PubMed Health⌕ Search

Biomedical subjects

D R Chettle

Publications and source records attributed to D R Chettle.

At least 19 recordsLinked to original sources

In vivo prompt gamma neutron activation analysis of cadmium in the kidney and liver.

An existing McMaster University in vivo prompt gamma neutron activation analysis system has been improved in order to reduce the cadmium detection limit in the kidney and liver. The detection limit for the kidney was found to be 1.7 mg, a greater than factor of 2 improvement over the previous results obtained at McMaster. The liver detection limit was determined to be 3.3 ppm. The corresponding skin dose for these measurements was only 0.5 mSv. The effect of kidney position on the detection limit also was examined. Figures of merit were calculated in order to compare the performance of the current system to others.

Cadmium↗

In vivo measurement of bone aluminium: recent developments.

A biomarker of aluminium accumulation in the human body can play a valuable role in determining health effects of chronic aluminium exposure, complementing other human and environmental monitoring data. In vivo neutron activation provides such a non-invasive biomarker. To date, the best in vivo neutron activation system used thermalised neutrons from a nuclear reactor at Brookhaven National Laboratory, which suffered only slightly from interference from other elements, primarily phosphorus, and from the disadvantage of restricted accessibility. At McMaster, we use a nuclear reaction on an accelerator to select neutron energy, which eliminates the interferences. Spectral decomposition analysis improved sensitivity. A new 4pi detection system also enhanced sensitivity. Together these improvements yield a minimum detection limit of 0.24 mgAl in a hand, slightly better than at Brookhaven and equivalent to "normal" levels. Further improvements should result from a new irradiation cavity and from using a higher proton current on the accelerator to shorten irradiation times. The system is now ready for pilot human studies.

Aluminum↗

Quantification of bone strontium levels in humans by in vivo x-ray fluorescence.

The need for in vivo bone strontium assessment arises because strontium may exert a number of effects on bone, which may be either beneficial or toxic. Measurements discussed here are noninvasive, no sample is taken, nor is there discomfort to patients. The developed source excited x-ray fluorescence system employs a 109Cd source to excite the strontium K x rays, with the source and detector in approximately 90 degree geometry relative to the sample position. The factors affecting the accuracy and minimal detectable limit for bone strontium in vivo measurements are discussed. A system calibration revealed a minimum detectible limit of approximately 0.25 mg Sr/g Ca, which is sufficient for the monitoring of strontium levels in healthy subjects and patients with elevated bone strontium concentrations. Preliminary in vivo measurements in ten healthy subjects at two bone sites (phalanx and tibia) indicated that this system can be applied for cumulative bone strontium estimation while delivering a low effective dose of 80 nSv during the measurement time. Future work will involve attempts to enhance system precision with alternative fluorescing sources and further optimization of the detection system.

Bone and Bones↗

An investigation of the toxicity of gadolinium based MRI contrast agents using neutron activation analysis.

The toxicity of gadolinium (Gd) based MRI contrast agents, is based upon the amount of Gd that dissociates from its chelate and deposits in tissues. In this study, the toxicities of two contrast agents were tested using different injection strategies in two animal models. Following a bolus injection of 0.2 mmol/kg of Gd-DTPA in a pilot study with a single canine, Gd levels were as high as 2.05 +/- 0.17 ppm and 0.47 +/- 0.11 ppm 2 weeks post injection in the kidney and liver tissues, respectively. To evaluate the role that the injection strategy plays in toxicity, 0.8 mmol/kg of Gd-(HP-DO3A) was injected into rats, in a second study, via bolus and constant infusion techniques. Gd was only detected in the kidney in the bolus injected rats but in the lung as well in the constant infusion injected rats. Concentrations detected in the kidney for both strategies, were comparable within error: 1.37 +/- 0.46 ppm for the bolus and 1.24 +/- 0.39 ppm for the bolus/constant infusion strategy and 0.16 +/- 0.14 ppm in the lung for the constant infusion technique. The contrast infusion technique does not appear to present an increased risk of toxicity over the bolus technique except perhaps to a small degree in the lung.

Animals↗

Ultrasound measurements of overlying soft tissue thickness at four skeletal sites suitable for in vivo x-ray fluorescence.

