PubMed Health⌕ Search

Biomedical subjects

D R Dudeja

Publications and source records attributed to D R Dudeja.

2 recordsLinked to original sources

Functional vision and corneal changes after laser in situ keratomileusis determined by contrast sensitivity, glare testing, and corneal topography.

PURPOSE: To demonstrate the functional vision and corneal changes following laser in situ keratomileusis (LASIK) determined by contrast sensitivity, glare testing, and corneal topography. SETTING: University of Texas Medical School, Houston, Texas, USA. METHODS: Seven patients ranging in age from 20 to 61 years who had bilateral LASIK were evaluated preoperatively and 1 day, 1 week, and 1 and 6 months postoperatively. Visual acuity, using letters on the Baylor Visual Acuity Testor (BVAT) at 98% (standard acuity) and 13% contrast, and the contrast threshold were determined at 3 light levels (darkness, medium brightness acuity testor [BAT], high BAT). Pupil sizes were measured at each level, and corneal topography was performed at each visit. RESULTS: The greatest changes were found 1 day postoperatively: The contrast threshold worsened by a mean of 0.6 lines +/- 1.0 (SD) (P = .05) in darkness, 0.4 +/- 0.7 lines (P = .05) at medium BAT, and 0.8 +/- 0.7 lines (P = .002) at high BAT. The 98% contrast acuity decreased a mean of 1.4 +/- 1.6 lines (P = .01) in darkness, 1.0 +/- 2.0 lines (P = .09) at medium BAT, and 0.8 +/- 2.3 lines (P = .22) at high BAT. The 13% contrast acuity decreased a mean of 2.2 +/- 2.6 lines (P = .01) in darkness, 1.3 +/- 1.9 lines (P = .02) at medium BAT, and 1.4 +/- 2.5 lines (P = .07) at high BAT. The predicted corneal acuity (PCA) obtained from corneal topography decreased by a mean of 3.3 +/- 3.1 lines (P = .002), and the asphericity (Q-value) increased by an average of +0.35 +/- 0.67 (P = .07). All values returned to the preoperative levels by 1 week except PCA, asphericity, visual acuity at 13%, and contrast threshold in darkness, which improved slightly but had not returned to baseline by 6 months. The 98% contrast acuity at medium BAT improved by 0.2 +/- 1.0 lines (P = .34) and 0.3 +/- 0.8 lines (P = .16) at high BAT at 1 month. The 98% contrast acuity values remained 0.3 lines over baseline through 6 months. Corneal topography showed that all corneas became oblate after LASIK to a mean Q-value of +0.47 +/- 0.40 (P = .0001) and PCA was decreased by 1.6 +/- 1.1 lines (P = .0002) at 6 months. CONCLUSIONS: Functional vision changes do occur after LASIK. The optical quality of the cornea is reduced and the asphericity becomes oblate. Changes in functional vision worsen as the target contrast diminishes and the pupil size increases. These findings indicate that the oblate shape of the cornea following LASIK is the predominant factor in the functional vision decrease.

Adult↗

Evaluating and reporting astigmatism for individual and aggregate data.

PURPOSE: To demonstrate the proper method for evaluating and reporting astigmatism for individual and aggregate data. SETTING: University of Texas Medical School and Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. METHODS: The surgically induced refractive change (SIRC) was determined for three data sets of patients who have had keratorefractive (photorefractive keratectomy) or cataract surgery. To make changes in refraction comparable, vertex distances for the refractions and keratometric index of refraction were considered. Doubledangle plots and single-angle plots were then used to display the data. Polar values (cylinder and axis) were converted to a Cartesian (x and y) coordinate system to determine the mean value of the induced astigmatism for each data set. RESULTS: Doubled-angle plots clearly demonstrated the trends of induced astigmatism for each data set, and the mean value for induced astigmatism agreed exactly with the intuitive appearance of the plot. CONCLUSIONS: Converting astigmatism data to a Cartesian coordinate system allowed the correct computation of descriptive statistics such as mean values, standard deviations, and correlation coefficients. Using doubled-angle plots to display the data provides the investigator with the best method of recognizing trends in the data.

Astigmatism↗