mean App. BV/TV was 0.45 for MRI and 0.20 for microT, and the slope of the graph was 1.45. App. Tb.Th was overestimated by a factor of 1.9, whereas App. Tb.Sp was underestimated; Tb.N showed the smallest effect. Correlations between the individual parameters were excellent (App. BV/TV, r2 = 0.82; App. Tb.Sp, r2 = 0.84; App. Tb.N, r2 = 0.81), except for App.Tb.Th (r2 = 0.67). The results of this study show that trabecular bone structure measures may be obtained using 3T MR imaging. These measures, although higher than the standard of reference, show a highly significant correlation with true structure measures obtained by microCT.

Aged↗

Local 3D scaling properties for the analysis of trabecular bone extracted from high-resolution magnetic resonance imaging of human trabecular bone: comparison with bone mineral density in the prediction of biomechanical strength in vitro.

RATIONALE AND OBJECTIVES: A novel, nonlinear morphologic measure [DeltaP(alpha)] based on local 3D scaling properties was applied to high-resolution magnetic resonance images (HR-MRI) of human trabecular bone to predict biomechanical strength in vitro. METHODS: We extracted DeltaP(alpha) and traditional morphologic parameters (apparent trabecular volume fraction, apparent trabecular separation) from HR-MR images of 32 femoral and 13 spinal bone specimens. Furthermore, bone mineral density (BMD) and maximum compressive strength (MCS) were determined. The morphologic measures were compared with BMD in predicting the biomechanical strength. RESULTS: In the vertebral (femoral) specimens, R2 for MCS versus DeltaP(alpha) was 0.87 (0.61) (P < 0.001). Correlation between BMD and MCS was 0.53 (P = 0.05) (0.79 [P < 0.001]) for the vertebral (femoral) specimens. For the femoral specimens, prediction of MCS could be improved further by combining BMD and morphologic parameters by multiple regression (R2 = 0.88). CONCLUSIONS: Morphologic measures extracted from HR-MRI considering local 3D-scaling properties can be used to predict biomechanical properties of bone in vitro. They are superior to 2-dimensional standard linear morphometric measures and, depending on the anatomic location, more reliably predict bone strength as measured by MCS than does BMD.

Adult↗

Structure analysis of high resolution magnetic resonance imaging of the proximal femur: in vitro correlation with biomechanical strength and BMD.

The purpose of this study was to use high resolution magnetic resonance imaging (HR-MRI) combined with structure analysis to investigate the trabecular structure of the human proximal femur and to compare this technique with bone mineral density (BMD) using dual energy X-ray absorptiometry (DXA) in the prediction of bone strength in vitro. Thirty-one fresh human proximal femur specimens were examined with HR-MRI using a T1-weighted 3D spinecho-sequence in a coronal plane (voxel size: 0.195 x 0.195 x 0.9 mm and 0.195 x 0.195 x 0.3 mm). In these images structure parameters analogous to standard bone histomorphometry were obtained in a femoral head, neck, and trochanteric region of interest (ROI). In addition, BMD measurements were obtained using DXA and finally, all specimens were tested biomechanically in a materials testing machine, and maximum compressive strength (MCS) was determined. Correlations between BMD and MCS were significant (p <0.01) with R-values up to 0.74. Correlating structure parameters and MCS R-values up to 0.69 (P <0.01) were obtained. Using multivariate regression analysis, combining structure parameters and BMD, improved correlations versus MCS substantially (up to R = 0.93; P <0.01). In conclusion, this study showed that in an experimental setting, structure parameters determined in high resolution MR images of the proximal femur correlated significantly with bone strength. The highest correlations, however, were obtained combining BMD and structure measures.

Aged↗

Changes in calcaneal trabecular bone structure assessed with high-resolution MR imaging in patients with kidney transplantation.