Due to signal attenuation in overlying soft tissue, development of x-ray fluorescence systems to measure low atomic number elements, such as strontium, in human bone required a search for a skeletal site with thin overlying tissue. This paper reports ultrasound measurements of overlying tissue on 10 subjects, at four anatomical sites. The average tissue thickness at the finger was (2.9+/-0.7) mm. The average tissue thicknesses were (3.6+/-0.7) mm, (4.8+/-2.0) mm, and (8.4+/-1.7) mm at forehead, tibia and heel, respectively. Additionally, both parametric and nonparametric approaches to the relationship between body mass index (BMI) and tissue thickness suggest that there is a significant linear correlation between the subject's BMI and overlying tissue at the finger and heel bone. These correlations might be used as a criterion to perform XRF measurements, however a larger data set is required to address these correlations more clearly.

Adult↗

An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones.

Manganese (Mn) is an essential nutrient for growth and development. Unfortunately, overexposure can lead to neurological damage, which is manifested as a movement disorder marked by tremors. Preclinical symptoms have been found in populations occupationally exposed to the element, and it is suggested that in late stages of the disorder, removing the Mn exposure will not prevent symptoms from progressing. Hence, it is desirable to have a means of monitoring Mn body burden. In vivo neutron activation analysis (IVNAA) is a technique which allows the concentration of some elements to be determined within sites of the body without invasive procedures. Data in the literature suggests that the Mn concentration in bone is greater than other tissues, and that it may be a long term storage site following exposure. Therefore, using the McMaster KN-accelerator to produce neutrons through the 7Li(p,n)7Be reaction, the feasibility of IVNAA for measuring Mn levels in the human hand bone was investigated. Mn is activated through the 55Mn(n,gamma)56Mn reaction, and the 847 keV gamma rays emitted when 56Mn decays are measured outside the body using NaI(Tl) detectors. An optimal incident proton energy of 2.00 MeV was determined from indium foil and microdosimetry measurements. Hand phantom data suggest a minimum detectable limit of approximately 1.8 ppm could be achieved with a reasonably low dose of 50 mSv to the hand (normal manganese levels in the human hand are approximately 1 ppm). It is recommended the technique be developed further to make human in vivo measurements.

Bone and Bones↗

Normalisation with coherent scatter signal: improvements in the calibration procedure of the 57Co-based in vivo XRF bone-Pb measurement.

The feasibility of a normalised calibration variable to account for interpatient variability for in vivo 57Co XRF (X-ray fluorescence) finger bone-lead measurements was assessed. Normalising the lead X-ray intensities to the coherent scatter signal was investigated by experiment and Monte Carlo simulation. The X-ray to coherent ratios for a fixed lead concentration were within 5-10% of the mean, within uncertainty, over a physiologically relevant range of finger bone sizes and overlying tissue thicknesses. This is an acceptable level of variation to introduce, as it is less than the uncertainty of a typical in vivo measurement. Normalisation has several advantages compared with the current method of correcting for interpatient variation, as it eliminates the need for transporting extensive equipment to on-site measurements, reduces the subject dose by a factor of two, and increases the objectivity of the bone-Pb assessment.

Bone and Bones↗

Longitudinal changes in bone lead concentration: implications for modelling of human bone lead metabolism.

In this study, 539 occupationally exposed subjects received in vivo bone lead measurements using 109Cd excited K X-ray fluorescence (109Cd K XRF). Of these subjects, 327 had previously been measured five years earlier. Measurements were made from both tibia and calcaneus samples, taken to reflect cortical and trabecular bone, respectively. Changes in tibia lead concentration related negatively to initial tibia lead concentration and positively to both lead exposure between the measurement dates and initial calcaneus lead concentration. This finding confirmed and strengthened the interpretation of an earlier study involving fewer subjects. With the larger data set it was possible to examine subgroups of subjects. This showed that people aged less than 40 years had a shorter half-life for the release of lead from the tibia (4.9, 95% CI 3.6-7.8 years) than did those older than 40 (13.8, 95% CI 9.7-23.8 years). Similarly, less intensely exposed subjects (lifetime average blood lead < or = 25 micrograms dL-1) had a shorter tibia lead half-life (6.2, 95% CI 4.7-9.0 years) than those with a lifetime average blood lead > 25 micrograms dL-1 (14.7, 95% CI 9.7-29.9 years). Age and measures of lead exposure were strongly correlated; nevertheless, age matched subgroups with high and low intensity exposures showed clearance rates that were significantly different at the 10% level, with the lower exposure intensity again being associated with the faster clearance. These findings imply that current models of human lead metabolism should be examined with a view to adjusting them to account for kinetic rates varying with age and probably also with exposure level.

Adult↗

Study of the relationships between bone lead levels and its variation with time and the cumulative blood lead index, in a repeated bone lead survey.

