Publications and source records attributed to D R Hose.

14 recordsLinked to original sources

Development of an accurate three-dimensional finite element knee model.

This paper presents the development of a detailed articulating three-dimensional finite-element model of the human knee, derived from MRI scan images. The model utilises precise material models and many contact interfaces in order to produce a realistic kinematic response. The behaviour of the model was examined within two fields of biomechanical simulations: general life and car-crash. These simulations were performed with the non-linear explicit dynamic code PAM-SAFE trade mark. The knee model produced results that compared favourably with existing literature. Such a model (together with other joint models that could be constructed using the same techniques) would be a valuable tool for examining new designs of prosthesis and mechanisms of injury.

Accidents, Traffic↗

Modelled current distribution in cervical squamous tissue.

The electrical properties of cervical squamous epithelium have been modelled in the frequency range 100 Hz to 10 MHz. The hierarchical modelling process comprises a cellular level stage, which includes detailed models of cells typical of different depths within the epithelium and a tissue model, which utilizes electrical properties obtained from the cellular models. The fit between the modelled and measured impedance spectra and the distribution of current with depth depends on the macroscopic model structure. Both the properties of the basement membrane and the presence of a surface mucus layer are shown to have a significant effect. The best fit with measured data is obtained when a 10 microm thick, high-conductivity surface layer is included in the tissue model.

Algorithms↗

Resistivity changes in conductive silicone sheets under stretching.

This paper reports a preliminary finding associated with an investigation of how tissues respond to mechanical stress. The stress distribution within the tissue may be the result of normal function, for example, joint forces, or it may result from interventions such as tissue suturing during or after surgery. We sought to combine electrical and mechanical computational models in order to better understand the interaction between the two. For example, if mechanical stress is applied to tissue this may change the cell arrangements within the tissue matrix and hence change the electrical properties. If this interaction could be determined, then it should be possible to use electrical impedance tomography measurements to identify stress patterns in tissues. Measurements of resistivity changes have been made in conductive silicone rubber sheets when subject to a uniaxial stress of up to 10%. Relatively large changes in resistivity are produced (up to 200%). These changes are far larger than those predicted arising from topological changes alone. It is suggested that under stress the conductive islands of carbon within the silicone rubber sheet undergo a reversible disassociation from their neighbours and that the material's electrical properties change under load. If similar stress-resistivity relationships occur within biological materials it may be possible to recover the stress fields within tissues from transfer impedance measurements and thereby predict if actions such as inappropriate suture tension will compromise tissue viability.

Algorithms↗

Computer model analysis of the Swanson and Sutter metacarpophalangeal joint implants.

A representative model which mimics the behaviour of Silastic finger metacarpophalangeal joint implants was constructed using a finite element software package. The modelled implants were moved through a range of flexion, lateral deviation and a combination of both. Pistoning of both implants stems occurred within the modelled medullary cavities. For equivalent flexion angles, the Sutter implant produced a higher stress field than the Swanson implant, and the field was positioned at the central hinge mechanism. In both implants, lateral deviation increased the internal stress concentrations more than when pure flexion was applied. Overall the Swanson style of implant had lower stress magnitudes than the Sutter implant, and it is predicted that the Sutter implant will be more likely to fail than the Swanson. The failure mode for the Sutter implant would be at the central hinge region. The Swanson implant is likely to fail at the central hinge-stem interface regions.

Computer Simulation↗

A goniometric glove for clinical hand assessment. Construction, calibration and validation.

The construction of a goniometric glove is described. Each of the sensors in the glove was calibrated over a custom built metal hand using blocks of known angles as angular references. The digital data output from each sensor of the glove were converted into angular displacements at each joint. The glove was validated for consistency of measurement and accuracy over a custom built metal jig and in the human hand. The accuracy of the glove was found to be within the limits of traditional goniometry. It is proposed that goniometric gloves could be useful in the assessment of hand function.

Calibration↗

An inexpensive sensor for measuring surface geometry.

