PubMed Health⌕ Search

Biomedical subjects

D P NaBadalung

Publications and source records attributed to D P NaBadalung.

8 recordsLinked to original sources

Prosthodontic rehabilitation of an anhidrotic ectodermal dysplasia patient: a clinical report.

This clinical report describes the characteristics and prosthodontic restoration of a young male patient with anhidrotic ectodermal dysplasia. With proper care and prosthodontic treatment, the patient can enjoy a relatively normal life. It is important that the patient and his parents fully understand the dental problems related to his physiologic and psychologic conditions. The need for continued dental treatment is necessary.

Anodontia↗

A universal boxing procedure: irreversible hydrocolloid and magnetic strip.

The goal of impression making is an accurate cast. The boxing procedure is a crucial step to preserve the details of the final impression especially of the vestibular area. This article describes an alternative boxing procedure that is compatible with all impression materials, is efficient, simple, inexpensive, and practicable.

Alginates↗

Comparison of bond strengths of three denture base resins to treated nickel-chromium-beryllium alloy.

PURPOSE: In-vitro bond strengths of 3 denture base resins (Trutone, Lucitone 199, and Triad) to a nickel-chromium-beryllium removable partial denture alloy (Ticonium) were tested with 3 surface pretreatments: sandblast, acid etch, and Rocatec (silica blasting), with or without primers (Dentsply, CR inlay cement, and Super Bond). MATERIAL AND METHODS: Lucitone 199 denture base resin bonded to the nonprimed sandblasted alloy specimen served as the control group. Alloy specimens were prepared, surface treated, and primed or not primed with primer. The treated specimens were then packed and processed with the denture base resin. Bonded specimens were stored in the distilled water at 37 degrees C for 24 hours, and then debonded in tension. The force at which the bond failed was noted, and bond strength was calculated in megapascals (MPa). Five replications for each condition (180 specimens total) were tested. RESULTS: Significant differences in bond strength were observed with primer, the most important factor, followed by pretreatment and denture base resin. Without primer for all 3 denture base resins, the Met-Etch and Rocatec treated group showed significantly higher bond strengths than the sandblasted groups. For Trutone denture base resin, nonprimed treated groups produced significantly higher bond strength than those for the other 2 denture base resin, nonprimed treated groups produced significantly higher bond strength than those for the other 2 denture base resins. The control group had zero bond strength. For Dentsply primer, the Rocatec treated group bonded to Lucitone 199 resin produced the highest bond strength value (14.8 +/- 1.8 MPa). For CR inlay cement, the Met-Etch and Rocatec treated groups for Lucitone denture base resin demonstrated the highest bond strength (19.3 +/- 4.8 MPa, and 19.3 +/- 1.8 MPa, respectively). For super Bond primer, the Met-Etch treated group for Trutone resin demonstrated the highest bond strength (19.8 +/- 6.2 MPa). CONCLUSIONS: Without primer, the control had the lowest bond strength (0 MPa), and the Trutone groups showed the highest bond strength (11.7 +/- 4.1 MPa). Met-Etch and Rocatec treated groups produced higher bond strengths than the sandblasted groups. The primed specimens demonstrated significantly higher bond strengths than nonprimed specimens, except for Trutone resin, for which primed specimens produced lower bond strengths than the nonprimed specimens.

Acid Etching, Dental↗

Laser welding of a cobalt-chromium removable partial denture alloy.

STATEMENT OF PROBLEM: The electric alloy brazed joints of removable partial denture alloys have failed frequently after routine usage. PURPOSE: A technique providing higher joint strengths was investigated. This investigation compared the tensile strengths of electric-brazed and laser-welded joints for a cobalt-chromium removable partial denture alloy. MATERIAL AND METHODS: Twenty-four cobalt-chromium standard tensile testing rods were prepared and divided into three groups of eight. All specimens in the control group (group 1) were left in the as-cast condition. Groups 2 and 3 were the test specimens, which were sectioned at the center of the rod. Eight specimens were joined by using electric brazing, and the remaining specimens were joined by using laser welding. After joining, each joint was ground to a uniform diameter, then tested to tensile failure on an Instron universal testing machine. Failure loads were recorded and fracture stress calculated. Statistical analysis was applied. RESULTS: The student-Newman-Keuls test showed a highly significant difference between the joint strengths of the as-cast control specimens, the electric-brazed and laser-welded joints. CONCLUSIONS: The tensile strengths of the as-cast joints were higher than those for the laser-welded joints, and both were higher than the electric-brazed joint strengths.

Analysis of Variance↗

Effectiveness of adhesive systems for a Co-Cr removable partial denture alloy.

