PubMed Health⌕ Search

Biomedical subjects

D Pradeau

Publications and source records attributed to D Pradeau.

At least 19 recordsLinked to original sources

Sensitive quantification of diphemanil methyl sulphate in human plasma by liquid chromatography-tandem mass spectrometry.

A simple detection system with a high-performance liquid chromatography (HPLC) with positive ionisation-tandem mass spectrometry (ESI-MS/MS) for determining diphemanil methylsulphate (DMS) levels in human plasma using 4-diphemanylmethylene,1-methylpiperidine as an internal standard (I.S.), is proposed. The acquisition was performed with the multiple reactional monitoring (MRM) mode, by monitoring the transitions: m/z 278>262 for DMS and m/z 263>247 for the I.S. The method involved a simple single-step deproteinisation with acetonitrile. The analyte was chromatographed on a Zorbax C18 reversed-phase chromatographic column by isocratic elution with 10(-3)M ammonium acetate and 10(-3)M hexafluorobutyric acid, adjusted to pH 7.0 with ammoniac/acetonitrile (40/60, v/v). The results were linear over the studied range (0.5-50.0 ng mL(-1)) and the total analysis time for each run was 10 min. The mean extraction apparent recoveries expressed at the 95% intervals of confidence were 94-104% for DMS and 92-106% for the I.S. The intra- and inter-assay precisions were 4.6-8.4% and 2.9-10.6%, respectively. The limit of quantification was 0.15 ng mL(-1). The devised assay was successfully applied to the residual concentrations monitoring in infant.

Chromatography, High Pressure Liquid↗

Stability studies of ionised and non-ionised 3,4-diaminopyridine: hypothesis of degradation pathways and chemical structure of degradation products.

3,4-Diaminopyridine is used to treat some symptoms met in Lambert-Eaton myasthenia syndrome. It was shown efficient to reduce a form of variable muscle weakness and fatigability typical of the disease and correlated to a block of acetylcholine release. In France, 3,4-diaminopyridine is nowadays given to patients under capsules form and the status of hospital preparation. Whatever the diluant used in the formulation, the stability period could not exceed 12 months. Preliminary studies were made on a salt form in order to test the influence of various stress factors and determine if there is interaction between them. From this study, the most influent stress condition, presence of hydrogen peroxide, was selected and a comparative study was performed to compare the stability of molecular and salt species. Solutions of each species were exposed to 5 or 15% of hydrogen peroxide and analyzed at 8, 24, 72 and 216 h of degradation by HPLC-UV. Fractions of detected impurities were purified and collected by semi-preparative HPLC-UV and analyzed by HPLC-UV-ESI-MS and IR spectroscopy in order to determine their structure hypotheses. Theses experiments demonstrate that the salt species were more stable under oxidative stress condition than molecular species. The two main degradation products were collected and identified as 4-amino, 3-nitropyridine and 3,4-diaminopyridine-N-oxide when the molecular form was degraded whereas only 4-amino, 3-nitropyridine was found in less quantity in the salt solutions. Nitrogen pyridine and pyridine amine could not easily be oxidized by hydrogen peroxide in salt comparatively to molecular species due to the lone pair of electron engaged in a bound with hydrogen in the first case and by resonance change of the pyridine in the second case. This modification of structure promoted different pathways of degradation for the salt form which are more dependent of energy. Owing to the better stability of the salt species, a new pharmaceutical form containing it was developed to assess its stability under ICH standard conditions allowing an industrial manufacture of this drug.

4-Aminopyridine↗

[Migration of plastic material components into food].

Despite constant improvement in the control of interactions between packaging materials and food, the problem remains worrisome. The theoretical study of various type of reactions (absorption, migration, permeation) as well as influential factors are described. The analysis of the French regulation is detailed with a special focus on the January 2003 order. After the description of assay protocols using simulated fluids, the main issues are studied and the future of manufacturing processes and materials is presented.

Absorption↗

Determination of A 3,4-diaminopyridine in plasma by liquid chromatography with electrochemical detection using solid-phase extraction.