The purpose of this study was to use high-resolution magnetic resonance (HR-MR) imaging to analyze the trabecular bone structure of the calcaneus in patients before and after renal transplantation and to compare this technique with bone mineral density (BMD) in predicting therapy-induced bone loss and osteoporotic fracture status. HR-MR imaging (voxel size: 0.195 x 0.195 x 1 mm) was performed at 1.5 T with an axial and sagittal orientation in 48 patients after transplantation, 12 patients before renal transplantation and 20 healthy controls. Structure measures analogous to standard histomorphometry and fractal dimension were determined in these images. BMD measurements of the lumbar spine and the proximal femur were obtained in the healthy female controls and the patients. Vertebral and peripheral fracture status were determined in all patients. The structural measures app.BV/TV, Tb.Sp, Tb.Th and Tb.N showed significant differences between controls and patients (p<0.05) while fractal dimension showed no significant differences. Neither the structural measures nor BMD showed significant differences between patients before and after transplantation. Correlations between time after transplantation versus structural measures and BMD were not significant. Differences between fracture and nonfracture patients were significant for the structural measures app.BV/TV, Tb.Sp and Tb.N (axial images) as well as for app.Tb.Th (sagittal images) and spine BMD (p<0.05) but not for hip BMD. Using odds ratios the strongest discriminators between patients with and without fractures were app. BV/TV, app.Tb.Sp (axial images) and app.Tb.Th (sagittal images), even after adjustment for age and BMD. Using receiver operating characteristic analysis the highest diagnostic performance was found for a combination of BMD and structural measures. In conclusion, our results indicate that structural measures obtained from HR-MR images may be used to characterize fracture incidence in kidney transplant patients; the best results, however, are obtained using a combination of BMD and structural measures.

Adult↗

High-resolution MRI and micro-FE for the evaluation of changes in bone mechanical properties during longitudinal clinical trials: application to calcaneal bone in postmenopausal women after one year of idoxifene treatment.

OBJECTIVE: To investigate whether recently developed in vivo high-resolution magnetic resonance-imaging and micro-finite element techniques can monitor changes in bone mechanical properties during long-term clinical trials aiming at evaluating the efficacy of new drugs for the treatment of osteoporosis. DESIGN: Comparison of baseline and follow-up mechanical parameters calculated using micro-finite element analysis of the calcaneus for subjects participating in a study investigating the effect of idoxifene. BACKGROUND: Contemporary measurements for the evaluation of bone mechanical properties, based on dual-energy X-ray absorptiometry measurements, are not very accurate and require large trial populations. METHODS: A total of 56 postmenopausal subjects received either a placebo, 5 mg or 10 mg per day of idoxifene. Magnetic resonance-images of the calcaneus were made at baseline and after one year. Mechanical parameters of a trabecular volume of interest in the calcaneus were calculated using micro-finite element analysis. RESULTS: Although there were no significant differences between the mean changes in the treated groups and the placebo group, there were significant changes from baseline within groups after one year of treatment. Significant changes, however, were found only for mechanical parameters and only in the treated groups. CONCLUSIONS: The present study is the first demonstration that longitudinal changes in bone mechanical properties due to trabecular micro-architectural changes may be quantified in long-term clinical studies. Since significant changes in mechanical parameters were obtained for the treated groups whereas no significant change in bone mass was found we conclude that the application of these techniques may increase the clinical significance of these trials. RELEVANCE: A precise diagnosis of in vivo bone mechanical properties that accounts for (changes in) trabecular bone architecture is of particular importance for longitudinal clinical trials aiming at evaluating the efficacy of new drugs since it can lead to clinically relevant results from shorter follow-up intervals and may enable a reduction of the number of patients involved in the trial.

Bone Density↗

T2 relaxation time histograms in multiple sclerosis.

An accurate measurement of the transverse relaxation time T(2), and the histogram of T(2) in the brain parenchyma can be accomplished in vivo using a multi-echo magnetic resonance imaging sequence. An estimate of the error in the T(2) measurement is derived using copper sulfate doped water phantoms. Correction factors are calculated and applied to the signal intensity of each voxel prior to the in vivo T(2) evaluation. These corrected T(2) are in good agreement with the theoretical values calculated from copper sulfate concentrations. This technique is then applied to calculate T(2) histograms of the brain. The population studied was composed of normal volunteers and multiple sclerosis patients. The corrected T(2) histogram method discriminates the normal control population from the MS population, and also discriminates between relapsing-remitting patients and primary progressive or secondary progressive patients. Moreover using this approach we are able to detect in MS patients a global shift of the T(2) of the white mater toward higher values. The results of this study showed that the method is easy to implement and may be used to characterize MS pathology.

Brain↗

Does the trabecular bone structure depicted by high-resolution MRI of the calcaneus reflect the true bone structure?

