PubMed Health⌕ Search

Biomedical subjects

D R Schaart

Publications and source records attributed to D R Schaart.

4 recordsLinked to original sources

GATE: a simulation toolkit for PET and SPECT.

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http:/www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.

Computer Simulation↗

On the applicability of the AAPM TG-60/TG-43 dose calculation formalism to intravascular line sources: proposal for an adapted formalism.

Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.

Anisotropy↗

Modelling of a 188W/188Re beta line source for coronary brachytherapy by means of EGS4 Monte Carlo simulations.

In this paper, we present results from three different simulation models that are used to determine the dose distribution around a 188W/188Re coronary brachytherapy source with EGS4 Monte Carlo simulations. The three models are found to give similar results within 10%. Agreement was found with experimental data from measurements in a PMMA phantom. It has been shown that in the therapeutically relevant region the beta line source can be characterized by the radial depth-dose distribution in water.