The study aims were to: (i) investigate long term human lead metabolism by measuring the change of lead concentration in the tibia and calcaneus; and (ii) assess whether improved industrial hygiene was resulting in a slow accumulation of lead in an exposed workforce. 109Cd excited K X-ray fluorescence was used to measure tibia lead and calcaneus lead concentrations in 101 workers in a secondary lead smelter. 51 subjects had had similar bone lead measurements 5 years previously. Most of the other subjects had been hired since the first survey. Measurements of whole blood lead were available for the large majority of subjects. Tibia lead concentrations fell significantly (p<0.001) in the 51 subjects with repeated bone lead measurements, from a mean of 39 microg Pb (g bone mineral)(-1) to 33 microg Pb (g bone mineral)(-1). The change correlated negatively with the initial tibia lead concentration, producing an estimate for an overall half-life of 15 years, with a 95% confidence interval of 9 to 55 years. Adding continuing lead exposure and recirculation of bone lead stores to the regression models produced half-life estimates of 12 and 9 years, respectively, for release of lead from the tibia. The repeat subjects showed no net change in calcaneus lead (64 microg Pb (g bone mineral)(-1) initially, 65 microg Pb (g bone mineral)(-1) 5 years later). Subjects not measured previously had average lead concentrations of 15 microg Pb (g bone mincral)(-1) in the tibia and 13 microg Pb (g bone mineral)(-1) in the calcaneus. The rate of clearance of lead from the tibia (9 to 15 years) is towards the more rapid end of previous estimates. The lack of a significant fall in the calcaneus lead was surprising. Attempts should be made to repeat this observation. If confirmed, it would have implications for models of lead metabolism. The relatively low lead concentrations in the non-repeat subjects are reassuring. However, observation after a longer period of employment would be desirable.

Adult↗

Gamma ray nuclear resonance absorption: an alternative method for in vivo body composition studies.

We have evaluated gamma ray nuclear resonance absorption (gamma-NRA) on nitrogen, a mature technology proposed and developed by Soreq NRC for detecting explosives, as an alternative to neutron activation for in vivo assaying of body nitrogen. The principles of the gamma-NRA method are outlined, and a test facility constructed at McMaster University's Accelerator Laboratory is described. The results of a feasibility study recently performed there on phantoms and animal tissue are presented and discussed. gamma-NRA is a full imaging technique that essentially constitutes element-specific absorptiometry--i.e., it can generate projections of the mass distribution for a specific element, along with a conventional radiograph of the patient. From the transmission profile of an individual scanned by 9.17 MeV gamma rays, local or whole body nitrogen content can be determined via the resonant attenuation undergone when the beam encounters regions of nitrogen concentration. The advantages of gamma-NRA over neutron activation are (a) radiation doses delivered to the body are at least one order of magnitude lower, thus allowing repeated measurements on individual patients and also rendering the method ethically acceptable for application to children; (b) gamma-NRA is inherently free from uncertainties related to nonuniform distributions of the element in question within the body; (c) it is applicable to patients of varying size and shape; and (d) it yields both nitrogen images and conventional radiographic images of the body.

Animals↗

109Cd K x ray fluorescence measurements of tibial lead content in young adults exposed to lead in early childhood.

OBJECTIVES: Tibia lead measurements were performed in a population of 19-29 year old people who had been highly exposed to lead in childhood to find whether lead had persisted in the bone matrix until adulthood. METHODS: (109)Cd K x ray fluorescence was used to measure the tibia lead concentrations of 262 exposed subjects and 268 age and sex matched controls. Questionnaire data allowed a years of residence index to be calculated for exposed subjects. A cumulative blood lead index was calculated from the time weighted integration of available data of blood lead. RESULTS: The mean (SEM) difference between exposed and control men was 4.51 (0.35) micrograms Pb/g bone mineral, and between exposed and control women was 3.94 (0. 61) micrograms Pb/g bone mineral. Grouped mean bone lead concentrations of exposed subjects were predicted best by age. When exposed and control subjects' data were combined, grouped mean bone lead concentrations were predicted best by cumulative blood lead index. The years of residence index was neither a good predictor of bone lead concentrations for exposed subjects nor for exposed and control subjects combined. Finally, exposed subjects had increased current blood lead concentrations that correlated significantly with bone lead values. CONCLUSION: Bone lead concentrations of exposed subjects were significantly increased compared with those of control subjects. Lead from exposure in early childhood had persisted in the bone matrix until adulthood. Exposed subjects had increased blood lead concentrations compared with controls. Some of this exposure could be related to ongoing exposure. However, some of the increase in blood lead concentration in adult exposed subjects seemed to be a result of endogenous exposure from increased bone lead stores. The endogenous exposure relation found for men was consistent with reported data, but the relation found for women was significantly lower. Further research is needed to find whether the observed differences are due to sex, or pregnancy and lactation.