RATIONALE AND OBJECTIVES: The purpose of this study was to compare trabecular bone structure parameters assessed with high-resolution magnetic resonance imaging (HR-MRI) with those determined in specimen sections. METHODS: High-resolution MR images were obtained for 30 calcaneus specimens with a three-dimensional, T1-weighted spin-echo sequence (spatial in-plane resolution 0.195 mm, slice thicknesses of 0.3 and 0.9 mm). Thirty-eight sections were obtained from the specimens, and contact radiography was performed. In the corresponding sections, structural parameters analogous to bone histomorphometry were determined. RESULTS: Significant correlations between MRI-derived structural parameters and those derived from macro pathological sections were found: r values of up to 0.75 were obtained (P < 0.01). The highest correlations were found for apparent bone volume/total volume and trabecular thickness. Image thresholding techniques showed a significant impact on these correlations (P < 0.01). The thinner MR sections were less susceptible to the different thresholding algorithms. CONCLUSIONS: Trabecular bone structure depicted by HR-MR images is significantly correlated with that shown in macro sections (P < 0.01); however, a number of limitations have to be considered, including the substantial impact of thresholding techniques and slice thickness.

Aged↗

Bone-muscle strength indices for the human lower leg.

This cross-sectional study is based on images from the lower leg as assessed by peripheral quantitative computer tomography (pQCT). Measurements were performed in 39 female and 38 male control subjects and 15 female professional volleyball players, all between 18 and 30 years of age. The images were obtained at shank levels of 4%, 14%, 33%, and 66% from the distal end. Bone and muscle cross-sectional areas, and the bones' density-weighted area moment of resistance and of inertia were assessed. From these, muscle-bone strength indices (MBSIs) were developed for compression (CI = 100. bone area/muscle area) and bending (BI = 100. bone area moment of resistance/muscle area/tibia length). Significant correlations between muscle cross-sectional area and bone were found at all section levels investigated. The strongest correlation for compression was observed in the sections at 14% (correlation coefficient r = 0.74), where 4.10 +/- 0.46 cm(2) bone, on average, was related to 100 cm(2) muscle. The compression index (CI) at the 14% level was independent of the tibia length. Interestingly, the 15 athletes had significantly greater CIs than the control subjects. This is most probably due to the greater tension development in the athletes. The highest correlation for bending was for anteroposterior bending at 33% of tibia length (r = 0.81), where the area moment of resistance, R, was on, average, 4.21 +/- 0.54 cm(3)/100 cm(2) muscle/m tibia length. Analysis of the bones' area moment of inertia showed that buckling is a possible cause of bending at the 33% and 66% levels, but not at the 14% level. No gender differences in MBSI were found. Likewise, age was without significant effect. The data show that bone architecture depends critically on muscle cross section and tension development. Moreover, bone geometry (e.g., the tibia length) influences the geometrical distribution of bone mineral, as it was found that long bones adapted to the same compressive strength are wider than short ones. We conclude that MBSIs offer a powerful diagnostic tool for bone disorders and may contribute to improving the treatment of bone metabolic and other diseases.

Absorptiometry, Photon↗

In vivo assessment of trabecular bone structure using fractal analysis of distal radius radiographs.

Our purpose in this study was (i) to measure trabecular bone structure using fractal analysis of distal radius radiographs in subjects with and without osteoporotic hip fractures, and (ii) to compare these measures with bone mineral density (BMD) as well as with measures of trabecular bone structure derived from high resolution magnetic resonance (MR) images. Distal radius radiographs were obtained using semi-industrial films (55 kVp, 400 mAs) in 30 postmenopausal patients, who had suffered osteoporotic hip fractures (74.8+/-8.2 years) in the last 24 months and 27 postmenopausal age-matched (74.6+/-6.6 yr) normal volunteers. Radiographs were digitized at 50 microm. A Fourier power spectrum-based fractal dimension (FD) characterizing the trabecular pattern was measured in a region of interest proximal to the joint line. The fractal dimension was calculated over two spatial frequency (f) ranges: FD1 was calculated over 0.5<log(f)<l.0, FD2 over the higher range 1.0<log(f)<1.5. Trabecular BMD in the radius was obtained using peripheral quantitative computed tomography (pQCT) (Stratec GmbH, Germany). In addition BMD of the proximal femur was determined using dual x-ray absorptiometry (DXA) (QDR 2000, Hologic, MA). In a subset of patients (16 controls and 18 with hip fractures), high resolution MR imaging of the distal radius (spatial resolution of 156 x 156 x 500 microm) was used to obtain measures analogous to bone histomorphometry. There were significant differences (p<0.05) between the fracture and nonfracture groups in the total femur BMD (13%), trabecular BMD in the distal radius (4%), and the fractal dimension in the radiographs (FD2) (3%). The correlations between FD2 and the total femur BMD as well as trabecular bone BMD in the distal radius were -0.48 (p<0.006) and -0.22 (p<0.33); respectively; FD1 increased with BMD and showed lower correlations. FD2 showed good correlations with App. Tb.N (-0.71) and App. Tb.Sp (0.69) (p<0.01), moderate correlation with App BV/TV (-0.53) (p<0.05), and no significant correlation with App. Tb.Th. The correlations between structural measures and FD1 showed the inverse trend and were typically lower. The odds ratios for a hip fracture were 2.44 for total femur BMD, 1.5 for trabecular BMD (radius), and 1.5 for FD2, respectively. In summary, the fractal measures derived from radiographs of the radius show differences between subjects with and without hip fractures, the predictive power of measures in the distal radius are comparable to radial trabecular BMD but lower than that of total hip BMD.

