Patient exposure requirements for high contrast resolution in digital radiographic systems.

The contrast resolution of modern digital radiographic equipment is primarily limited by quantum mottle. The derivation of the contrast resolution of a system as a function of radiation exposure is presented. Calculations based on this derivation show that achieving 0.8% contrast resolution (128 meaningful gray levels) with 1-mm spatial resolution may require a patient exposure of 1.7 rad (1.7 cGy) per image of a thick body part (20 cm tissue). Acceptable clinical studies often can be obtained with only 5% contrast resolution (20 meaningful shades of gray), but even this level of contrast may require a patient exposure of nearly 90 mrad (0.9 mGy) per image. A comparison of three commonly used methods of reducing patient radiation exposure (pulsed imaging, temporal averaging, and recursive filtering) shows that, in theory, a pulsed system achieves the highest contrast resolution for the same total exposure.

Computers↗

Gray scale of ultrasound instruments: evaluation using a test object.

B-mode scans of castor oil in a wedge-shaped container provide gray level maps. The relation between the gray levels and the amounts of absorbing medium can be used to measure the effects of electronic gain, transducer characteristics, and the overall gray level performance of different ultrasound systems. We report results from four units and ten transducers for varying scanning depths.

Castor Oil↗

Normalization (division) versus subtraction of digitized images.

The propagation of noise in digitized images arrived at by algebraic manipulation of two images has been investigated. The algebraic manipulations investigated were logarithmic subtraction, linear subtraction, and division of the two images. The two images were identical except for the presence of a contrast-adding component in one of them. The two extreme cases of video-fluoroscope system behavior, gray level proportional to incident photon flux and gray level proportional to the product of thickness and linear attenuation coefficient, were investigated. The ratio of signal to noise was calculated for each of these cases and a figure of merit established for the ratio of signal to noise of the division process versus each of the subtraction processes for each of the two fluoroscopic system behaviors. In all cases, this figure of merit is greater than unity. Values of these figures of merit for iodine concentrations of 5, 20, and 300 mg/cm3 are given in the paper. The process of division appears to be advantageous as a signal-to-noise enhancer for all applications not requiring a quantitative relationship between image contrast and photon flux.

Fluoroscopy↗

Quantum noise in detectors.

The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribution in the number of x-ray photons absorbed by a detector. The standard deviation (quantum noise) in this distribution is very well approximated by the commonly used and experimentally verified quantity square root N where N is the average number of x-ray number of x-ray photons absorbed by the detector.

Information Theory↗