A technique to measure surface geometry using a conductive ink sensor is described. In the human system distorted cylinders are common, and geometry can be reconstructed from local measures of curvature. An algorithm is presented to reconstruct the shape of a surface from a series of curvature measurements. The Abrams Gentile Entertainment patented bend sensor was evaluated as a curvature transducer. The sensor was tested at the extremes of the likely measurement range, from curvatures below 0.01 mm(-1) up to a curvature of 0.1 mm(-1). The upper curvature limit proved beyond the design specification of the sensor. The technique was applied at the lower curvature range to reconstruct one quadrant of the chest of a volunteer and record breathing movement. The bend sensor is inexpensive and can be applied to obtain an approximate reconstruction of surface geometry in the human system.

Adult↗

An impact analysis of a flexible bat using an iterative solver.

Although technology has now infiltrated and prompted evolution in most mass participation sports, the advances in bat technology in such sports as baseball and cricket have been relatively minor. In this study, we used a simple finite element modelling approach to try to shed new light upon the underlying mechanics of the bat-ball impact, with a view to the future optimization of bat design. The analysis of a flexible bat showed that the point of impact that produced the maximum post-impact ball velocity was a function of the bat's vibrational properties and was not necessarily at the centre of percussion. The details of the analysis agreed well with traditional Hertzian impact theory, and broadly with empirical data. An inspection of the relative modal contributions to the deformations during impact also showed that the position of the node of the first flexure mode was important. In conclusion, considerable importance should be attached to the bat's vibrational properties in future design and analysis.

Baseball↗

Anatomical and physiological models for surgical simulation.

A considerable amount of effort has been aimed towards developing real-time deformable objects for surgical simulation, but very little work has been aimed towards including physiology within the soft tissue models. A simulator that links the structural and functional aspects of the human body would allow the user to develop a better understanding of the intrinsic link between anatomy and physiology. This positional paper discusses the challenges facing the creation of and the development of an integrated physiological and anatomical soft tissue model for use in surgical simulators. It explores the artificial dichotomy between anatomy and physiology and the issues it raises, by considering a suturing simulator capable of modelling ischaemia.

Animals↗

In-situ simulation of one-piece metacarpophalangeal joint implants using finite element analysis.

Generally, reconstruction of the rheumatoid metacarpophalangeal (MCP) joint is achieved by means of implantation of a hinged silastic prosthesis. Whereas these implants restore some degree of mobility to the joint, they are prone to failure after a relatively short life-span, and little is known about their dynamical behaviour within the joint. In this study, the Swanson and Sutter designs of MCP implant were examined in an idealized joint environment by means of two-dimensional finite element analysis. The purpose was to assess how the differing geometry affected their behaviour as replacement joints, and whether they were inherently prone to abrasion and high stress concentrations during flexion. The results revealed the changing points of contact between the implant and the bone ends, and clearly showed the implant stems 'pistoning' in the intramedullary canals. This was found to be an effective way to provide preliminary information on the dynamic behaviour of an implant in a simulated joint. This would facilitate further optimization of design in advance of fabrication.

Computer Simulation↗

The use of enzyme activated milk for in vitro simulation of prosthetic valve thrombosis.

BACKGROUND AND AIM OF THE STUDY: Thrombosis remains a serious risk for patients with artificial heart valves and may be attributed in part to adverse blood flow patterns. Although the final assessment of a valve must follow years of clinical experience, in vitro flow analyses give valuable information prior to implantation. Laser Doppler velocimetry and computational fluid dynamics enable quantitative flow analyses to be made in vitro. Whilst these techniques highlight features such as areas of stasis, turbulence and high shear which may predispose to thrombus formation, the complex and time varying nature of the flow through valves makes it difficult to predict accurately potential sites of thrombus deposition and accumulation. METHODS: A technique is described which uses enzyme activated milk as a coagulable blood analogue to indicate flow related clotting. Milk flowing past a test valve or object was activated to clot downstream of the test piece after a certain time period. Milk clot was deposited clot at sites determined by the local flow disturbances. Milk clotting patterns produced on and around standard objects were compared with the transient flow patterns predicted around identical configurations to test the validity of computational flow analyses for predicting flow disturbances leading to clotting. Milk clots on valves were compared with examples of thrombus found on explanted valves of the same design. RESULTS: The sites of deposition were consistent with the predicted flow patterns around the two configurations of flow obstruction studied. Milk clotting patterns on valves corresponded with the early stages of thrombus on explanted valves of the same design. CONCLUSIONS: Whilst a coagulable milk mixture may be used to evaluate the risk of flow induced clot adherence, care must be taken when extrapolating to the clinical situation as other factors such as material properties, blood chemistry and concomitant disease must also be considered.