Aged↗

Changes in calcaneal trabecular bone structure after heart transplantation: an MR imaging study.

PURPOSE: To use high-spatial-resolution magnetic resonance (MR) imaging to analyze the trabecular bone structure of the calcaneus in patients before and after heart transplantation and to compare this technique with bone mineral density (BMD) measurement in predicting therapy-induced bone loss and vertebral fracture status. MATERIALS AND METHODS: High-spatial-resolution 1.5-T MR imaging of the calcaneus was performed in 40 men 11-120 months after heart transplantation, in 11 men before heart transplantation, and in 10 age-matched male volunteers. Sagittal and transverse T1-weighted spin-echo images with a voxel size of 0.195 x 0.195 x 1.000 mm were obtained, and structure measurements analogous to bone histomorphometric values were calculated. In addition, the BMD of the lumbar spine was determined in the transplant recipients pre- and postoperatively by using quantitative computed tomography, and vertebral fracture status was assessed. RESULTS: Significant differences in structure and BMD measurements were found between patients before and after heart transplantation (P <. 05). In 17 (42%) of 40 transplant recipients, vertebral fractures were found. Although structure measurements were significantly different between patients with and those without fractures (P <.05), BMDs were not. Correlations between time after transplantation and some structure measurements were moderately significant (P <. 05), but such correlations with BMD measurements were not. CONCLUSION: MR imaging-derived structure measurements in the calcaneus are useful for monitoring bone changes after heart transplantation and assessing vertebral fracture status.

Adult↗

Trabecular bone architecture in the distal radius using magnetic resonance imaging in subjects with fractures of the proximal femur. Magnetic Resonance Science Center and Osteoporosis and Arthritis Research Group.

To determine whether magnetic resonance (MR)-derived measures of trabecular bone architecture in the distal radius are predictive for prevalent hip fractures, 20 subjects with hip fractures and 19 age-matched postmenopausal controls were studied. Bone mineral density (BMD) measures at the hip (dual-energy X-ray absorptiometry, DXA) and the distal radius (peripheral quantitative computed tomography, pQCT) were also obtained. We compared the MR-based structural measures derived in the radius with those in the calcaneus of the same patients. In the radius, images were acquired at an in-plane resolution of 156 microm and a slice thickness of 0.5 mm. Stereologic measures such as the apparent trabecular thickness (app. Tb.Th), fractional trabecular bone volume (app. BV/TV), trabecular spacing (app. Tb.Sp) and trabecular number (app. Tb.N) were derived from the images. Measures of app. Tb.Sp and app. Tb.N in the distal radius showed significant (p<0.05) differences between the two groups, as did hip BMD measures. However, radial trabecular BMD measures showed only a marginal difference (p = 0.05). Receiver operating curve analysis was used to determine the diagnostic efficacy of BMD, structural measures and a combination of the two. The area under the curve (AUC) for total hip BMD was 0.73, and for radial trabecular BMD was 0.69. AUC for most of the measures of trabecular bone structure at the distal radius was lower than for hip BMD measures; however, AUC for app. Tb.N at the radius was 0.69, comparable to trabecular BMD using pQCT. The AUC for combined BMD (hip) and structure measures was higher (0.87) when radius and calcaneus structure was included. Measures of trabecular architecture derived from MR images combined with BMD measures improve the discrimination between subjects with hip fractures and normal age-matched controls.

Aged↗

Ultrasound velocity of trabecular cubes reflects mainly bone density and elasticity.