Adult↗

The O'Flaherty model of lead kinetics: an evaluation using data from a lead smelter population.

The O'Flaherty model of lead kinetics is a physiologically based computer model of lead disposition in humans. The model is based on an age-dependent approach to human growth, with particular attention devoted to bone metabolism. As such, model output is well suited for comparison with noninvasive bone lead measurements made via X-ray fluorescence. A subset of workers from a lead smelter population were selected for an initial evaluation of the O'Flaherty model. Detailed blood lead records were used to define input. Simulated bone lead and blood lead output were compared with observation, enabling a refinement of model parameters. A revised version of the O'Flaherty model was then evaluated for the smelter population as a whole. Previously observed trends for the accumulation of lead in cortical bone and the release of lead from bone stores were well explained by the revised model. Model predictions for the accumulation of lead in trabecular bone were not in accord with observed levels in the calcaneus. Model results from the smelter population are consistent with the hypothesis that a polymorphism in the delta-aminolevulinate dehydratase enzyme modifies the kinetics of lead in humans. Further refinements are suggested, which may enhance the ability of the model to explain the underlying relationships between lead exposure and the distribution of lead in the body.

Aging↗

Factors affecting in vivo measurement precision and accuracy of 109Cd K x-ray fluorescence measurements.

109Cd K x-ray fluorescence (XRF) measurement systems from two research centres were used to measure tibia lead content in a population (n = 530) of young adults. The group mean bone lead contents (+/-SEM) determined by McMaster University (n = 214) and the University of Maryland (n = 316) were 2.80 +/- 0.51 and 2.33 +/- 0.50 microg Pb/(g bone mineral) respectively. The mean difference of 0.47 +/- 0.71 microg Pb/(g bone mineral) was not significant. There was no evidence of a systematic difference between measurements from the two systems. Measurement uncertainties for the young adults were poorer overall than uncertainties for a population of occupationally exposed men. This was because obese subjects and women were included in the study. Regressions of precision against body mass index (BMI, defined as weight/height2) determined that uncertainties increased with BMI and were poorer for women than men. Measurement uncertainties (1sigma) were >8 microg Pb/(g bone mineral) for women with a BMI > 0.004 kg cm(-2). Poor-precision data affected population estimates of bone lead content; an inverse correlation was found between precision and bone lead content. A small number (0.4%) of individual measurements with poor uncertainties were inaccurate to within the precision. It is suggested that obese subjects, whose BMI > 0.004 kg cm(-2), should be excluded from 109Cd K XRF studies, as the measurement provides limited information and may be inaccurate.

Adult↗

Effect of the delta-aminolevulinate dehydratase polymorphism on the accumulation of lead in bone and blood in lead smelter workers.

Lead inhibition of the zinc metalloenzyme delta-aminolevulinate dehydratase (ALAD) is one of the most sensitive indicators of blood lead levels. ALAD is polymorphic, with about 20% of Caucasians expressing the rarer ALAD2 allele. Previous studies indicated that this polymorphism may be a genetic factor in lead transport, metabolism, and/or distribution. Whole blood lead, serum lead, and ALAD genotype were determined for 381 lead smelter workers, including 70 workers expressing the ALAD2 allele, whose blood lead elevations were observed for more than 20 years of employment. The same employees demonstrated higher serum lead levels. Using a cumulative blood lead index (CBLI) for each worker, based on individual blood lead histories, and in vivo X-ray fluorescence measurements of bone lead to estimate total lead body burden, the slopes of linear relations of bone lead to CBLI were greater for workers homoallelic for ALAD1, indicating more efficient uptake of lead from blood into bone. This effect was most significant in calcaneus bone and for workers hired since 1977 [ALAD1-1: 0.0528 +/- 0.0028 and ALAD1-2 or 2-2: 0.0355 +/- 0.0031 (P < 0.001)]. Decreased transfer of blood lead into bone in individuals expressing the ALAD2 allele contrasted with increased blood lead. Thus the ALAD genotype affected lead metabolism and potentially modified lead delivery to target organs including the brain; however, the ALAD genotype did not significantly affect the net accumulation of lead in bone.

Amino Acid Sequence↗

Is there any association between the presence of bone disease and cumulative exposure to lead?

