Simulation of Doppler ultrasound signals for a laminar, pulsatile, nonuniform flow.

A simulation for Doppler ultrasound quadrature signals from pulsatile, nonuniform flow is presented. It is an extension of an earlier simulation presented by Jones and Giddens (1990a) which was valid for laminar, uniform, steady flow and which included the stochastic characteristics introduced by scattering particles which enter and leave the sample volume at random times. Fourier transform and autoregressive spectral analysis techniques are used to compare the simulated signals to Doppler signals collected from an in vitro flow setup. Power spectra, Doppler frequency estimates and standard deviations of these estimates serve as standards of comparison. Results show that the simulation model generates realistic quadrature signals. The study improves the understanding of the physics of the Doppler process and shows that it can be modeled for complex flow conditions. The input parameters of the simulation are the Doppler instrument parameters and flow characteristics. This allows the simulation to be used for transducer design as well as in the study of the applicability of signal analysis techniques to Doppler ultrasound.

Blood Flow Velocity

Anastomotic intimal hyperplasia: mechanical injury or flow induced.

All anastomotic intimal thickening may not be the same, and the underlying mechanism(s) regulating the different types may vary. We investigated the localization of experimental anastomotic intimal thickening in relation to known biomechanical and hemodynamic factors. Bilateral iliofemoral saphenous vein and polytetrafluoroethylene grafts were implanted in 13 mongrel dogs. The distal end-to-side anastomotic geometry was standardized, and the flow parameters were measured. After 8 weeks, seven of 10 animals (group I) with patent grafts were killed and the anastomoses fixed by perfusion. Histologic sections from each anastomosis were studied with light microscopy, and regions of intimal thickening were identified and quantitated with use of oculomicrometry. To characterize the anastomotic flow patterns, transparent silicone models were constructed from castings of the distal anastomosis of three animals (group II), and flow was visualized with use of helium-neon laser-illuminated particles under conditions simulating the in vivo pulsatile flow parameters. Histologic sections revealed two separate and distinct regions of anastomotic intimal thickening. The first, suture line intimal thickening, was greater in polytetrafluoroethylene anastomoses (0.35 +/- 0.23 microns) than in vein anastomoses (0.15 +/- 0.03 microns, p less than 0.05). The second distinct type of intimal thickening developed on the arterial floor and was the same in polytetrafluoroethylene (0.11 +/- 0.11 microns) and vein anastomoses (0.12 +/- 0.03 microns). Model flow visualization studies revealed a flow stagnation point along the arterial floor resulting in a region of low and oscillating shear where the second type of intimal thickening developed. High shear and short particle residence time were observed along the hood of the graft, an area devoid of intimal thickening.(ABSTRACT TRUNCATED AT 250 WORDS)

Anastomosis, Surgical

Micro-architecture and composition of artery walls: relationship to location, diameter and the distribution of mechanical stress.

PURPOSE: We reviewed the structural basis of the mechanical properties of the arterial wall, in order to establish a coherent micro-anatomical basis for the differences in compliance among different arteries and a framework for assessing changes in the mechanical properties of specific individual arteries in relation to changing physical stresses. DATA IDENTIFICATION: The data and concepts presented here were derived from both earlier and ongoing work. Features that assure stability and integrity in relation to blood flow (wall shear stress) and pressure (mural tensile stress) were examined. Particular attention was paid to the morphogenetic and biosynthetic means by which arteries adapt to normal or abnormal modifications of these forces, particularly in relation to growth, location in the arterial tree and geometric configuration. RESULTS AND CONCLUSIONS: Thickness, composition and architecture of the artery wall, including thickness and composition of the intima, are normally determined by the stresses imposed by pressure and flow. Vessel radius is closely associated with flow, so that a normal baseline level of mean shear stress of about 15 dyn/cm2 is maintained or restored. Wall thickness and composition are determined by wall tension in relation to pressure and radius. Baseline levels of tensile stress differ with location but appear to be similar for homologous vessels. Changes in flow that modify the radius also modify wall tension. Changes in wall thickness and composition are likely to cause changes in compliance, due to altered flow and/or pressure patterns; these changes in compliance may be adaptive rather than destructive. Changes in the compliance of specific arteries over time may be used to evaluate the progression and severity of the conditions underlying these changes.

Animals

Modern spectral analysis techniques for blood flow velocity and spectral measurements with pulsed Doppler ultrasound.

Four spectral analysis techniques were applied to pulsed Doppler ultrasonic quadrature signals to compare the relative merits of each technique for estimation of flow velocity and Doppler spectra. The four techniques were 1) the fast Fourier transform method, 2) the maximum likelihood method, 3) the Burg autoregressive algorithm, and 4) the modified covariance approach to autoregressive modeling. Both simulated signals and signals obtained from an in vitro flow system were studied. Optimal parameter values (e.g., model orders) were determined for each method, and the effects of signal-to-noise ratio and signal bandwidth were investigated. The modern spectral analysis techniques were shown to be superior to Fourier techniques in most circumstances, provided the model order was chosen appropriately. Robustness considerations tended to recommend the maximum likelihood method for both velocity and spectral estimation. Despite the restrictions of steady laminar flow, the results provide important basic information concerning the applicability of modern spectral analysis techniques to Doppler ultrasonic evaluation of arterial disease.

Algorithms

Fluid dynamics in cerebral angiography.

Flow field characteristics are described so that the physician may have a better understanding of the mechanical effects of rapid intravascular injection of a highly ionized hypertonic solution. Theoretical and experimental results which illustrate the fluid dynamics involved are presented. This knowledge may be helpful in diminishing the overall complication rate in cerebral angiography and in outlining the carotid arterial complex, which is frequently the site of dense atheromatous plaque deposition.

Arteries

Measurements of disordered flows distal to subtotal vascular stenoses in the thoracic aortas of dogs.

Instantaneous blood velocity measurements employing a constant temperature hot film anemometer were obtained in the region distal to externally enforced, subtotal vascular stenoses in the descending thoracic aortas of anesthetized dogs. Our objectives were to determine alterations in velocity waveforms and energy spectra as the degree of stenosis was increased. We paid particular attention to distinguishing features of the flow which were characteristic of turbulence. Our results indicate that, for the vessels studied, disturbances in the velocity waveforms occur for very minor localized constrictions. The energy spectra follow certain similarity parameters within a restricted region of the distal velocity field. For severe stenoses relatively high levels of energy exist in frequency ranges which previously have been found to produce poststenotic dilation. The measurements suggest that velocity waveforms and energy spectra provide a very early clue to the existence of localized occlusive vascular disease in larger vessels and that, within a limited region distal to a stenosis, the degree of constriction may be estimated by similarity analysis of the energy spectra.

Animals