PubMed Health⌕ Search

Biomedical subjects

D Prior

Publications and source records attributed to D Prior.

12 recordsLinked to original sources

Improved outcomes from a comprehensive management system for heart failure.

AIMS: Congestive heart failure (CHF) is associated with a high readmission rate after diagnosis. We assessed the ability of a comprehensive management program (CMP) for CHF to reduce readmissions with secondary endpoints of improving quality of life, exercise capacity and targeted drug doses. METHODS AND RESULTS: Patients (pts) with: New York Heart Association Class (NYHA) III or IV CHF; left ventricular ejection fraction <40%; and stable outpatient therapy were assigned to a CMP of cardiology assessment intensive education and referral to a tailored exercise program. Forty-two pts (35 M, 7 F, mean age 54 years, S.D. 12 years) were enrolled. Two pts were transplanted, two died during follow-up and two were lost to follow-up. Hospital admissions were reduced by 87.2%, (mean 1.05, S.D. 0.98, admissions per pt to mean 0.08, S.D. 0.28, admissions per pt at 6-month follow-up; P<0.0001). ACE-inhibitor dose increased by 42% (P<0.0008) and beta-blocker dose increased by 61% (P<0.0001). NYHA Class, 6-min walk and quality of life scores all improved significantly (P<0.0001). CONCLUSION: A CMP improves QOL and exercise capacity as well as substantially reducing hospital admissions in CHF pts. This study validates the benefit of intensive outpatient care of CHF.

Aged↗

Estimation of left ventricular operating stiffness from Doppler early filling deceleration time in humans.

Shortened early transmitral deceleration times (E(DT)) have been qualitatively associated with increased filling pressure and reduced survival in patients with cardiac disease and increased left ventricular operating stiffness (K(LV)). An equation relating K(LV) quantitatively to E(DT) has previously been described in a canine model but not in humans. During several varying hemodynamic conditions, we studied 18 patients undergoing open-heart surgery. Transesophageal echocardiographic two-dimensional volumes and Doppler flows were combined with high-fidelity left atrial (LA) and left ventricular (LV) pressures to determine K(LV). From digitized Doppler recordings, E(DT) was measured and compared against changes in LV and LA diastolic volumes and pressures. E(DT) (180 +/- 39 ms) was inversely associated with LV end-diastolic pressures (r = -0.56, P = 0.004) and net atrioventricular stiffness (r = -0.55, P = 0.006) but had its strongest association with K(LV) (r = -0.81, P < 0.001). K(LV) was predicted assuming a nonrestrictive orifice (K(nonrest)) from E(DT) as K(nonrest) = (0.07/E(DT))(2) with K(LV) = 1.01 K(nonrest) - 0.02; r = 0.86, P < 0.001, DeltaK (K(nonrest) - K(LV)) = 0.02 +/- 0.06 mm Hg/ml. In adults with cardiac disease, E(DT) provides an accurate estimate of LV operating stiffness and supports its application as a practical noninvasive index in the evaluation of diastolic function.

Aged↗

Caring in palliative nursing: competency or complacency?

Caring is an attribute of palliative nursing that is assumed to be fundamental. However, as the sophistication of palliative care increases, the liberal art of caring has become submerged under the weight of medical and pharmacological sciences. The nursing profession defends caring as the essence of its practice yet caring work in the palliative environment receives relatively little attention in research or in literature generally. Although it is accepted that nurses' caring work sometimes involves intimate and private aspects of patient care, the value and positive outcomes of caring should not remain hidden. Palliative nurses have special but tentative opportunities to prove the value of caring and define the complexity of caring work. This article argues that nurses need to reclaim the caring ethic and demonstrate its worth.

Empathy↗

Cardiac exercise hemodynamics late after partial left ventriculectomy.

BACKGROUND: Although some patients report favorable activity levels late after partial left ventriculectomy (PLV), their exercise physiology has not been well described. METHODS AND RESULTS: We performed upright bicycle hemodynamics in 10 patients (9 men) aged 56+/-12 years at 1.7 years after PLV. Ejection fraction was 25+/-4%. Patients biked 10+/-7 minutes. With exercise, the mean pulmonary arterial pressure rose from 36+/-12 to 52+/-10 mm Hg (P:=0.0003). The mean pulmonary capillary wedge pressure rose from 25+/-14 to 36+/-9 mm Hg (P:=0.0566), and the cardiac index rose from 2.2+/-0.5 to 3.8+/-1.6 L. min(-1). m(-2) (P:=0.0077). The mixed venous oxygenation with exercise declined from 44+/-9% to 24+/-17% (P:=0. 0220), and the pulmonary vascular resistance increased from 2.0+/-0. 9 to 2.3+/-1.1 Wood units (P:=0.5566). CONCLUSIONS: In late follow-up after PLV with exercise, the cardiac index is significantly augmented. However, there are further rises in pulmonary artery and pulmonary capillary wedge pressures, suggesting abnormal compliance, with marked decline in mixed venous oxygenation. Elucidating late physiology after PLV may help pave the way for future innovative heart failure surgeries.