Animals↗

In vitro heart valve testing: steady versus pulsatile flow.

The design of artificial heart valves has traditionally been based on the development of a prototype device which was then subjected to extensive laboratory testing in order to confirm its suitability for clinical use. In the past the in vitro assessment of a valve's performance was based principally on the measurement of parameters such as pressure difference, regurgitation and, more recently, energy losses. Such measurements can be defined as being at the 'macro' level and rarely show any clinically significant differences amongst currently available prostheses. The analytical approach to flow through heart valves has previously been hampered by difficulties experienced in solving the relevant equations of flow particularly in the case of pulsatile conditions. Computational techniques are now available which enable appropriate solutions to be obtained for these problems and consequently provide an opportunity for detailed examination of the 'micro' level of flow disturbances exhibited by the different valves. This present preliminary study is designed to illustrate the use of such an analytical approach to the flow through prosthetic valves. A single topic has been selected for this purpose which is the comparative value of steady versus pulsatile flow testing. A bileaflet valve was chosen for the analysis and a mathematical model of this valve in the aortic position of the Sheffield Pulse Duplicator was created. The theoretical analysis was carried out using a commercially available Computational Fluid Dynamics package, namely, FIDAP, on a SUN MICROSYSTEMS 10-30 workstation.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity↗

Development of an ex vivo model to investigate the effects of altered haemodynamics on human bypass grafts.

The insertion of vein grafts into the arterial circulation may contribute to vessel wall thickening and accelerated atherosclerosis, a common feature of late vein graft failure. We aimed to develop a model suitable for investigation of the effects of altered haemodynamics on human saphenous vein following its implantation into the arterial circulation. Segments of human saphenous vein obtained from patients undergoing coronary artery bypass surgery were sutured at each end to PTFE and placed into a flow system. Pressure and flow rates to stimulate the arterial and venous systems were achieved. A theoretical model of the flow chamber was created and computational fluid dynamics software (FLOTRAN, Swanson Analysis Systems) was used to determine the flow profile within the model. In summary, a flow model has been developed to investigate the effect of altered haemodynamics on the molecular and pathological changes that occur in vein grafts incorporated into the arterial circulation.

Blood Flow Velocity↗

The origin and significance of secondary flows in the aortic arch.

This paper comprises a study of the secondary flow patterns that can develop in the human aortic arch. Clinical evidence of these secondary flows has been obtained by Kilner et al. using magnetic resonance velocity mapping techniques. Some of their results are presented for comparison in this paper. Four difference parametric models of the aortic arch have been analysed using computational fluid dynamic techniques. Both steady and transient flow conditions have been considered and two different commercially available software packages were used, namely FIDAP and FLOTRAN. A satisfactory comparison of the theoretical analysis with the results, both in vivo and in vitro, obtained by Kilner et al. for their out-of-plane inlet model was found. The theoretical analysis can now be extended to analyse the effect of different configurations and orientations of artificial aortic valves on the resulting aortic arch flow patterns.

Aorta, Thoracic↗

An examination of one-piece metacarpophalangeal joint implants using finite element analysis.

Reconstruction of the rheumatoid metacarpophalangeal (MCP) joint is generally achieved by means of implantation of a hinged silastic prosthesis. These implants reduce the pain in joint and restore some degree of mobility. However, they are prone to failure after a relatively short life-span. In this study, two popular designs of MCP implant, the Swanson and the Sutter, were compared by means of three-dimensional finite element analysis. The aim was to examine how the differing geometry effected their relative stiffness as replacement joints, and whether they were inherently prone to high stress concentrations during flexion. Although the Swanson design implant exhibited relatively greater resistance to flexion, both designs showed regions of high stress concentration and it was noted that neither was without its limitations. The use of the finite element technique was found to be an excellent way to provide preliminary design evaluation information, allowing further evolution before clinical trials.

Arthritis, Rheumatoid↗