There is evidence from cell culture experiments, animal studies, and from measurements in humans that lead may exert detrimental effects on bone mineral metabolism. In order to explore a possible association between lead and bone disease, both cortical and trabecular bone lead content as well as serum lead concentration was measured in 117 patients who attended a metabolic bone disease clinic (n = 92) or were undergoing dialysis for renal failure (n = 25). Cortical bone lead content was higher in patients suffering from Paget's disease than it was in controls, patients with osteoporosis, and patients on dialysis. Trabecular bone lead content was lowest in patients with Paget's disease or osteitis fibrosa. There was no association between bone lead content and serum alkaline phosphatase concentration in patients suffering from osteoporosis. No statistically significant differences in serum lead concentrations were found between groups. Our results do not distinguish between the two possibilities that increased bone turnover due to Paget's disease releases lead from trabecular bone which is then available for deposition into cortical bone or the alternative possibility that an increased lead content in cortical bone may cause increased turnover with release of lead from trabecular bone.

Aged↗

Monte Carlo simulation of source-excited in vivo x-ray fluorescence measurements of heavy metals.

This paper reports on the Monte Carlo simulation of in vivo x-ray fluorescence (XRF) measurements. Our model is an improvement on previously reported simulations in that it relies on a theoretical basis for modelling Compton momentum broadening as well as detector efficiency. Furthermore, this model is an accurate simulation of experimentally detected spectra when comparisons are made in absolute counts; preceding models have generally only achieved agreement with spectra normalized to unit area. Our code is sufficiently flexible to be applied to the investigation of numerous source-excited in vivo XRF systems. Thus far the simulation has been applied to the modelling of two different systems. The first application was the investigation of various aspects of a new in vivo XRF system, the measurement of uranium in bone with 57Co in a backscatter (approximately 180 degrees) geometry. The Monte Carlo simulation was critical in assessing the potential of applying XRF to the measurement of uranium in bone. Currently the Monte Carlo code is being used to evaluate a potential means of simplifying an established in vivo XRF system, the measurement of lead in bone with 57Co in a 90 degrees geometry. The results from these simulations may demonstrate that calibration procedures can be significantly simplified and subject dose may be reduced. As well as providing an excellent tool for optimizing designs of new systems and improving existing techniques, this model can be used in the investigation of the dosimetry of various XRF systems. Our simulation allows a detailed understanding of the numerous processes involved when heavy metal concentrations are measured in vivo with XRF.

Biophysical Phenomena↗

Neurotoxicity in young adults 20 years after childhood exposure to lead: the Bunker Hill experience.

OBJECTIVES: An epidemiological study of young adults was conducted to determine whether environmental exposure to lead during childhood was associated with current adverse neurobehavioural effects. METHODS: The exposed group consisted of 281 young adults who had been exposed environmentally to lead as children and the unexposed referent group consisted of 287 age and sex frequency matched subjects. Information on demographics, past and current health, and past exposures to neurotoxicants, and responses to the Swedish Q16 questionnaire were collected by interview. Standard neurobehavioural and neurophysiological tests were administered by computer or trained technicians. K x ray fluorescence was used to estimate tibial bone lead concentrations among the exposed and unexposed groups. Associations were examined between the exposed group and referents and tibial bone lead concentration and the neurobehavioural and neurophysiological outcomes of interest. RESULTS: Among the measures of peripheral nerve function, after controlling for confounders, sural sensory nerve evoked response amplitude, peroneal motor nerve compound motor action potential amplitude, vibrotactile thresholds of fingers and toes, and standing steadiness were significantly associated with exposure group. Among the neurobehavioural tests, hand-eye coordination, simple reaction time latency, trails B latency, symbol digit latency, serial digit, and learning error score were also significantly associated with exposure group after controlling for confounders. Exposed subjects had significantly more neuropsychiatric symptoms than the referents. Associations between tibial bone lead concentration and scores for vocabulary, vibrotactile thresholds of the fingers, and vibrotactile thresholds of the toes approached significance. CONCLUSIONS: Significant adverse central and peripheral neurological effects were found in a group of young adults 20 years after childhood environmental exposure to lead when compared with non-exposed controls. The absence of a significant association between neurological outcomes and tibial bone lead concentration, and the presence of significant associations between neurological outcomes and exposure group may be due to either the magnitude of measurement uncertainty in K x ray films relative to the actual tibial bone lead concentration in these young non-occupationally exposed subjects, or uncontrolled confounding of the exposure group.

Adult↗