In order to quantify a small amount of a drug, 3,4-diaminopyridine (3,4-DAP), in animal plasma samples, an analytical method was developed. It involved an extraction of 3,4-DAP and phenylephrine, used as internal standard (IS), from plasma with solid-phase extraction (SPE) on C18 cartridges. This analytical method is a hyphenated technique based on high-performance liquid chromatography with electrochemical detection (HPLC-EC) whose purpose is to obtain first a sensitive method and second a satisfying separation between 3,4-DAP and phenylephrine. The analytical method is accurate, specific, and linear between 10 and 500 g of 3,4-DAP per litre. The recovery of 3,4-DAP is estimated at 70.8% with a 95% confidence interval of (66.0 -75.6%). Intermediate precision was evaluated on three quality control samples; the intra-day precision was estimated at 13.5, 9.1, 7.8% and the inter-day precision at 17.9, 8.4, 9.3%. The limit of quantification of the method was evaluated at 10 g l-1. First toxicokinetic parameters determined on dogs plasma samples after one 3,4-DAP oral administration of 1 mg kg-1 were: Cmax=395.7 microg l-1; Tmax =15 min; t1/2=113.6 min; Clearance/F=16.8 ml kg-1 min-1 and Vd/F=2.7 l kg -1.

4-Aminopyridine↗

LC determination of diphemanil methylsulfate: application to stability study of stored pharmaceutical formulations.

Diphemanil methylsulfate (DMS) is a synthetic antimuscarinic agent classically used in infants for vagal hypertonia-related symptoms. A normal-phase, isocratic liquid chromatographic method was developed for the quantitative determination of DMS in bulk drugs and in pharmaceutical forms. The method has been completely validated and robustness of this method has been studied. The limit of detection (LOD) for DMS impurities namely, impurity 1 and 2 were found to be 11 and 46 ng/ml. The limit of quantitation (LOQ) was found to be 49 and 139 ng/ml for impurity 1 and 2, respectively. The stability studies have been performed for 2 and 10 mg DMS tablets subjected at various temperatures: 25 degrees C (long term storage condition) and 40 degrees C (accelerated storage condition) for 18 and 6 months, respectively. At 25 degrees C, the samples were found to be stable for the study period. At 40 degrees C, 2 and 10 mg DMS tablets showed degradation up to 5 and 10% over a 6-month period.

Algorithms↗

Speciation of arsenic and selenium compounds by ion-pair reversed-phase chromatography with electrothermic atomic absorption spectrometry. Application of experimental design for chromatographic optimisation.

An off-line system is proposed consisting of ion-pair reversed-phase liquid chromatography, collections of fractions at the outflow of the column and furnace atomic absorption spectrometry. The so-called system allowed determination of both arsenic and selenium species mainly found in the environment and in mammals (arsenite, arsenate, monomethylarsonate, dimethylarsinate, selenite, selenate, selenocystamine, selenocystine, selenomethionine and selenoethionine). In order to study the retention behaviour of these compounds and to estimate the optimal conditions for the chromatographic separation, central composite designs were used to evaluate the influence of the eluent parameters such as pH, tetrabutylammonium phosphate (TBA) concentration and sodium hydrogenphosphate amounts. The retention factors of each species and the selectivity were established as response criteria. Response surfaces and isoresponse curves were drawn from the mathematical models and enabled one to determine the optimal conditions and to visualise the method robustness. The predicted optimal zone was situated at pH 5.5-6.5, 4.0 mM Na2HPO4 and 3.0-4.0 mM TBA. Regression models suggested linearity for the studied compounds in the range 25-200 microg selenium and arsenic per litre investigated.

Arsenic↗

Stability of stored methacholine solutions: study of hydrolysis kinetic by IP-LC.

