PubMed Health⌕ Search

Biomedical subjects

D Rancourt

Publications and source records attributed to D Rancourt.

10 recordsLinked to original sources

Germ cell specific promoter drives ectopic transgene expression during embryogenesis.

In this study, we used the male germ cell-specific phosphoglycerate kinase 2 (Pgk2) promoter to generate Pgk2Cre transgenic mice to allow investigation of genes critically involved in meiosis. The Pgk2 promoter had been used previously to target transgene expression to spermatocytes and spermatids in several laboratories including ours. In several Cre targeting experiments using other promoters, ectopic Cre expression had been observed, but the timing and extent of this expression was not analyzed. We demonstrate that in adult mice the Pgk2Cre transgene is expressed specifically in spermatocytes and spermatids, as expected. However, in offspring from matings of Pgk2Cre mice and an H19loxP indicator strain, we discovered that recombination events had occurred in several, but not all, tissues to varying extents. The lacZ-loxP transgenic indicator strain was next used to uncover ectopic Cre expression even in single cells, which indicated that the Pgk2Cre transgene is expressed between days 11 and 15 during embryogenesis in several tissues and organs. Using an RT PCR assay we were unable to detect endogenous Pgk2 mRNA during embryogenesis or in adult tissues other than testis. In conclusion, the Pgk2 promoter is a valid choice for targeting gene expression to meiotic male germ cells, since transient ectopic expression is unlikely to have a discernable effect in most studies, but it may be inappropriate for utilization with Cre recombinase.

Animals↗

Dynamics of pushing.

A standing individual can use several strategies for modulating pushing force magnitude. Using a static model, researchers have shown that the efficacy of those strategies varies considerably. In the present article, the authors propose a human motor control dynamic model for analyzing transients that occur when an individual is asked to modulate force magnitude. According to the model, the impedances of both the upper and the lower limbs influence the time course of force variations and foot placement has a profound effect on pushing force dynamics. With a feet-together posture, the center of pressure has a limited range of motion and changes in force may be preceded by initial changes in the opposite direction; that is, to decrease force, an individual must first increase force. When the feet are placed apart, individuals can move the center of pressure over a much larger range, thereby modulating pushing force magnitude, without reversing behavior, over a larger range of force magnitudes. Therefore, the best way to control pushing force at the hand may be by using the foot.

Biomechanical Phenomena↗

Stability in force-production tasks.

Exerting a force on a mechanical system can induce mechanical instability. To overcome that instability, humans may take advantage of their upper limb mechanical impedance (e.g., hand stiffness). The authors investigated what stiffness is required to maintain static stability and how humans can achieve that stiffness in the context of the task of pushing on a pivoting stick. Results showed that the stiffness required is in the range of measured human upper limb stiffness. To avoid an ill-posed problem, one can better express the requirements for stability as a simple geometrical criterion related to the curvature of the potential energy field at the hand. A planar model of the upper limb revealed that individuals can use both hand rotational and translational stiffness to stabilize a stick. Although hand rotational stiffness does not participate in producing the axial force on the stick, it can significantly contribute to achieving a limb stiffness appropriate for maintaining static stability. Hand rotational stiffness can be important for the design of hand tools, because humans can increase it only by augmenting grip force, a biomechanical factor associated with cumulative trauma injuries of the upper extremities.

Biomechanical Phenomena↗

Increased risk for falling associated with obesity: mathematical modeling of postural control.

Recent epidemiological studies report that obesity is positively related to fracture incidence. In the present experiment, a model of postural control was used to examine the impact of an abnormal distribution of body fat in the abdominal area upon postural stability. Obese and lightweight humanoids were destabilized by imposing a small initial angular speed from a neutral standing position. To avoid a loss of stability yielding a stepping reaction or a fall, an ankle torque is necessary to counteract the perturbation. Three torque parameters--ankle torque onset, time to peak torque, and muscular ankle torque--were entered in a program to simulate the intrinsic variability of the human postural control system. A loss of stability was detected when the center of pressure exceeded stability margins. The most striking observation is the nonlinear increase of torque needed to stabilize the humanoid when the motor response was characterized by delayed temporal parameters. The effect was more pronounced when an anterior position of the center of mass was included in the simulations. This suggests that, when submitted to daily postural stresses and perturbations, obese persons (particularly those with an abnormal distribution of body fat in the abdominal area) may be at higher risk of falling than lightweight individuals.

Abdomen↗

Influence of smoothing window length on electromyogram amplitude estimates.

A systematic, experimental study of the influence of smoothing window length on the signal-to-noise ratio (SNR) of electromyogram (EMG) amplitude estimates is described. Surface EMG waveforms were sampled during nonfatiguing, constant-force, constant-angle contractions of the biceps or triceps muscles, over the range of 10%-75% maximum voluntary contraction. EMG amplitude estimates were computed with eight different EMG processor schemes using smoothing length durations spanning 2.45-500 ms. An SNR was computed from each amplitude estimate (deviations about the mean value of the estimate were considered as noise). Over these window lengths, average +/- standard deviation SNR's ranged from 1.4 +/- 0.28 to 16.2 +/- 5.4 for unwhitened single-channel EMG processing and from 3.2 +/- 0.7 to 37.3 +/- 14.2 for whitened, multiple-channel EMG processing (results pooled across contraction level). It was found that SNR increased with window length in a square root fashion. The shape of this relationship was consistent with classic theoretical predictions, however none of the processors achieved the absolute performance level predicted by the theory. These results are useful in selecting the length of the smoothing window in traditional surface EMG studies. In addition, this study should contribute to the development of EMG processors which dynamically tune the smoothing window length when the EMG amplitude is time varying.

