PubMed Health⌕ Search

Biomedical subjects

D R Neumann

Publications and source records attributed to D R Neumann.

At least 19 recordsLinked to original sources

Lymphoscintigraphy using (99m)Tc filtered sulfur colloid in chylothorax: a case report.

OBJECTIVE: A 66-y-old man was diagnosed with esophageal carcinoma and underwent a right thoracotomy and esophagectomy. Postoperatively, a recurring right pleural effusion developed. Because an attempt at lymphangiography failed, lymphoscintigraphy was suggested. Because of the inability to obtain radiolabeled albumin, dextran, or nanocolloid, we used filtered sulfur colloid. (0.1 um). The study confirmed the diagnosis of chylothorax.

Aged↗

Sestamibi/iodine subtraction single photon emission computed tomography in reoperative secondary hyperparathyroidism.

BACKGROUND: Sestamibi/iodine subtraction single photon emission computed tomography (SPECT) has been used successfully for the preoperative localization of adenomatous and hyperplastic parathyroid tissue in primary hyperparathyroidism, but the clinical usefulness of this technique in secondary hyperparathyroidism remains uncertain. The purpose of this study was to evaluate parathyroid localization that uses sestamibi/iodine subtraction SPECT in patients with secondary hyperparathyroidism before reoperative parathyroid surgery. METHODS: Fourteen consecutive patients with chronic renal failure and secondary hyperparathyroidism who had previously undergone total parathyroidectomy combined with parathyroid autotransplantation in a sternocleidomastoid muscle were studied. Before reoperation, each patient received 400 microCi of sodium iodide I 123 orally and 20 to 25 mCi of technetium Tc 99m ((99m)Tc)-sestamibi intravenously, followed by sestamibi/iodine subtraction SPECT of the neck and chest. At surgery, the location, weight, and histopathologic results of all identified parathyroid tissue were recorded. RESULTS: At surgery, 1 hyperplastic parathyroid gland was resected from each of 13 patients; including 1 undescended gland, 6 parathyroid autotransplants, and 5 mediastinal glands. The mean weight of the resected parathyroid glands was 1707 mg (range, 85-5300 mg). Sestamibi/iodine subtraction SPECT correctly identified and localized all 13 parathyroid glands (100% sensitivity) and was negative in the 1 patient whose surgery was unsuccessful. CONCLUSIONS: The (99m)Tc-sestamibi/(123)I subtraction SPECT is able to correctly localize hyperplastic parathyroid tissue in patients with secondary hyperparathyroidism who have previously undergone parathyroid surgery and is a clinically useful study before reoperation.

Adult↗

Scintigraphic detection of post-pneumonectomy bronchopleural fistulae.

A total of 20 ventilation studies [16 with xenon-133 and four with technetium-99m diethylenetriamine pentaacetic acid (DTPA)] were performed in 11 patients with suspected post-pneumonectomy bronchopleural fistulae. The findings on the ventilation scan were correlated with bronchoscopy, taken as the gold standard for purposes of comparison. The sensitivity and specificity for 133Xe scans were 83% and 100% respectively, while the sensitivity for 99mTc-DTPA aerosol studies was poor at 0%. Special techniques for optimal visualization of the fistulae are enumerated.

Aerosols↗

Parathyroid detection in secondary hyperparathyroidism with 123I/99mTc-sestamibi subtraction single photon emission computed tomography.

123I/99mTc-sestamibi subtraction single photon emission computed tomography (SPECT) has been proposed to detect hyperplastic parathyroid tissue, but the clinical usefulness of this technique in secondary hyperparathyroidism is uncertain. The purpose of this study was to evaluate preoperative parathyroid localization using 123I/99mTc-sestamibi subtraction SPECT in patients with renal failure and secondary hyperparathyroidism. Nineteen patients with chronic renal failure and secondary hyperparathyroidism underwent 123I/99mTc-sestamibi subtraction SPECT imaging preoperatively. None of these patients had undergone previous neck surgery. The location, weight, and histopathological results of all identified parathyroid glands were recorded. Surgery was considered successful in all patients, with resection of a total of 74 hyperplastic parathyroid glands. 123I/99mTc-sestamibi subtraction SPECT correctly identified 57 of these parathyroid glands (77% sensitivity). The mean weight among the true positive glands (n = 57) was 1031 mg (range, 45-7900 mg), and that among the false negative glands (n = 17) was 465 mg (range, 20-1800 mg). This difference between the mean weights was statistically significant (P = 0.018). There was a positive correlation between parathyroid weight and detectability with 123I/99mTc-sestamibi subtraction SPECT (Spearman correlation = 0.28; P = 0.0167). 123I/99mTc-sestamibi subtraction SPECT is able to correctly localize hyperplastic parathyroid glands in patients with renal failure and secondary hyperparathyroidism, but there is a fairly weak relationship between preoperative detection rate and anatomical parathyroid gland size.

