PubMed Health⌕ Search

Biomedical subjects

D Nozaki

Publications and source records attributed to D Nozaki.

11 recordsLinked to original sources

Stretch reflex excitability of the anti-gravity ankle extensor muscle in elderly humans.

AIM: To examine whether the stretch reflex excitability of the soleus muscle changes with age, stretch reflexes at rest (REST) and during weak voluntary contractions (ACT) were elicited in 18 older and 14 younger subjects. METHOD: The amplitude of the stretch reflex responses and gain, defined as the gradient of the regression line for the relation between stretch reflex responses against the angular velocity of the applied perturbation, were evaluated in each short-latency (M1) and two long-latency components (M2 and M3). RESULTS: It was found that in the older group, both the amplitude and gain of the M1 component did not change from the REST to the ACT conditions, whereas in the younger group both variables significantly increased from the REST to ACT conditions. The latency of the M1 component was significantly shorter under the REST condition (older vs. younger: 51.8 +/- 7.37 vs. 55.1 +/- 8.69 ms), while no group differences were found in those variables under the ACT condition, suggesting that the muscle-tendon complexes of SOL muscles of the older subjects were less elastic and had less slack, probably due to age-related histochemical alterations. Further, the Hoffman reflex (H-reflex), elicited during the REST condition in 10 older and 11 younger subjects showed no significant differences, suggesting that the soleus motoneuron response to the Ia input was comparable between the two subject groups. CONCLUSION: The histochemical alterations occurring with the ageing process might augment the short-latency stretch reflex in the SOL muscle without enhancement of motoneuronal excitability, and this effect might be masked when the muscle is voluntarily activated.

Adult↗

Somatosensory graviception inhibits the soleus H-reflexin standing man - an underwater experiment-.

H-reflexes were elicited in the soleus muscle in subjects standing on a force platform in a water tank, under different loading conditions at the ankle joint. The joint loading was altered by changing the combination of buoys and weights attached to lower limb segments, while the total body mass was kept the same. The results revealed that as the joint load was reduced the H-reflex was significantly enhanced as compared to that under the control condition, while it decreased as the joint load was increased, despite the same background EMG activity level. It was demonstrated that the augmented load information from the lower limb joints has an inhibitory effect on the soleus H-reflex, suggesting that this might be one of underlying neural mechanisms responsible for the suppression of H-reflex during human upright standing.

Comparative Study↗

Reciprocal angular acceleration of the ankle and hip joints during quiet standing in humans.

Human quiet standing is often modeled as a single inverted pendulum rotating around the ankle joint, under the assumption that movement around the hip joint is quite small. However, several recent studies have shown that movement around the hip joint can play a significant role in the efficient maintenance of the center of body mass (COM) above the support area. The aim of this study was to investigate how coordination between the hip and ankle joints is controlled during human quiet standing. Subjects stood quietly for 30 s with their eyes either opened (EO) or closed (EC), and we measured subtle angular displacements around the ankle (thetaa) and hip (thetah) joints using three highly sensitive CCD laser displacement sensors. Reliable data were obtained for both angular displacement and angular velocity (the first derivative of the angular displacement). Further, measurement error was not predominant, even among the angular acceleration data, which were obtained by taking the second derivative of the angular displacement. The angular displacement, velocity, and acceleration of the hip were found to be significantly greater (P<0.001) than those of the ankle, confirming that hip-joint motion cannot be ignored, even during quiet standing. We also found that a consistent reciprocal relationship exists between the angular accelerations of the hip and ankle joints, namely positive or negative angular acceleration of ankle joint is compensated for by oppositely directed angular acceleration of the hip joint. Principal component analysis revealed that this relationship can be expressed as: thetah=gammathetaa with gamma=-3.15+/-1.24 and gamma=-3.12+/-1.46 (mean +/-SD) for EO and EC, respectively, where theta is the angular acceleration. There was no significant difference in the values of y for EO and EC, and these values were in agreement with the theoretical value calculated assuming the acceleration of COM was zero. On the other hand, such a consistent relationship was never observed for angular displacement itself. These results suggest that the angular motions around the hip and ankle joints are not to keep the COM at a constant position, but rather to minimize acceleration of the COM.

Acceleration↗

Functional stochastic resonance in the human brain: noise induced sensitization of baroreflex system.

