PubMed Health⌕ Search

Biomedical subjects

D P Lehane

Publications and source records attributed to D P Lehane.

13 recordsLinked to original sources

Enzyme immunoassay for serum lidocaine in antiarrhythmic therapy.

We have adapted the commercially available EMIT kit [Clin. Chem. 23, 1161 (1977)] to the Gilford System 3500 Analyzer. Sample volume is 10 microliter. We compare reagent blank-corrected absorbance changes at 340 nm between 15 and 55 s for samples and a series of calibrators, and calculate results with use of a logarithmic transformation. Within-run precision (CV) for a serum pool with 4.0 mg of added lidocaine per liter was 2.7% (n = 45); day-to-day precision was 3.3% (n = 15). Analytical recoveries of 2 to 6 mg of lidocaine per liter were 90-102% (average, 97.3%). Results correlated significantly with those by a gas-chromatographic technique. No clinically significant interferences by concomitantly administered medications were observed. The procedure is rapid (42 samples per hour) and is well suited to the fast response required in monitoring lidocaine therapy. Usefulness of the assay data in the management of arrhythmias in the coronary care unit is discussed.

Autoanalysis↗

Amylase activity in serum and urine: comparison of results by the amyloclastic, dyed-starch, and nephelometric techniques.

We assayed serum and urine specimens for amylase activity by the nephelometric (I),dyed-starch (Amylochrome) (II), and mayloclastic (III) techniques. For serum, the correlation coefficients of the regression lines were: I vs. II, 0.978 (n = 106); I vs. III, 0.736 (n = 110); and II vs. III, 0.739 (n = 108). For urine, they were I vs. II, 0.938 (n = 49); and I vs. III, 0.752 (n = 46). Because calculation of the Kolmogorov-Smirnov statistic showed the distributions to be nongaussian, Spearman rank correlation coefficients were determined and showed that I and II correlated well but neither method correlated with III. The clinical data show that I and II gave above-normal activities in every case of pancreatitis, but III gave normal values in two of eight cases. In all cases, I and II were more sensitive, giving higher amylase activities (as compared with the upper limit of normal) than did III. The nephelometric procedure is most suitable for routine and emergency testing; the dyed-starch assay is equally sensitive and reliable, but less convenient. The amyloclastic procedure appears to be less reliable.

Adult↗

Colorimetric quantitation of albumin in microliter volumes of serum.

Various non-immunochemical approaches to the quantitation of albumin in serum are reviewed. Salt fractionation techniques are unreliable, with substantial errors in estimating hypoalbuminemic states. Electrophoresis displays biases owing to irregular dye-binding or to densitometric scanning of irregular globulin bands. Currently, the most reliable colorimetric procedure for albumin quantitation is the rapid reaction with bromcresol green. By measuring final absorbance within fifteen seconds of mixing serum with reagent, the interference of globulins is eliminated. A microscale (5 microliter serum) rapid reaction for albumin assay has been developed; it can be readily automated on kinetic or centrifugal analyzers.

Bromcresol Green↗

Therapeutic drug monitoring: measurements of antiepileptic and barbiturate drug levels in blood by gas chromatography with nitrogen - selective detector.

The nitrogen-specific detector for gas chromatography consists of a non-volatile rubidium silicate bead, around which nitrogen-containing compounds are pyrolyzed. Speed, sensitivity, specificity, accuracy, small sample size and minumum sample handling are characteristics of the nitrogen detector that render it superior to conventional gas chromatographic detectors. The detector has been utilized to effect a simple and rapid quantitation of allobarbital, amobarbital, butabarbital, heptabarbital, pentabarbital, phenobarbital and secobarbital, plus the anticonvulsants diphenylhydantoin and primidone. Extraction of the drugs from acidified serum into organic solvent containing internal standard is followed by oncolumn methylation with methanolic trimethylphenyl ammonium hydroxide. The drugs, separated on a column of 3 percent OV-101 on Gas-Chrom Q, 100-120 mesh are readily quantitated by simple calculations based on peak-height ratios. Therapeutic drug monitoring is discussed in relation to recent concepts of drug-protein binding, drug-drug interactions, drug biotransformation and problems of multiple drug therapy.

Amobarbital↗