Studies have indicated that quantitative ultrasound (QUS) variables may be influenced by the mechanical properties of bone which in turn are determined by bone's material and structural properties. However, from these studies it is unclear what role density, elasticity, and structure play in determining velocity. Eighteen defatted, 12-mm cubic trabecular bone specimens were cut from cadaveric specimens. Amplitude-dependent speed of sound (SOS) using a single point QUS system was assessed in three orthogonal axes. Magnetic resonance images were obtained, from which measures of apparent trabeuclar structure were derived. The specimens were nondestructively tested in compression along three orthogonal axes defined by the sides of the cubes. The elastic modulus (in the three directions) and the strength (in one direction) were determined. Trabecular BMD was measured by quantitative computed tomography. SOS varied significantly with direction of measurement, with the highest value in the axial direction (axial:1715 m/s, sagittal: 1662 m/second, and coronal: 1676 m/s). SOS of each of the three axes was generally associated with the various mechanical (r = 0.30-0.87), density (r = 0.81-0.93), and bone structural variables (0.3-0.8). However, after adjusting the SOS correlations by density, only the correlation with elasticity remained significant in the coronal direction. BMD alone explained 88-93% of variance in SOS whereas in the multivariate model, BMD plus elasticity and/or anisotropic variables explained 96-98% of the variance in SOS. Variability of SOS is explained mostly by density and to a small extent by elasticity or anisotropy. Since only 2-6% of the variance of the QUS measurement is not explained by density and elasticity, one could conclude that the remaining variance reflects other properties of bone or perhaps simply measurement error. Evidence that these other properties may be structure related is only found in the anisotropy of QUS parameter.

Adult↗

Fractal analysis of radiographs: assessment of trabecular bone structure and prediction of elastic modulus and strength.

The purpose of this study was to determine whether fractal dimension of radiographs provide measures of trabecular bone structure which correlate with bone mineral density (BMD) and bone biomechanics, and whether these relationships depend on the technique used to calculate the fractal dimension. Eighty seven cubic specimen of human trabecular bone were obtained from the vertebrae and femur. The cubes were radiographed along all three orientations--superior-inferior (SI), medial-lateral (ML), and anterior-posterior (AP), digitized, corrected for background variations, and fractal based techniques were applied to quantify trabecular structure. Three different techniques namely, semivariance, surface area, and power spectral methods were used. The specimens were tested in compression along three orientations and the Young's modulus (YM) was determined. Compressive strength was measured along the SI direction. Quantitative computed tomography was used to measure trabecular BMD. High-resolution magnetic-resonance images were used to obtain three-dimensional measures of trabecular architecture such as the apparent bone volume fraction, trabecular thickness, spacing, and number. The measures of trabecular structure computed in the different directions showed significant differences (p<0.05). The correlation between BMD, YM, strength, and the fractal dimension were direction and technique dependent. The trends of variation of the fractal dimension with BMD and biomechanical properties also depended on the technique and the range of resolutions over which the data was analyzed. The fractal dimension showed varying trends with bone mineral density changes, and these trends also depended on the range of frequencies over which the fractal dimension was measured. For example, using the power spectral method the fractal dimension increased with BMD when computed over a lower range of spatial frequencies and decreased for higher ranges. However, for the surface area technique the fractal dimension increased with increasing BMD. Fractal measures showed better correlation with trabecular spacing and number, compared to trabecular thickness. In a multivariate regression model inclusion of some of the fractal measures in addition to BMD improved the prediction of strength and elastic modulus. Thus, fractal based texture analysis of radiographs are technique dependent, but may be used to quantify trabecular structure and have a potentially valuable impact in the study of osteoporosis.

Biomechanical Phenomena↗

[Computer-assisted structure analysis of trabecular bone in the diagnosis of osteoporosis].

Osteoporosis is characterized by reduced bone mass and a deterioration of bone structure which results in an increased fracture risk. The purpose of this review is to evaluate structure analysis techniques in the diagnosis of osteoporosis. Several imaging techniques were applied to analyze trabecular bone, such as conventional radiography, high-resolution computed tomography (HR-CT) and high-resolution magnetic resonance imaging (HR-MRI). The best results were obtained using high-resolution tomographic techniques. The highest spatial resolutions in vivo were achieved using HR-MRI. These studies show that texture parameters and bone mineral density predict bone strength and osteoporotic fractures in a complementary fashion. Combining both techniques yields the best results in the diagnosis of osteoporosis.

Calcaneus↗

Morphometric texture analysis of spinal trabecular bone structure assessed using orthogonal radiographic projections.