Blood Gas Analysis↗

Technical efficiency and economies of diversification in health care.

In national health services, where there is a tendency towards a lack of resources and a continuous increase in demand, it is necessary to implement decisions that promote efficiency. In this paper we focus on potential diversification economies as a strategy to increase efficiency levels. We evaluate the change in efficiency in Catalan hospitals between 1987 and 1992, and analyse the presence of possible diversification economies in each hospital. We use Data Envelopment Analysis, which does not need information on either input or output prices. The results are that the majority of hospitals could increase their efficiency and reduce their costs by diversification to the output-mix offered. Potential productivity gains are between 29% and 46%.

Benchmarking↗

Oncology nurses' experience of dimethyl sulfoxide odor.

This article presents findings of an exploratory descriptive study on the effects of dimethyl sulfoxide (DMSO) odor in an oncology unit. The nursing staff, who had reported their concerns about the unpleasant odor emitted from patients undergoing peripheral stem cell transplantation, initiated the study. A literature review revealed some evidence of the possible ill effects on staff caring for patients having DMSO treatment, but many questions remain unanswered such as what staff experience in dealing with DMSO odor and whether nursing care is affected in any way? Data were collected through interviews with 22 oncology nurses who all had experienced direct and indirect exposure to DMSO odor. Of the 22 nurses interviewed, 20 reported that they found DMSO odor unpleasant and reported experiencing physical symptoms such as headaches and gastrointestinal reactions. The study also revealed a situation in which nurses described odor avoidance and distancing strategies that potentially compromised the nurse-patient relationship.

Cryoprotective Agents↗

The UK National External Quality Assessment Scheme in Blood Group Serology. Compatibility testing 1983-1984: the influence of variables in test procedures on detection of incomplete antibodies.

Error rates in exercises in compatibility testing varied between 3% and 36% over the six years 1979-1984. Evolution of serological procedures was continuous through this period but without clear evidence of improvement in performance of antibody detection although performance in the UK appears to be comparable with that elsewhere. Relationships have been established between a number of variables of reagents and techniques, and their performance. The influence of some variables is reasonably clear but there appear to be interactions between certain variables in their effects on performance, and interpretation is less straightforward. A test for agglutination of enzyme treated cells together with an antiglobulin test appears to be the most reliable combination for detection of incomplete antibodies in compatibility testing although one stage enzyme techniques are an inevitable compromise between reliability and convenience. Compatibility testing should not be considered in isolation from antibody screening in determining the optimum combination of tests for pretransfusion antibody detection.

Agglutination Tests↗

The UK National External Quality Assessment Scheme in Blood Group Serology. ABO and D grouping and antibody screening 1982-1983.

In seven surveys of blood grouping the overall rates of major error were 0.12% and 0.37% for uncomplicated ABO and D grouping respectively. Of 17 errors of ABO grouping, 13 were errors of transposition or interpretation and four were apparently technical. Of 52 errors of D grouping, 20 appeared to be errors of transposition or interpretation and 32 were apparently technical. Of the 32 technical errors of D grouping, 31 were D-negative grouped as Du (29) or D-positive (2) and most of these errors were due to misgrouping in the antiglobulin test. Causes of error in D grouping by antiglobulin test include anti-Bg and other contaminating immune antibodies, residual unabsorbed anti-A and the inherently high rate of false positive results obtained in the antiglobulin test. In view of the lack of benefit of Du testing to blood recipients or to pregnant women and of the possible adverse consequences of misgrouping D-negative patients as Du or D-positive, it is recommended that Du testing be abandoned in these groups of patients. The surveys of antibody screening demonstrated lack of standardisation and error rates similar to those previously reported in the UK for compatibility testing.

ABO Blood-Group System↗

Proficiency testing in immunohaematology in Ontario, Canada, and in the United Kingdom: a comparative study.

A comparative study of proficiency testing models in immunohaematology has been carried out between the United Kingdom National External Quality Assessment Scheme and the Laboratory Proficiency Testing Program of the Ontario Medical Association, using material supplied by both programmes to laboratories in the United Kingdom and Ontario. The results suggest that the general standard of performance in immunohaematology practice is similar in the two jurisdictions and that, where clear differences are seen, these reflect differences in technique or in educational emphasis.

Agglutination Tests↗

The UK national external quality assessment scheme in blood group serology. Compatibility testing 1981-1982: performance and practice.

The design of exercises of compatibility testing was modified in 1981 in order better to accommodate participants' serological practices. Ten reference laboratories were also enrolled in order to determine the 'correct' results for each exercise. In 1981-1982 3.5 to 36% of participants missed incompatibilities in exercises in which undiluted antibodies were issued and this did not represent an improvement over performance obtained in 1979-1980. Surveys were undertaken of antiglobulin test procedures and revealed that serological practices continue to change, old techniques are being modified, new techniques are being employed but standardization shows little overall improvement. Surveys of quality control procedures and of cross-match procedures for agglutination in albumin and for agglutination of enzyme treated cells show equal lack of standardization.

Blood Banks↗