PubMed Health⌕ Search

Biomedical subjects

D S Baim

Publications and source records attributed to D S Baim.

At least 19 recordsLinked to original sources

Short- and intermediate-term clinical outcomes from direct myocardial laser revascularization guided by biosense left ventricular electromechanical mapping.

BACKGROUND: Direct myocardial revascularization (DMR) has been examined as an alternative treatment for patients with chronic refractory myocardial ischemic syndromes who are not candidates for conventional coronary revascularization. Methods and Results-We used left ventricular electromagnetic guidance in 77 patients with chronic refractory angina (56 men, mean age 61+/-11 years, ejection fraction 0.48+/-0.11) to perform percutaneous DMR with an Ho:YAG laser at 2 J/pulse. Procedural success (laser channels placed in prespecified target zones) was achieved in 76 of 77 patients with an average of 26+/-10 channels (range 11 to 50 channels). The rate of major in-hospital cardiac adverse events was 2.6%, with no deaths or emergency operations, 1 patient with postprocedural pericardiocentesis, and 1 patient with minor embolic stroke. The rate of out-of-hospital adverse cardiac events (up to 6 months) was 2.6%, with 1 patient with myocardial infarction and 1 patient with stroke. Exercise duration after DMR increased from 387+/-179 to 454+/-166 seconds at 1 month and to 479+/-161 seconds at 6 months (P=0.0001). The time to onset of angina increased from 293+/-167 to 377+/-176 seconds at 1 month and to 414+/-169 seconds at 6 months (P=0.0001). Importantly, the time to ST-segment depression (>/=1 mm) also increased from 327+/-178 to 400+/-172 seconds at 1 month and to 436+/-175 seconds at 6 months (P=0.001). Angina (Canadian Cardiovascular Society classification) improved from 3.3+/-0.5 to 2.0+/-1.2 at 6 months (P<0.001). Nuclear perfusion imaging studies with a dual-isotope technique, however, showed no significant improvements at 1 or 6 months. CONCLUSIONS: Percutaneous DMR guided by left ventricular mapping is feasible and safe and reveals improved angina and prolonged exercise duration for up to a 6-month follow-up.

Adult↗

Impact of end-stage renal disease on clinical and angiographic outcomes after coronary stenting.

Although patients with end-stage renal disease (ESRD) are at high risk for restenosis that requires repeat revascularization after balloon angioplasty, their restenosis rate after coronary stenting is still unknown. Over a 4-year period, we performed coronary stenting on 40 lesions in 34 patients with ESRD. We compared these lesions with 80 lesions from patients without renal disease who underwent coronary stenting in the STARS and WINS clinical trials, matched for treatment site, diabetes, lesion length, and reference vessel diameter. Quantitative coronary angiography was performed on all lesions and clinical outcomes were assessed at 9-month follow-up. Clinical and angiographic characteristics were well matched between the 2 groups and acute clinical success rates were similar. Despite comparable initial angiographic results over the 9-month follow-up period, repeat target lesion revascularization was twice as frequent in the ESRD group compared with the control group (35% vs 16%, p <0.05). After adjusting for differences in postprocedural minimum lumen diameter and other angiographic and clinical characteristics, ESRD remained the most important predictor of late target lesion revascularization (relative risk = 2.3, p = 0.04). In addition, overall 9-month mortality was higher for ESRD patients than for the control population (18% vs 2%, p <0.01). Thus, despite similar angiographic results, patients with ESRD are at higher risk for target lesion revascularization after coronary stenting than controls. Nonetheless, most patients with ESRD do not develop restenosis after stent placement, suggesting an important role for stenting in the management of this challenging population.

Aged↗

Usefulness of stent length in predicting in-stent restenosis (the MULTI-LINK stent trials).

The cumulative experience of 4 clinical trials using the MULTI-LINK coronary stent design was analyzed. Multivariable logistic regression identified postprocedure in-stent minimum lumen diameter (p = 0.0001), stent length (p = 0.0038), smoking (p = 0.0105). and diabetes (p = 0.0803) as the most important predictors of in-stent restenosis at late (6- to 9-month) angiographic follow-up.

Adult↗

Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study.

BACKGROUND: Intravascular ultrasound (IVUS) can assess stent geometry more accurately than angiography. Several studies have demonstrated that the degree of stent expansion as measured by IVUS directly correlated to clinical outcome. However, it is unclear if routine ultrasound guidance of stent implantation improves clinical outcome as compared with angiographic guidance alone. METHODS AND RESULTS: The CRUISE (Can Routine Ultrasound Influence Stent Expansion) study, a multicenter study IVUS substudy of the Stent Anti-thrombotic Regimen Study, was designed to assess the impact of IVUS on stent deployment in the high-pressure era. Nine centers were prospectively assigned to stent deployment with the use of ultrasound guidance and 7 centers to angiographic guidance alone with documentary (blinded) IVUS at the conclusion of the procedure. A total of 525 patients were enrolled with completed quantitative coronary angiography, quantitative coronary ultrasound, and clinical events adjudicated at 9 months for 499 patients. The IVUS-guided group had a larger minimal lumen diameter (2.9+/-0.4 versus 2.7+/-0. 5 mm, P<0.001) by quantitative coronary angiography and a larger minimal stent area (7.78+/-1.72 versus 7.06+/-2.13 mm(2), P<0.001) by quantitative coronary ultrasound. Target vessel revascularization, defined as clinically driven repeat interventional or surgical therapy of the index vessel at 9 month-follow-up, occurred significantly less frequently in the IVUS-guided group (8.5% versus 15.3%, P<0.05; relative reduction of 44%). CONCLUSIONS: These data suggest that ultrasound guidance of stent implantation may result in more effective stent expansion compared with angiographic guidance alone.