We demonstrate experimentally that noise can enhance the homeostatic function in the human blood pressure regulatory system. The results show that the compensatory heart rate response to the weak periodic signal introduced at the venous blood pressure receptor is optimized by adding noise to the arterial blood pressure receptor. We conclude that this functional stochastic resonance most likely results from the interaction of noise with signal in the brain stem, where the neuronal inputs from these two different receptors first join together.

Adult↗

Mechanism of stochastic resonance enhancement in neuronal models driven by 1/f noise.

Noise can assist neurons in the detection of weak signals via a mechanism known as stochastic resonance (SR). In a previous study [Phys. Lett. A 243, 281 (1998)], we showed that when colored noise with 1/f(beta) spectrum is added to the FitzHugh-Nagumo (FHN) neuronal model, the optimal noise variance for SR could be minimized with beta approximately 1. In this study, we investigate analytically how the noise color (beta) affects the SR profile in a linearized version of the FHN model. We demonstrate that the aforementioned effect of 1/f noise is related to the dynamical characteristics of the model neuron, i.e., the refractory period, the low-pass filtering effect of the membrane capacitance, and the high-pass filtering effect of the recovery variable.

Animals↗

Gravity-dependent modulation of Ia afferent in human.

Recent work has shown that the H-reflex excitability of the human soleus motoneurones is modulated in reduced gravity and accompanied by a corresponding change in electromyographic (EMG) activity during space flight mission or different gravitational load. Spinal reflexes are often viewed as stereotyped motor patterns with limited scope for modification. However, recent evidence suggests that even short-latency, largely monosynaptic reflexes show a high degree of modulation during simple human motor activities such as walking and standing, and that the pattern of modulation can be specifically altered for the different functional requirements of each activity. Capady and Stein have demonstrated that H-reflex amplitude of the soleus increases progressively during the stance phase and reaches its peak amplitude late in the stance phase during walking. However, during running, the H-reflex is found to be significantly smaller than during walking, suggestion a modified spinal reflex gain for the different functional requirements of the motor behaviors. It is well documented that gravitational loads on the human body, spinal cords are much higher during standing in the water than standing in land. Little is known about the occurrence and influence of neural modulation in spinal cord during different gravitational load, which was not induced by posture but by voluntary background activity. The purpose of the present study was consequently to investigate how to effect is controlled H-reflex modulated during reduced gravity standing in a water in normal subjects.

Adult↗

Supraspinal effects on the fractal correlation in human H-reflex.

In our previous study, 1/f beta-type power spectrum with the spectral exponent beta significantly greater than zero was found in the variability of soleus H-reflex amplitudes. This result indicated that the H-reflex variability was time-correlated owing to fractal characteristics. Furthermore, it was also suggested that the fractal characteristics were generated at the spinal level. The purpose of the present study was to investigate whether the fractal nature of the H-reflex variability was influenced by the loss of supraspinal input. Six healthy normal subjects and seven patients with spinal cord injury participated in this study. Soleus H-reflexes were evoked every 1 s from both legs simultaneously (stimulation intensity: motor threshold) and 1050 successive amplitudes of the H-reflex were recorded. The H-reflex sequence evoked from each leg was analyzed by "coarse graining spectral analysis" to calculate the spectral exponent beta. The value of beta was used to evaluate the level of time-correlation (fractal correlation). Cross-spectral analysis was used to evaluate the degree of synchronization between the H-reflex sequences evoked from both legs. The beta values for normal subjects (0.84 +/- 0.33, left leg; 0.88 +/- 0.34. right leg) were significantly greater (P < 0.001) than those for patients (0.31 +/- 0.18, left leg; 0.32 +/- 0.14, right leg), suggesting that the H-reflex sequences for normal subjects were more time-correlated than for patients. In the frequency range less than 0.2 Hz, the coherence of both legs was high (0.41 +/- 0.14) for normal subjects as compared to 0.20 +/- 0.12 for patients (P < 0.005). In this frequency range, the phase was almost 0 rad for normal subjects, indicating that the H-reflex variabilities of both legs were synchronized. These results suggested that (1) the strong fractal correlation observed in the H-reflex sequences for normal subjects was associated with supraspinal input, and (2) such supraspinal input had equal influence on the reflex arcs of the soleus of both legs.

