PubMed HealthSearch

Biomedical subjects

D Poussart

Publications and source records attributed to D Poussart.

11 recordsLinked to original sources

Complex admittance of Na+ conduction in squid axon.

The complex admittance, Y(p), of squid axon was measured (4--1000 Hz) during step voltage clamp to obtain linear data on Na+ conduction. Y(p) is used as a spectroscopic tool to identify Na+ and K+ conduction, which dominate Y(p) at low frequencies and can be separated from each other and from the static capacitance. Na+ conduction is readily distinguishable from K+ conduction in that it produces a steady-state negative conductance. The admittance of the Na+ system can show an anomalous resonance or an antiresonance depending on whether the net shunt conductance is negative or positive. Use of the Na+ negative conductance to neutralize leakage yields a measurement of dielectric capacitance at low frequency. A 90 degrees phase angle suggests that the capacitance is ideal.

Animals

Asymmetry currents and admittance in squid axons.

The complex admittance of squid (Loligo pealei) axon was measured rapidly (within 1 s) with pseudo-random small signals and discrete Fourier transform techniques under guarded, "space-clamp" conditions and during suppression of ion conduction. Asymmetry currents were measured by paired step clam pulses of +/-70 mV from a holding potential of -97 mV and gave an apparent capacitance of 0.36 muF/cm2. However, the admittance data showed no change in capacitance at holding potentials from -97 to -67 mV and gave a decrease of 0.07 of 0.15 muF/cm2 at -37 mV. The failure to observe a capacitance increase at low membrane potentials suggests the following possibilities: (a) the asymmetry current is a displacement current that inactivates completely with time, and (b) the asymmetry current is not a displacement current and arises from large signal effects (i.e., delayed nonlinearity in ionic current) on the membrane.

Animals

Phonocardiogram spectral analysis simulator of mitral valve prostheses.

Spectral analysis of sounds produced in vitro by mitral valve prostheses placed in a specially designed flow simulator has been carried out using a short-time Fourier representation of the recorded signal. Time variations of power spectra are displayed as a three-dimensional plot. Sounds produced by three types of valves, namely ball and cage, tilting disk and porcine valves, were analysed. Each valve type produced a characteristic spectrogram, and, for a given valve, spectrograms were reproducible to within a margin of 5 dB. The simulator may be used to detect structural deficiencies and functional abnormalities of prosthetic heart valves. In addition to quantifying the noise level of mechanical valves, the system may be used for quality control purposes to identify faulty valves.

Equipment Design