Methacholine chloride is a powerful cholinergic bronchoconstrictor agent used during bronchial airway hyper-responsiveness diagnosis. Methacholine is susceptible to hydrolysis in aqueous solutions in acetic acid and beta-methylcholine. In the present work, kinetics of hydrolysis with different solvents (water and phosphate-buffered saline (PBS) pH 7.4) at different temperatures have been studied using a newly developed high-performance liquid chromatography. At 4 degrees C, kinetic determination of hydrolysis in methacholine chloride solutions (50 mg/ml) shows no hydrolysis in either aqueous or phosphate-buffered solutions over a 40-day period. At 30 degrees C, concentration of unbuffered methacholine chloride solutions remained unchanged, but buffered methacholine chloride solutions have degradation up to 5.5% over a 40-day period. At 40 degrees C, concentration of unbuffered methacholine chloride has degradation up to 5% and buffered methacholine chloride solutions have degradation up to 10% over a 40-day period. Methacholine chloride solutions are susceptibly to be used in hospital pharmacy at different concentrations. We have studied pH and osmolality for methacholine solutions prepared with different diluents potentially used in hospital pharmacies, i.e. deionized water, 0.9% NaCl and PBS pH 7.4. We have demonstrated that methacholine solutions prepared with deionized water at 50 mg/ml and diluted with PBS pH 7.4 from 5 to 40 mg/ml are isoosmotic and potentially available for inhalation tests to measure non-specific bronchial hyper-responsiveness.

Bronchoconstrictor Agents↗

Application of central composite designs for optimisation of the chromatographic separation of monomethylarsonate and dimethylarsinate and of selenomethionine and selenite by ion-pair chromatography coupled with plasma mass spectrometric detection.

Central composite designs (CCDs) were used in the study of the ion-pair chromatographic separation of arsenic and selenium species in tap water: monomethylarsonate, dimethylarsinate, selenomethionine and selenite. The ternary eluent consisted of tetrabutylammonium phosphate (TBA), sodium hydrogenphosphate (Na2HPO4) and 1% acetonitrile. CCD allowed the investigation of the influence of the eluent parameters, which varied from 0.5 to 4.2 mmol l-1 Na2HPO4, 0.5 to 4.2 mmol l-1 TBA and pH 4.9 to 8.2, on the capacity factors (k') of arsenic and selenium compounds. Furthermore, another mathematical model that permitted the variation of the chromatographic selectivity of species, computed from their retention data to be followed, was investigated. This showed the ability to locate the optimum conditions within the experimental design, so that arsenic and selenium species could be simultaneously quantified with good efficiency and resolution. A comparison between the predicted and the experimental response values was made in order to assess the prediction quality of the model. Response surfaces and isoresponse curves obtained from the mathematical models allowed the determination of the optimum chromatographic conditions and the robustness of the method. The predicted optimum zone allowing satisfactory determination of both arsenic and selenium compounds was pH 5.5-6.5, 2.5 mmol l-1 Na2HPO4 and 3.0-4.0 mmol l-1 TBA.

Journal Article↗

On-line reversed-phase liquid chromatography hydride generation emission spectrometry: speciation of arsenic in urine of patients intravenously treated with As2O3.

Hydride generation inductively coupled plasma-atomic emission spectrometry (HG ICP-AES) was used as a continuous detection system for the determination of arsenic in the eluate from a high-performance liquid chromatographic (HPLC) system. Four arsenic species [arsenite As(III), arsenate As(V), monomethylarsonate (MMA), and dimethylarsinate (DMA)] present in the urine samples of patients treated intravenously with arsenite, were analyzed separately by HPLC-HG-ICP-AES using a non-polar C18 column. This analytical method allowed the sensitive determination of the arsenic species in the submicrogram per liter range. Urine samples collected on different days after arsenite administration were found to contain arsenite predominantly--monomethylarsonate and dimethylarsinate were also detected.

Arsenic↗

Determination of total cysteamine in human serum by a high-performance liquid chromatography with fluorescence detection.