The measurement of bone microstructure as well as bone mineral density may improve the estimation of bone strength. Cubic specimens (N = 26, 12 mm X 12 mm X 12 mm) of human cadaver vertebrae were cut along three orthogonal anatomic orientations, i.e., superior-inferior (SI), medial-lateral (ML), and anterior-posterior (AP). Contact radiographs of the bone cubes along all three orientations were obtained and then digitized by a laser scanner with pixel size of 50 microns x 50 microns. The specimens were tested in compression along the 3 orthogonal orientations and the Young's modulus (YM) was calculated for each direction. Quantitative computed tomography (QCT) was used to obtain a measure of trabecular bone mineral density (BMD). Global gray level thresholding and local thresholding algorithms were used to extract the trabecular bone network. Apparent trabecular bone fraction (ABV/TV), mean intercept length (I.TH), mean intercept separation (I.SP), and number of nodes (N.ND) were measured from the extracted trabecular network. Fractal dimension (Fr.D) of the trabecular bone texture was also measured. Paired t-tests showed that the mean values of each texture parameter (except ABV/TV) and of YM along the SI direction were significantly different (p < 0.05) from those along the ML and AP direction. However, the mean values along the ML and AP directions were not significantly different. Multivariate regression of YM as a function of the texture parameters and BMD showed that without adjusting for the effect of BMD, YM was significantly explained by all the texture parameters (R2 = 0.2-0.6). When BMD was included in the regression, although the variations in YM of ML, AP, and SI orientations could be explained by BMD alone, some of the texture parameters did improve the overall prediction of the biomechanical properties, while, some parameters such as ABV/TV and Fr.D in the ML orientation showed a more significant overall effect in explaining mechanical strength than did BMD. In conclusion, trabecular texture parameters correlated significantly with BMD and YM. Trabecular texture parameters from projectional radiographs reflect the anisotropy of trabecular structure. Quantitative radiographic assessment of trabecular structure using fine-detail radiography can potentially improve the estimation of bone strength.

Adult↗

Proximal femur: assessment for osteoporosis with T2* decay characteristics at MR imaging.

PURPOSE: To use T2* measurements at magnetic resonance (MR) imaging to investigate the trabecular structure of the hip in women with and women without osteoporotic hip fractures and to compare this technique with bone mineral density (BMD) measurements in the diagnosis of fractures. MATERIALS AND METHODS: T2* maps of the proximal femur were obtained at 1.5 T in 23 postmenopausal study patients with osteoporotic hip fractures, 27 age-matched healthy postmenopausal control subjects, and five healthy premenopausal control subjects. A modified gradient-recalled acquisition in the steady state, or GRASS, sequence was used with echo times of 4-40 msec at 4-msec increments. T2* values were measured in five regions of interest: femoral neck, the Ward triangle, trochanter, intertrochanteric region, and total proximal femur. Additionally, BMD measurements of the hip were obtained with dual x-ray absorptiometry. RESULTS: Significant differences between T2* measurements were obtained in all three groups (P < .05). BMD measurements of the hip also showed significant differences (P < .05). For T2* and BMD measurements, odds ratios and areas under the curve in receiver operating characteristic analysis were comparable. Correlations between 1/T2* values and BMD were significant (P < .05). T2* measurements in the proximal femur showed regional variations. CONCLUSION: MR imaging decay characteristics of bone marrow could be used to differentiate between postmenopausal women with and those without osteoporotic hip fractures.

Absorptiometry, Photon↗

A comparative study of trabecular bone properties in the spine and femur using high resolution MRI and CT.

The purpose of this study was to use high resolution (HR) magnetic resonance (MR) and computed tomography (CT) images combined with texture analysis to investigate the trabecular structure of human vertebral and femoral specimens and to compare these techniques with bone mineral density (BMD) in the prediction of bone strength. Twenty-nine bone cubes were harvested from 12 proximal femur cadaver specimens and 29 from 8 spines. HR MR and CT images were obtained, and texture analysis techniques were used to assess trabecular structure. Additionally, BMD, elastic modulus (EM), and maximum compressive strength were determined. R2 for EM versus texture measures computed in the MR images was higher (R2 = 0.27-0.64, p < 0.01) in the spine than in the femur specimens (R2 = 0.12-0.22, p < 0.05). R2 values were similar in the CT images. R2 for EM versus BMD was 0.66 (p < 0.01) in the spine and 0.61 (p < 0.01) in the femur specimens. In the MR images, texture measures combined with BMD in a multivariate-regression model significantly increased R2, while improvement was less significant in the CT images. Thus, texture analysis may provide additional information needed to analyze bone strength and quality.

Adult↗