Capillary array scanner for time-resolved detection and identification of fluorescently labelled DNA fragments.

The first capillary array scanner for time-resolved fluorescence detection in parallel capillary electrophoresis based on semiconductor technology is described. The system consists essentially of a confocal fluorescence microscope and a x,y-microscope scanning stage. Fluorescence of the labelled probe molecules was excited using a short-pulse diode laser emitting at 640 nm with a repetition rate of 50 MHz. Using a single filter system the fluorescence decays of different labels were detected by an avalanche photodiode in combination with a PC plug-in card for time-correlated single-photon counting (TCSPC). The time-resolved fluorescence signals were analyzed and identified by a maximum likelihood estimator (MLE). The x,y-microscope scanning stage allows for discontinuous, bidirectional scanning of up to 16 capillaries in an array, resulting in longer fluorescence collection times per capillary compared to scanners working in a continuous mode. Synchronization of the alignment and measurement process were developed to allow for data acquisition without overhead. Detection limits in the subzeptomol range for different dye molecules separated in parallel capillaries have been achieved. In addition, we report on parallel time-resolved detection and separation of more than 400 bases of single base extension DNA fragments in capillary array electrophoresis. Using only semiconductor technology the presented technique represents a low-cost alternative for high throughput DNA sequencing in parallel capillaries.

DNA↗

Multiplex dye DNA sequencing in capillary gel electrophoresis by diode laser-based time-resolved fluorescence detection.

A new one-lane, four-dye DNA sequencing method was developed which is based on time-resolved detection and identification of fluorescently labeled primers. For fluorescent labels, we used two newly synthesized rhodamine derivatives (MR200-1, JA169), a new oxazine derivative (JA242), and a commercially available cyanine dye (CY5). The dye fluorescence was excited by a pulsed diode laser emitting at 630 nm. The fluorescence decay was detected by an avalanche photodiode using a single-filter system. The dyes used here, so-called multiplex dyes, can be distinguished and identified via their fluorescence decay patterns. The DNA fragments were labeled at the primer using linkers of various lengths and positions. For separation of the enzymatically generated DNA fragments, capillary gel electrophoresis (CGE) with a 5% linear polyacrylamide gel was employed. On covalent attachment to oligonucleotides, the dyes exhibit fluorescence decay times of 3.7 (MR200-1), 2.9 (JA169), 2.4 (JA242), and 1.6 ns (CY5) measured during CGE. The CGE mobility of the labeled DNA fragments could be controlled and nearly equalized by the coupling position and the linker length. First, time-resolved, one-lane, four-dye DNA sequencing runs in CGE are presented. The sequence information of 660 bp was determined with a probability of correct classification of > 90%. This result was obtained directly from the raw data without any of the mobility corrections that are necessary with other methods.

DNA↗