Gender differences in real-world hearing protector attenuation.

This research investigated the possibility of differences in real-world attenuation attributable to gender. A total of 160 subjects, 80 males and 80 females, under the age of 45 years, and with normal hearing, were tested. Subjects were assigned to four hearing protector categories with the restriction that there were 20 males and 20 females in each group. The devices chosen for study were the E-A-R expandable foam plug, the Willson Sound Silencer premolded vinyl plug with double flange, the Bilsom Soft polyethylene encapsulated glass fiber plug, and the MSA Ear Defender (V-51R) premolded vinyl plug with single flange. Binaural headphone detection thresholds were measured in quiet with the open ear, and subsequently with protectors fitted binaurally for one-third octave noise bands centered at 250, 500, 1000, 3150 and 6300 Hz. The results indicated that attenuation scores achieved by females were less than those observed for males when the device was sold in only one size. Apart from the question of adequate sizing, for two of the insert protectors studied, mean achieved attenuation fell short of the manufacturer's specifications by as much as 18 dB, for particular frequencies tested. The relatively wide variation in scores observed for all four protectors in spite of experimenter-fit could not be accounted for by differences in either hearing threshold across subjects or by size of plug fit, for those devices available in several sizes.

Adolescent↗

The effect of wearing time on hearing protector attenuation.

The effect of wearing time on attenuation was measured for three insert protectors, the E-A-R expandable foam, the Willson premolded vinyl with double flange, and the Bilsom soft polyethylene encapsulated glass fiber. Binaural detection thresholds in quiet were measured with and without the protectors worn at the initial insertion and after a period of one to one and one-half hours during which lunch was eaten. The difference between the open and closed ear thresholds provided a measure of attenuation. The subjects were 12 normal adults aged 20 to 37 years. Each participated in the three hearing protector conditions. The stimuli used were one-third octave noise bands centered at 500 Hz and 3150 Hz. The results showed that wearing time may reduce attenuation by as much as 10 dB, depending on the type of protector chosen.

Adult↗