High dose oral amiodarone loading: electrophysiologic effects and clinical tolerance.

Although amiodarone is an effective drug for the treatment of life-threatening ventricular arrhythmias, no standard oral loading dose protocol has been defined, and patients often undergo prolonged hospitalization for amiodarone loading. High dose (greater than 1,800 mg/day) oral loading has usually been reserved for unstable patients with incessant ventricular tachyarrhythmias. The current study was designed to 1) examine the clinical and electrophysiologic effects of a high dose oral amiodarone loading regimen in more stable patients; and 2) ascertain its safety and tolerance, possibly allowing shortened amiodarone loading periods and potentially decreased length of hospital stay. The study group included 16 patients with a history of recurrent ventricular arrhythmias and decreased left ventricular function, who were refractory to prior antiarrhythmic drug therapy. The oral loading protocol was 50 mg/kg per day of amiodarone for 3 days, then 30 mg/kg per day for 2 days, followed by maintenance therapy of 300 to 400 mg twice daily. Electrophysiologic testing was performed at baseline, on days 1 and 5 and during week 6. Amiodarone and desethylamiodarone levels were measured and symptoms monitored. Clinically, the high dose loading protocol was well tolerated in 15 of the 16 patients. Arrhythmias were rendered noninducible by day 1 in three patients and remained noninducible throughout the study period in two of the three. The remaining patients continued to have inducible ventricular tachycardia. Ventricular tachycardia cycle length and right ventricular effective refractory period both progressively increased significantly over baseline, starting on day 1. The 15 patients who remained in the study had no significant side effects during the loading period.(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Oral

Spontaneous endless loop tachycardia.

Pacemaker-mediated endless loop tachycardia is usually caused by a P wave displaced from the physiologic position preceding a QRS complex to a time of atrial channel sensitivity after the QRS. Five cases are described of endless loop tachycardia starting after a normally-timed P wave, either spontaneous and preceding a ventricular stimulus or a P wave produced by an atrial channel stimulus followed by a ventricular stimulus and QRS complex. In each instance, the atrial refractory interval (ARI) was shorter than the retrograde conduction time. In four of the cases, prolongation of the atrial refractory interval after the ventricular event ended the tachycardias. In the fifth, in which the pulse generator could not be so programmed, the ventricular inhibited mode was required.

Adult

Wide QRS tachycardia due to AV nodal reentry and a "bystander" bypass tract with slow conduction properties.

An unusual mechanism for recurrent, wide QRS complex supraventricular tachycardia is described in this report. A 25-year-old man with normal PR and QRS intervals during sinus rhythm was shown to have preexcitation with a left bundle branch block pattern during tachycardia and during atrial pacing. Electrophysiologic studies demonstrated slow and decremental conduction properties in an accessory "bystander" AV pathway utilized for antegrade conduction during AV nodal reciprocating tachycardia. The differential diagnosis of this tachycardia is discussed in detail.

Adult

Closed chest catheter ablation of an accessory pathway in a patient with permanent junctional reciprocating tachycardia.

This report describes a 23 year old woman with a lifelong history of permanent junctional reciprocating tachycardia refractory to conventional antiarrhythmic medications who was successfully treated with closed chest, transvenous selective ablation of a posteroseptal bypass tract. Two 100 J (stored) direct-current shocks were delivered to the region of the os of the coronary sinus using a quadripolar catheter positioned in the coronary sinus. At a 2 month follow-up interval, the patient is asymptomatic without recurrence of the tachycardia. It is concluded that in patients with permanent junctional reciprocating tachycardia, selective catheter ablation of a posteroseptal accessory pathway is a feasible alternative to a difficult pharmacologic regimen or to ablative surgery.