Adenoma↗

Preliminary experience with double-phase SPECT using Tc-99m sestamibi in patients with hyperparathyroidism.

BACKGROUND: There is a continual search for a better imaging modality for parathyroid pathology. In recent years, Tc-99m sestamibi has been proposed as an alternative to T1-201 for parathyroid scintigraphy. The purpose of this study is to assess the usefulness of a double-phase Tc-99m sestamibi SPECT technique for parathyroid imaging. METHODS: Sixty-one consecutive patients with hyperparathyroidism were studied. Sixteen had previously undergone unsuccessful surgery for hyperparathyroidism. SPECT imaging of the neck and chest was performed at 15 minutes and again at 2 hours after 20-25 mCi of Tc-99m sestamibi was given intravenously. A positive scan was defined as a region of increased focal uptake that persisted on the delayed images. RESULTS: When compared with surgical findings, double-phase sestamibi SPECT correctly identified 55% (26/ 47) of the parathyroid adenomas in the previously unoperated group, and 91% (10/11) of the parathyroid adenomas in the reoperative group. Double-phase sestamibi SPECT was negative in 92% (109/118) of the normal parathyroid glands in the previously unoperated group, and in 88% (15/17) in the reoperative group. CONCLUSIONS: These preliminary data suggest that double-phase Tc-99m sestamibi SPECT is a promising procedure for the preoperative detection and localization of hyperfunctioning parathyroid tissue, especially in patients with recurrent or persistent postoperative hyperparathyroidism.

Adenoma↗

Comparison of double-phase 99mTc-sestamibi with 123I-99mTc-sestamibi subtraction SPECT in hyperparathyroidism.

OBJECTIVE: Our purpose was to compare double-phase 99mTc-sestamibi single-photon emission computed tomography (SPECT) and simultaneous 123I-99mTc-sestamibi subtraction SPECT for preoperative localization of hyperfunctioning parathyroid tissue in patients with primary hyperparathyroidism. SUBJECTS AND METHODS: Fifteen patients with primary hyperparathyroidism underwent preoperative double-phase 99mTc-sestamibi SPECT and simultaneous 123I-99mTc-sestamibi subtraction SPECT imaging. At surgery, the location, weight, and histopathologic evaluation of all identified parathyroid glands were recorded. RESULTS: At surgery, 17 parathyroid adenomas and 37 normal parathyroid glands were identified. The sensitivity, specificity, and diagnostic accuracy for the detection of parathyroid adenomas were 88%, 97%, and 94%, respectively, for simultaneous 123I-99mTc-sestamibi subtraction SPECT and 53%, 86%, and 76%, respectively, for double-phase 99mTc-sestamibi SPECT. The differences in sensitivity and diagnostic accuracy were statistically significant (p = .031 and p = .016, respectively). CONCLUSION: Compared with double-phase 99mTc-sestamibi SPECT, simultaneous 123I-99mTc-sestamibi subtraction SPECT is a superior imaging study for the preoperative localization of hyperfunctioning parathyroid tissue.

Adenoma↗

Myocardial viability studies using fluorine-18-FDG SPECT: a comparison with fluorine-18-FDG PET.