PURPOSE: In vitro bond strengths of traditional denture base acrylic resin (Lucitone 199) to a cobalt-chromium partial denture alloy (J.D. Partial Denture Alloy) were tested using two surface pretreatments (sandblast, sandblast and electrochemical etch) with three adhesive primers: Lee Metal Primer, Acrylic Solder, and CR Inlay cement. A sandblasted group with no primer served as the control. MATERIALS AND METHODS: The alloy specimens (8.0-mm bonding diameter) were cast and invested to receive a traditional denture base resin after surface treatments (sandblasted, and sandblasted-electrochemically etched) and application of adhesive primers. The bonded specimens were stored in distilled water at 37 degrees C for 24 hours and divided into two groups. The first group was debonded in tension on a testing machine at a cross-head speed of 0.05 cm/min. The second group was subjected to thermocycling of 1,000 cycles and then tested for tensile bond strength. The force at which the bond failed was recorded, and the bond strength was calculated in megapascals (MPa). The sites of bond failure were examined, quantified under (20x) magnification, and recorded. Ten specimens were evaluated for each experimental condition for a total of 160 specimens. Data were analyzed by ANOVA with a factorial design. Means were compared by Tukey intervals at the 0.05 significance level. RESULTS: Significant differences in bond strength were observed, with primers being the most important factor, followed by pretreatment and storage and thermocycling with significant interactions. Sandblasted-electrochemically etched alloy with primers more effectively enhanced bond strength of the denture base resin to the treated alloy than sandblasted alloy with primers. Thermocycling had a greater effect on bond strength of the specimens with Acrylic Solder when compared with Lee and CR Inlay primers. The highest bond strengths (> or = 18.0 MPa) were observed for the conditions involving electrochemical etching and the priming with CR Inlay cement (both after 24 hours and thermocycling of 1,000 cycles). For primed specimens, the bond failures occurred cohesively within the primers or the denture resin and adhesively between the primers and the denture base resin, or between primers and alloy. For nonprimed, the bond failures occurred adhesively at the denture base resin-metal interface. CONCLUSIONS: Nonprimed specimens (both sandblasted and electrochemically etched) had lowest bond strength (0.4 +/- 0.1 MPa; 0.3 +/- 0.4 MPa). The bond strengths of the primed treated specimens were improved significantly. The CR Inlay-treated specimens exhibited the highest bond strength (20.6 +/- 6.3 MPa). After thermocycling for 1,000 cycles, the bond strengths of the specimens were significantly lower than the bond strengths of the specimens after 24 hours.

Acrylic Resins↗

Comparison of bond strengths of denture base resins to nickel-chromium-beryllium removable partial denture alloy.

PURPOSE: In vitro bond strengths of a traditional denture base resin (Lucitone 199) and three adhesive denture base resins (Meta-Dent, Meta-Fast with liner, and Meta-Fast without liner) to treated nickel-chromium-beryllium (Ni-Cr-Be) partial denture alloy were tested with four alloy surface pretreatments (sandblast, Met-etch, Rocatec with silane, and Rocatec without silane), with or without primer (Dentsply). The Lucitone 199 resin bonded to the nonprimed sandblasted group was the control group. The hypothesis was the use of alloy pretreatments and/or primer does not improve the bond strength of denture base resins to sandblasted Ni-Cr-Be partial denture alloy. MATERIAL AND METHODS: Primed and nonprimed bonded specimens were prepared and finished, stored in 37 degrees C distilled water for 24 hours, then debonded in tension on a testing machine. The bond strength was calculated in megapascals (MPa). Five specimens were prepared and tested for each experimental condition, both with and without primer, for a total of 160 specimens. RESULTS: For three-way analysis of variance, the main effects of resins and treatment were statistically significant (p < 0.05), but the main effect of primer was not statistically significantly (p > 0.05). Without primer, the control group had the lowest bond strength (0 MPa). The three adhesive resin groups produced significantly higher bond strengths than the Lucitone resin groups. For the treated groups, nearly all sandblasted groups produced significantly lower bond strength than the other three treated groups. Meta-Dent to Met-etch treated group had the highest bond strength (23.9 MPa). With primer, the bond strengths of the Lucitone resin groups were significantly higher than the nonprimed groups, and the Lucitone resin-primed Rocatec treated group had the highest bond strength (14.8 MPa). For the three adhesive denture base resins, nearly all primed treated groups had significantly lower bond strengths than nonprimed groups. CONCLUSIONS: Without primer, the Lucitone resin-sandblast treated group (control) had the lowest bond strength (0 MPa). The Meta-Dent denture base resin with the Met-etch treated group had the highest bond strength (23.9 MPa). With primer, the Lucitone resin-primed Rocatec-silane treated group had the highest bond strength (14.8 MPa). For the adhesive denture base resins, nearly all bond strengths of the primed treated groups were significantly lower than the values of the nonprimed groups.

Acid Etching, Dental↗

Frictional resistance of removable partial dentures with retrofitted resin composite guide planes.

Frictional resistance to the dislodging forces of a removable partial denture with and without resin composite retrofitted guide planes was compared in vitro. Six master models of four natural teeth, each simulating a Kennedy Class III modification 1 arch, were used. Guide planes were prepared, and 18 cobalt-chromium removable partial denture frameworks without clasps were fabricated. Three resin composite materials were applied to the guide planes as retrofitting materials. Following this, the resistance to dislodgment of the removable partial denture framework was evaluated under cyclic dislodgment, and the resistance to dislodgment before and after resin composite retrofitted guide planes was compared. The dislodgment force was recorded every 500 cycles. Testing was concluded when the dislodging force value reached 50% of the initial value. There was a significant difference between the dislodging forces with and without retrofitted guide planes. Higher dislodging forces were recorded when resin composite retrofitted guide planes were used. Z100 was the most effective retrofitting material under cyclic dislodgment, and Heliomolar and Herculite XR performed similarly.

Acrylic Resins↗