PubMed Health⌕ Search

Biomedical subjects

D P Nicolella

Publications and source records attributed to D P Nicolella.

4 recordsLinked to original sources

Microstrain fields for cortical bone in uniaxial tension: optical analysis method.

This study employed an optical strain measurement method, called microdisplacements by machine vision photogrammetry (DISMAP), to measure both the global and local strain fields in microtensile specimens of cortical bone subjected to controlled uniaxial tension. The variation of local maximum principal strains was measured within the gauge region of samples as a function of applied tensile stress during testing. High gradients of local strain appeared around microstructural features in stressed bone even while the global strain for the entire gauge region showed a strong linear correlation with increasing tensile stress (r2 = 0.98, p < 0.0001). The highest local strain around microstructural features in bone was 11.5-79.5 times higher than the global strain.

Animals↗

Microstructural strain near osteocyte lacuna in cortical bone in vitro.

Mechanical factors affect bone remodeling such that increased mechanical demand results in net bone formation, whereas decreased demand results in net bone resorption. Two proposed mechanical signals are stress-generated fluid flow forces acting on cells and bone matrix deformation itself. A prominent current theory is that bone cells are more responsive to fluid flow than to mechanical strain. Recent experiments support this conclusion: bone cells increase their production of osteopontin (OPN) mRNA, prostaglandin (PGE(2)), and nitric oxide (NO) in response to fluid flow in contrast to cells stimulated by mechanical strain levels similar to those measured in vivo. However, when cells are subjected to substrate strains levels many times greater than those measured in vivo, increased biological activity again results. We assert that it is neither fluid flow nor matrix deformation per se, but rather the resulting cell deformation that causes cell biological response. Machined specimens of undamaged bovine cortical bone were subjected to increasing levels of macroscopic strain while observed under an optical microscope at 220X. Continuum level strain was measured using a standard foil strain gauge attached to the back of the specimen and ranged from 500 to 6,000 microstrain. Images of the specimen surface at each strain level were captured. To determine the level of osteocyte deformation that results from fluid flow in vitro, MLO-Y4 cells were cultured on collagen coated 190 cm2 plastic sheets and subjected to steady fluid flow at 16 dynes/cm(2). Images representing the initial undisturbed cell configuration and the configuration of the cells after ten minutes of fluid flow were acquired from a videotape of the flow experiment. The captured unloaded vs. loaded image pairs were analyzed to determine the local deformation and strain fields using a digital stereoimaging system. When subjected to a nominal continuum strain level approximately equal to that measured in humans in vivo during rigorous activity (2,000 microstrain), the local, osteocyte level strains can be as high as 12,000 to 15,000 microstrain (1.2% to 1.5%). Average osteocyte strains due to fluid flow in vitro increase from 7,972 microstrains after 16 seconds of flow to 22,856 microstrains after 64 seconds of flow. In contrast, maximum strains measured in vivo are approximately 1,800 microstrain in humans and up to 3,000 microstrain in other species. These data may help to explain why bone cells are more sensitive to fluid flow than substrate strain; fluid forces result in cell deformations much higher than those considered to be "physiological".

Journal Article↗

Primary adult human bone cells do not respond to tissue (continuum) level strains.

Bone adapts to its mechanical environment, and, since the late 1800s, investigators have presumed that this adaptation relates to strain magnitude. Indeed, overwhelming evidence supports the view that either strain or some strain-related quantity stimulates bone adaptation or remodeling. Virtually all investigators, implicitly or explicitly, assume that the level of strain magnitude responsible for bone adaptation is that measured by strain gauges in vivo (i.e., 100-2500 microstrain) and that bone cells are directly deformed by strained matrix. We present evidence that bone cell deformation in this range does not cause bone adaptation. First, bone cells in vitro typically do not respond to average (continuum) levels of strain magnitude. Second, bone cells in vitro do respond to fluid flow-induced shear stresses in these ostensible physiological ranges. Third, in vivo strain magnitudes presumed to stimulate remodeling reflect only averages, and not local peaks, which are 2-15 times higher. Thus, we hypothesize that sensing cells do not respond to levels of strain presumed to be physiological.

Adaptation, Physiological↗

Machine vision photogrammetry: a technique for measurement of microstructural strain in cortical bone.

Understanding local microstructural deformations and strains in cortical bone may lead to a better understanding of cortical bone damage development, fracture, and remodeling. Traditional experimental techniques for measuring deformation and strain do not allow characterization of these quantities at the microstructural level in cortical bone. This study describes a technique based on digital stereoimaging used to measure the microstructural strain fields in cortical bone. The technique allows the measurement of material surface displacements and strains by comparing images acquired from a specimen at two distinct stress states. The accuracy of the system is investigated by analyzing an undeformed image set; the test image is identical to the reference image but translated by a known pixel amount. An increase in the correlation sub-image train parameter results in an increase in displacement measurement accuracy from 0.049 to 0.012 pixels. Errors in strain calculated from the measured displacement field were between 39 and 564 microstrain depending upon the sub-image train size and applied image displacement. The presence of a microcrack in cortical bone results in local strain at the crack tip reaching 0.030 (30,000 microstrain) and 0.010 (10,000 microstrain) near osteocyte lacunae. It is expected that the use of this technique will allow a greater understanding of bone strength and fracture as well as bone mechanotransduction.

Animals↗