A convenient, reliable and rapid method for determination of total cysteamine in human plasma by high-performance liquid chromatography with fluorescence detection is reported. This assay involves reduction of samples with dithiothreitol, derivatization of total cysteamine by addition of monobromobimane and protein precipitation by perchloric acid. The calibration curve was linear in the range 2-150 nmol ml-1 and the detection limit was 0.5 nmol ml-1. This method was successfully applied for a pharmacokinetic study of three cysteamine derivatives in healthy volunteers without any interference from coexisting substances.

Biological Availability↗

Study protocol: stability of morphine injected without preservative, delivered with a disposable infusion device.

BACKGROUND AND OBJECTIVE: Morphine hydrochloride, a major analgesic drug, is being increasingly administered using portable disposable infusion devices. The objective of this study was to investigate the stability of morphine in such a system at two concentrations (2.50 and 5.00 mg/ ml) over a 30-day period. METHOD: High-performance liquid chromatography of stored morphine solutions. RESULTS: The best stability was observed with disposable infusion devices filled with a morphine solution containing sodium metabisulphite as a preservative. No breakdown products were detected after 1 month of storage at room temperature, in light or darkness. On the other hand, 2.50 and 5.00 mg/ml morphine solutions without sodium metabisulphite, stored in the infusion device led to the formation of 0.205% and 0.235% of pseudomorphine, respectively, after 6 days of storage in the light, and 1.50% and 0.94% after 30 days storage. CONCLUSION: Morphine hydrochloride solutions stored in disposable infusion devices degraded very slowly, particularly when preserved with sodium metabisulphite. The solutions are stable over 5 days, the maximum period of storage normally required when using disposable infusers.

Analgesics, Opioid↗

[Extemporaneous production of gas standard for the determination of carbon monoxide, hydrogen cyanide and ethylene oxide].

This paper describes a new calibration method for headspace chromatographic assay of carbon monoxide, hydrogen cyanide and ethylene oxide. The calibration method is based on the in situ formation of gas in a closed system in order to avoid, the dangerous handling of pure gas or harmful substances. In the first method, the standardization is based on the in situ formation of carbon monoxide by the reaction of hot concentrated sulfuric acid with formic acid. In the second method, the standardisation is based upon the in situ reduction of ethyl thiocyano by dithiothreitol to produce HCN. In the third method, the standardisation is based upon the in situ chemical transformation of 2-chloro-ethanol into ethylene oxide with a recovery of about 60%.

Carbon Monoxide↗

Efficient phosphate binding using a combination of gluconolactate and carbonate calcium salts.

Although renal-failure-related hyperphosphataemia can be corrected by various phosphate binders, there remains a need for safer and more efficient formulations to precipitate phosphate. This work describes both a theoretical approach and a phosphate precipitation test in order to design efficient binding calcium salts formulations. The results show that the combination of a soluble calcium salt (the gluconolactate) and a proton-consuming calcium salt (the carbonate) can precipitate phosphate effectively. Furthermore, the theoretical computations correlate well with the ability of the salt to bind phosphate in vitro.

Acetates↗

Simultaneous determination of water-soluble vitamins by over-pressure layer chromatography and photodensitometric detection.

An over-pressure layer chromatographic procedure with photodensitometric detection for the simultaneous determination of water-soluble vitamins in multivitamin pharmaceutical preparations was developed and evaluated. The method uses high-performance TLC (HPTLC) plates with silica gel as the thin-layer, and an n-butanol:pyridine:water mixture (50:35:15, v/v/v) as mobile phase at a rate of 0.25 mL/min for baseline separation. The quantitation was carried out without derivatization (vitamin B1, vitamin B2, vitamin B6, folic acid, nicotinamide, vitamin C) or after spraying ninhydrin reagent (calcium pantothenate) or 4-dimethylaminocinnamaldehyde (vitamin B12, biotin). This was applied to the analysis of multivitamin solutions. Satisfactory relative standard deviations and good recovery were obtained for all the vitamins examined. It was concluded that this method is fast, accurate, specific, and suitable for routine quality control use.

Absorptiometry, Photon↗