Adult↗

Fractal correlation in human H-reflex.

The amplitude of the H-reflex has been known to have considerable variability even if the intensity of the stimulation is held constant. However, previous studies largely ignored the time-dependent profile of this variability. Recent mathematical analyses have shown that some seemingly irregular biological signals have fractal properties. A fractal time series is characterized by the property of self-similarity (self-affinity), and has long-range time correlation. The aim of this study was to investigate the question of whether the fluctuation of H-reflex was fractal with strong time-correlation. Soleus H-reflexes were evoked in five healthy subjects at two levels of stimulation intensity [1.2 MT (motor threshold) and 0.9 MT] every 1 s and 1050 successive amplitudes of H-wave and M-wave were recorded twice. The sequences of the H-wave and the M-wave amplitudes were analyzed by "coarse graining spectral analysis" to calculate the percentage of random fractal components in the sequences (%Fractal) and the spectral exponent beta. The %Fractal values of both sequences were above 90% [H-wave: 93.3 +/- 2.3% (1.2 MT), 91.6 +/- 3.1% (0.9 MT); M-wave: 94.3 +/- 3.3%; mean +/- SD]. Nonflat power spectra of the fractal components were observed for the H-wave sequences regardless of the stimulation intensity [beta = 0.75 +/- 0.26 (1.2 MT), 0.80 +/- 0.39 (0.9 MT)], indicating that the sequences were strongly time correlated. On the other hand, the M-wave sequences had a flatter spectrum (beta = 0.26 +/- 0.14) which was close to uncorrelated white noise. These results indicated that: (1) the fractal correlation found in the H-wave sequences was caused neither by the conduction through nerve fibers nor by the transmission at the neuromuscular junction, because the M-wave sequence had a significantly weaker time correlation, and (2) antidromic impulses in a motor nerve induced by the stimulation made a minor contribution to the generation of fractal correlation in the H-wave sequences, because it was preserved when the stimulation intensity was below MT. It was suggested that the fractal correlation in human H-reflex was generated at the synaptic connections to alpha-motoneurons in the spinal cord.

Adult↗

Specific tension of elbow flexor and extensor muscles based on magnetic resonance imaging.

Series cross-section images of the upper extremity were obtained for four men by magnetic resonance imaging (MRI) and anatomical cross-sectional areas (ACSA) of elbow flexor muscles [biceps brachii (BIC), brachialis (BRA), brachioradialis (BRD)] and extensor muscles [triceps brachii (TRI)] were measured. Physiological cross-sectional area (PCSA) was calculated from the muscle volume and muscle fibre length, the former from the series ACSA and the latter from the muscle length multiplied by previously reported fibre/muscle length ratios. Elbow flexion/extension torque was measured using an isokinetic dynamometer and the force at the tendons was calculated from the torque and moment arms of muscles measured by MRI. Maximal ACSA of TRI was comparable to that of total flexors, while PCSA of TRI was greater by 1.9 times. Within flexors, BRA had the greatest contribution to torque (47%), followed by BIC (34%) and BRD (19%). Specific tension related to the estimated velocity of muscle fibres were similar for elbow flexors and extensors, suggesting that the capacity of tension development is analogous between two muscle groups.

Adult↗

Reliability of measurement of oxygen uptake by a portable telemetric system.

The purpose of the present study was to check the reliability of measurements of oxygen uptake (VO2) using a newly developed portable telemetry system. This system (K2) consisted of a face mask, a flow meter, a gas analyser with a transmitter, and a receiver. The total mass for the subject to carry was about 850 g. Three experiments were carried out, firstly to check the reliability and reproducibility of the flow meter and the K2 gas analyser, secondly to check the accuracy of K2 by comparing it with the Douglas bag method (DB), and thirdly to apply K2 to sports activities. In the first experiment, the flow meter was highly accurate up to 180 l.min-1 with good reproducibility. The measurement error of the gas analyser was less than 2%. In the second experiment, there was no significant difference in the calculated ventilation between K2 and DB. The VO2 showed no significant difference between K2 and DB with some exceptions. In the third experiment, we succeeded in the measurement of VO2 during rowing on water. The measurement of VO2 during running and playing soccer was also possible. It would seem that the present system could well be a powerful tool in the field measurement of VO2 during various sports activities.

Exercise↗