UNLABELLED: Multidetector SPECT systems equipped with a high-energy, or 511-keV collimator, have been proposed to offer a less expensive alternative to PET in myocardial viability studies with [18F]FDG. The objectives of this investigation included: (a) measuring the physical imaging characteristics of SPECT systems equipped with either a high-energy general-purpose collimator (HE), or the dedicated 511-keV collimator (UH), when imaging 511-keV photons, and comparing them with conventional FDG PET; and (b) directly and quantitatively comparing the diagnostic accuracy of SPECT, with either an UH or HE collimator, to that of PET in myocardial viability studies using 18F-FDG. METHODS: Physical imaging characteristics of SPECT and PET were measured and compared. Both SPECT and PET studies were performed in two groups of 18 patients each, with Group I using HE SPECT and Group II using UH SPECT. Myocardial perfusion studies were also performed using 82Rb PET at rest and during dipyridamole stress to identify areas of persistent hypoperfusion. For each myocardial region with a persistent perfusion defect, a perfusion-metabolism match or mismatch pattern was established independently, based on the results of 18F-FDG SPECT as well as PET. RESULTS: PET is superior to SPECT in all physical imaging characteristics, particularly in sensitivity and contrast resolution. PET had a sensitivity 40-80 times higher than that of SPECT, and its contrast resolution was 40-100% better than SPECT. Between FDG-SPECT using an HE collimator and that using a 511-keV collimator, the latter showed marked reduction in septal penetration (from 56% to 38%), improvement in spatial resolution (from 17 mm to 11 mm FWHM) as well as contrast resolution (from 34% to 45%), while suffering reduced system sensitivity (from 75 to 34 cpm/microCi). Patient studies demonstrated that although FDG-SPECT, using a HE or UH collimator, provided concordant viability information as FDG PET in a large majority of myocardial segments with persistent perfusion defects (88% and 90%, respectively), there is an excellent statistical agreement (kappa = 0.736) between SPECT with UH collimator and PET, while the agreement between SPECT using HE collimator and PET are moderate (kappa = 0.413). CONCLUSION: Despite its markedly inferior physical imaging characteristics compared with PET, SPECT with the dedicated 511-keV collimator offers a low-cost, practical alternative to PET in studying myocardial viability using [18F]FDG. SPECT systems with a high-energy, general-purpose collimator, on the other hand, are inadequate in such studies.

Coronary Circulation↗

Parathyroid localization with technetium-99m-sestamibi: a prospective evaluation.

BACKGROUND: The purpose of this study was to prospectively evaluate parathyroid localization using technetium-99m-sestamibi (MIBI). STUDY DESIGN: Technetium-99m-sestamibi scintigraphy was performed in 124 patients with hyperparathyroidism and the results were correlated with serum calcium and parathyroid hormone (PTH) levels, weight, location, and pathology of parathyroid tissue, and associated thyroid abnormalities. RESULTS: Hyperparathyroidism was primary in 118 patients, secondary in four patients, and tertiary in two patients. The parathyroid pathology was a solitary adenoma in 95 patients (77 percent), double adenoma in five (4 percent), hyperplasia in 14 (11 percent), carcinoma in one (1 percent), and unconfirmed in nine (7 percent) who underwent noncurative parathyroidectomy. Associated thyroid disease was present in 29 (23 percent) patients. Fourteen patients (11 percent) had undergone previous parathyroid exploration. The mean calcium level was 11.4 +/- 0.8 mg/dL (range, 8.3 to 13.7 mg/dL) and the mean adjusted PTH level was 395 +/- 702 (range, 70 to 4,331). The sensitivity and positive predictive value of MIBI scintigraphy were 81 and 89 percent, respectively, in patients with a solitary adenoma and 37 and 100 percent, respectively, in patients with multiglandular disease. The mean adjusted PTH level was higher in patients with true-positive scans compared with false-negative scans (440 +/- 628 compared with 243 +/- 499, p > 0.05). The mean adenoma weight was 1,877 +/- 3,212 mg in patients with a true-positive scan compared with 485 +/- 296 mg with a false-negative scan (p > 0.05). CONCLUSIONS: The sensitivity and positive predictive value of MIBI scintigraphy is comparable to or better than the results reported for other localization procedures. Its lack of sensitivity for detection of multiglandular disease precludes its use in lieu of routine bilateral neck exploration in the management of patients with hyperparathyroidism.

Adolescent↗

Comparison of FDG-PET and sestamibi-SPECT in primary hyperparathyroidism.

UNLABELLED: Preoperative localization of hyperfunctioning parathyroid tissue in patients with primary hyperparathyroidism has been a longstanding diagnostic challenge. This study directly compared FDG-PET and sestamibi-SPECT for preoperative detection of abnormal parathyroid tissue. METHODS: Twenty-one consecutive patients with primary hyperparathyroidism were studied prospectively before surgical neck exploration. SPECT of the neck and chest was performed at 15 min and 2 hr after intravenous 99mTc-sestamibi. Regional body PET was performed 45 min after intravenous FDG. RESULTS: Surgery revealed 19 solitary parathyroid adenomas, 2 parathyroid adenomas in one patient; and 3 hyperplastic parathyroid glands in one patient, and 51 normal parathyroid glands. The diagnostic sensitivities for detection of parathyroid adenomas of 43% (9 of 21) for dual-phase sestamibi-SPECT and 86% (18 of 21) for FDG-PET were significantly different (p < 0.001). The difference in diagnostic specificities of 78% (40 of 51) for FDG-PET and 90% (46 of 51) for dual-phase sestamibi-SPECT approached statistical significance (p = 0.063). CONCLUSION: This study demonstrates that FDG-PET is more sensitive than sestamibi-SPECT in the preoperative localization of parathyroid adenomas in patients with primary hyperparathyroidism.