Adult↗

Retinopathy induced in mice by targeted disruption of the rhodopsin gene.

Retinitis pigmentosa (RP) represents the most common mendelian degenerative retinopathy of man, involving death of rod photoreceptors, cone cell degeneration, retinal vessel attenuation and pigmentary deposits. The patient experiences night blindness, usually followed by progressive loss of visual field. Genetic linkage between an autosomal dominant RP locus and rhodopsin, the photoreactive pigment of the rod cells, led to the identification of mutations within the rhodopsin gene in both dominant and recessive forms of RP. To better understand the functional and structural role of rhodopsin in the normal retina and in the pathogenesis of retinal disease, we generated mice carrying a targeted disruption of the rhodopsin gene. Rho-/- mice do not elaborate rod outer segments, losing their photoreceptors over 3 months. There is no rod ERG response in 8-week-old animals. Rho+/- animals retain the majority of their photoreceptors although the inner and outer segments of these cells display some structural disorganization, the outer segments becoming shorter in older mice. These animals should provide a useful genetic background on which to express other mutant opsin transgenes, as well as a model to assess the therapeutic potential of re-introducing functional rhodopsin genes into degenerating retinal tissues.

Age Factors↗

Friction properties of the interface between porous-surfaced metals and tibial cancellous bone.

Friction tests between cancellous bone cubes and porous-surfaced metal plates were conducted in order to determine the mechanical properties of the interface in a knee porous-surfaced metal implant. Bone specimens were obtained from fresh frozen amputated tibiae and three metal plates were chosen: titanium bead porous-surfaced, titanium fiber mesh porous-surfaced, and smooth stainless steel. Results show that the friction curve is highly nonlinear. Friction coefficients measured vary between 0.3 and 1.3. The friction coefficient of the interface is independent of the excision site of the bone cubes and of the magnitude of the rate of relative displacement at the interface. The friction coefficient appears to vary slightly with the normal contact pressure for all the metal surfaces. Both porous surfaces have statistically a higher friction coefficient than the smooth surface. This is likely due to the presence of surface asperities whereby the metal ploughs the bone surface. However, no significant differences is observed between bead and fiber mesh types.

Biocompatible Materials↗

Mutagen content of table wines made from various grape species and hybrid cultivars.

The mutagen content of wines produced from the European Vitis vinifera grapes was compared with that of wines produced from hybrids of V. vinifera and species indigenous to North America. Mutagens were extracted on an XAD-2 Amberlite resin column and activated with S-9 and/or faecalase in the Salmonella/microsomal mutagen assay. All white wines had insignificant mutagen levels. The only red wine to produce statistically significant reversion frequencies was that made from the Concord grape. The mutagens were shown to be extracted from the grape skins during fermentation.

Fermentation↗

Estimation and application of EMG amplitude during dynamic contractions.

The sections above have described an EMG amplitude estimator and an initial application of this estimator to the EMG-torque problem. The amplitude estimator consists of six stages. In the first stage, motion artifact and power-line interference are attenuated. Motion artifact is typically removed with a highpass filter. Elimination of power-line noise is more difficult. Commercial systems tend to use notch filters, accepting the concomitant loss of "true" signal power in exchange for simplicity and robustness. Adaptive methods may be preferable, however, to preserve more "true" signal power. In stage two, the signal is whitened. One fixed whitening technique and two adaptive whitening methods were described. For low-amplitude levels, the adaptive whitening technique that includes adaptive noise cancellation may be necessary. In stage three, multiple EMG channels (all overlying the same muscle) are combined. For most applications, simple gain normalization is all that is required. Stage four rectifies the signal and then applies the power law required to demodulate the signal. In stage six, the inverse of the power law is applied to relinearize the signal. Direct comparison of MAV (first power) to RMS (second power) processing demonstrates little difference between the two. Therefore, unless there is reason to believe that the EMG density departs strongly from that found in the existing studies, RMS and MAV processing are essentially identical. In stage five, the demodulated samples are averaged across all channels and then smoothed (time averaged) to reduce the variance of the amplitude estimate, but at the expense of increasing the bias. For best performance, the window length that best trades off variance and bias error is selected. The advanced EMG processing was next applied to dynamic EMG-torque estimation about the elbow joint. Results showed that improved EMG amplitude estimates led to improved EMG-torque estimates. An initial comparison of different system-identification techniques and model orders was reported. It is expected that these advanced processing and identification algorithms will also improve performance in other EMG applications, including myoelectrically controlled prostheses, biofeedback, and ergonomic assessment.

Algorithms↗

Cyclic traction machine for long-term culture of fibroblast-populated collagen gels.

Our research group has been investigating the effect of cyclic deformations on the evolution of fibroblast populated collagen gels (FPCG). Since existing traction machines are not designed for such an application, we had to design a cyclic traction machine adapted to tissue culture inside an incubator over an extended period of time. Biocompatible materials were used for fabrication to allow for easy sterilization and to prevent any adverse reaction from the tissue. The traction machine is based on a computer-controlled stepping motor system for easy adjustment of the deformation amplitude and frequency. The maximum stretching speed achieved is around 1 mm/s. The traction machine can measure FPCG mechanical properties and perform rupture tests to determine its ultimate strength. Several FPCGs have been successfully cultured with the machine for up to four weeks without any adverse reaction.

Biocompatible Materials↗