PubMed Health⌕ Search

Biomedical subjects

D Payne-Bose

Publications and source records attributed to D Payne-Bose.

5 recordsLinked to original sources

Effects of age on lactose malabsorption in Oklahoma Native Americans as determined by breath H2 analysis.

Breath H2 excretion was used to determine lactose malabsorption in 30 health females and 30 healthy males between the ages of 3 and 64 yr who were at least 7/8 Native American. The test meal consisted of 5 ml reconstituted nonfat dry milk (0.25 g lactose) per kg of body weight. On the basis of breath H2 tests in 15 control subjects with normal oral lactose tolerance tests, a response factor of 20 ppm was selected as the upper limit for lactose absorbers. Of the 60 subjects in the study group, 36 (60%) were classified as lactose malabsorbers since they had a response factor of 20 ppm or greater of breath H2. Only 3 of 20 children (15%) who were under the age of 12 yr were nondigesters of the small lactose dose used in this study. Approximately 82 percent (82.5%) of subjects who were 13 yr and older were lactose malabsorbers. Adolescence appears to be the period in which malabsorption of lactose becomes evident in Native North Americans.

Adolescent↗

Milk and lactose-hydrolyzed milk.

Seven females 18 to 26 years old (mean 23 years) who were lactose malabsorbers as determined by a lactose tolerance test were given two different test meals: 5 ml/kg body weight reconstituted nonfat dry milk and 5 ml/kg body weight reconsituted nonfat dry milk in which 92% of the lactose had been hydrolyzed to glucose and galactose. Lactose malabsorption was determined by the breath H2 test. Tests were done in duplicate for a total of 28 tests. Whether a 3-hr test period of a 5-hr test period was used, the average breath H2 response after the lactose-hydrolyzed nonfat dry milk test meals was significantly lower (P less than 0.002) than the average breath H2 response after the nonfat dry milk test meals. There were significant differences among individual responses (P lless than 0.06 for the 3-hr test period and P less than 0.09 for the 5-hr test period), and no significant differences between duplicate test days.

Adolescent↗

A sampling technique for organic components in human breath.

An analytical sampling system was developed for trace organic components in breath. The sampling system was designed to maximize analyte concentrations while minimizing interference from exogenous contamination. Details of the sampling system design and its operation are presented.

Breath Tests↗