Adenoma↗

Recurrent postoperative parathyroid carcinoma: FDG-PET and sestamibi-SPECT findings.

Parathyroid carcinoma is a rare cause for primary hyperparathyroidism. A 65-yr-old man presented with postoperative, recurrent hyperparathyroidism after resection of parathyroid carcinoma. Misleading findings were demonstrated by both double-phase 99mTc-sestamibi scintigraphy and MRI. The location and extent of the parathyroid carcinoma were correctly detected by PET using 18F-fluorodeoxyglucose. FDG-PET provided accurate information before reoperation and proved to be valuable for preoperative surgical planning.

Aged↗

Hibernating myocardium versus scar: severity of irreversible decreased myocardial perfusion in prediction of tissue viability.

PURPOSE: To determine whether quantitation of the relative severity of decreased perfusion in irreversible defects on myocardial perfusion images enables differentiation of viable hibernating myocardium from scar. MATERIALS AND METHODS: In 145 patients with previous myocardial infarction, 1,252 regions with irreversible defects proved by means of rubidium-82 rest-stress imaging were analyzed for relative severity (percentage decrease in perfusion). Myocardial tissue viability was determined by means of positron emission tomography with fluorine-18 fluorodeoxyglucose (FDG). RESULTS: The relative decreases in Rb-82 uptake in the 1,252 regions were categorized into nine levels of severity (30% to > or = 70%) in 381 regions of hibernating myocardium and 871 regions of scar. The values of relative decreased perfusion in the irreversible defects alone did not enable differentiation of hibernating myocardium and scar (P = .61). CONCLUSION: The results show no relationship between the relative severity of irreversible perfusion defects and the ability to distinguish between hibernating myocardium and scar.

Cell Survival↗

Primary hyperparathyroidism: preoperative parathyroid imaging with regional body FDG PET.

PURPOSE: To explore the feasibility of use of positron emission tomography (PET) with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) to localize abnormal parathyroid tissue. MATERIALS AND METHODS: Regional body FDG PET with attenuation correction was performed in 17 adult patients with primary hyperparathyroidism (HPT) prior to surgical neck exploration. The regional body FDG PET results were correlated with surgical and histopathologic findings. RESULTS: Surgical neck exploration revealed 18 parathyroid adenomas in 16 patients and four hyperplastic parathyroid glands in one patient. Regional body FDG PET allowed correct localization of 17 of the 18 parathyroid adenomas (94% sensitivity) and two of the four hyperplastic parathyroid glands (50% sensitivity). Three false-positive FDG PET findings were encountered, including two follicular thyroid adenomas. CONCLUSION: Regional body FDG PET is a promising procedure for preoperative localization of pathologic parathyroid tissue in patients with primary HPT.

Adenoma↗

Current status of the clinical applications of cardiac positron emission tomography.

At the present time, positron emission tomography (PET) has evolved into an accurate clinical diagnostic imaging procedure for coronary artery disease that provides unique information, presently unavailable from other imaging modalities, for the management of patients with previous myocardial infarction. The superior accuracy of PET for the diagnosis of coronary artery disease has had a positive influence on the management decision process to perform revascularization. In addition to the superior accuracy of PET compared with single photon emission computed tomography, PET has the advantage of being able to identify viable hibernating myocardium.

Animals↗

Parametric phase display for biventricular function from gated cardiac blood pool single-photon emission tomography.

Complete assessment of biventricular function from planar ECG-gated cardiac blood pool studies has been limited because of the overlap of adjacent activity-containing structures. Theoretically, single-photon emission tomography (SPET) can be used to comprehensively evaluate both ventricles by isolating them from surrounding anatomy. However, an enormous amount of parametric data is generated from gated SPET studies, and much of it is diagnostically irrelevant for ventricular wall motion analysis. To compress this information to a more easily interpretable format, a two-dimensional parametric display has been developed. Fourier analysis of short-axis tomograms from a gated cardiac blood pool SPET study generates three-dimensional, first-harmonic phase data. Circumferential profile data from the parametric tomograms of the right and left ventricle are mapped onto a two-dimensional polar display. This method is demonstrated in a normal patient and in three patients with abnormal ventricular contraction patterns and appears to have potential application for the analysis and characterization of biventricular wall motion.

Aged↗