Aspirin↗

Suture-mediated closure of the femoral access site after cardiac catheterization: results of the suture to ambulate aNd discharge (STAND I and STAND II) trials.

Despite advances in other aspects of cardiac catheterization, manual or mechanical compression followed by 4 to 8 hours of bed rest remains the mainstay of postprocedural femoral access site management. Suture-mediated closure may prove to be an effective alternative, offering earlier sheath removal and ambulation, and potentially a reduction in hemorrhagic complications. The Suture To Ambulate aNd Discharge trial (STAND I) evaluated the 6Fr Techstar device in 200 patients undergoing diagnostic procedures, with successful hemostasis achieved in 99% of patients (94% with suture closure only) in a median of 13 minutes, and 1% major complications. STAND II randomized 515 patients undergoing diagnostic or interventional procedures to use of the 8Fr or 10Fr Prostar-Plus device versus traditional compression. Successful suture-mediated hemostasis was achieved in 97.6% of patients (91.2% by the device alone) compared with 98.9% of patients with compression (p = NS). Major complication rates were 2.4% and 1.1%, and met the Blackwelder's test for equivalency (p <0.05). Median time to hemostasis (19 vs 243 minutes, p <0.01) and time to ambulation (3.9 vs 14.8 hours, p <0.01) were significantly shorter for suture-mediated closure. Suture-mediated closure of the arterial puncture site thus affords reliable immediate hemostasis and shortens the time to ambulation without significantly increasing the risk of local complications.

Cardiac Catheterization↗

Relation of coronary artery size to one-year clinical events after new device angioplasty of native coronary arteries (a New Approach to Coronary Intervention [NACI] Registry Report).

The influence of vessel size on clinical and angiographic outcomes after new device angioplasty has not been well documented. We reviewed clinical and angiographic outcomes of 2,044 patients undergoing new device angioplasty of native vessels enrolled in the New Approaches to Coronary Interventions (NACI) Registry. Quantitative angiography was performed using standard methods. Patients were divided into 3 groups according to reference vessel diameter (RVD) (<2.75, 2.75 to 3.25, and >3.25 mm). Patients with the smallest vessels had a higher incidence of diabetes (26% vs. 16%, p<0.01), multivessel disease (50% vs. 45%, p<0.01), left anterior descending coronary artery disease (61% vs. 39% p<0.01), and in general, more severe baseline lesion characteristics than patients with larger (>3.25 mm) vessels. Absolute baseline and final minimal lumen diameter (MLD) was also smaller in patients with RVD <2.75 mm despite similar final percent diameter stenosis. Although in-hospital events were similar, patients who underwent interventions in vessels <2.75 mm had an increased incidence of death (p<0.01), surgical revascularization (p<0.05), and target lesion revascularization (TLR) (p<0.01) at 1 year. Multivariate analysis by vessel size showed a stepwise increase in the risk of TLR by 1 year in patients with the smaller RVD (p = 0.0001) and the combined end point of 1 year death/Q wave-myocardial infarction/TLR (p = 0.02). Thus, despite similar early clinical events among patients undergoing new device angioplasty, patients who underwent treatment of smaller vessels had a significantly increased risk of major adverse clinical events and particularly TLR by 1 year after new device angioplasty of native coronary arteries.

Angioplasty↗

Outcome of patients with acute myocardial infarction who are ineligible for primary angioplasty trials.

We determined acute outcome in 148 consecutive patients with ST segment elevation myocardial infarction undergoing angioplasty including 72 patients (48.7%) considered ineligible for primary angioplasty trials. Overall, in-hospital mortality for acute infarct angioplasty was 12%, with fivefold higher mortality in the trial-ineligible group (21% vs. 4%, P = 0.003). Thus, primary angioplasty trials continue to exclude nearly 50% of acute infarction patients and reported mortality rates of primary angioplasty trials are likely to be significantly lower than the unselected in-hospital mortality rates. Cathet. Cardiovasc. Intervent. 49:237-243, 2000.

Angioplasty, Balloon, Coronary↗

Importance of lesion length on new device angioplasty of native coronary arteries. NACI Investigators. New Approaches to Coronary Interventions.

The influence of lesion length on early and late outcomes after new device angioplasty has not been well documented. We reviewed the clinical and angiographic outcomes of 2,980 patients (3,902 lesions) undergoing new device angioplasty of native vessels enrolled in the New Approaches to Coronary Interventions (NACI) Registry. Patients were divided into three groups according to the longest lesion length (< 10, 10-20, and > 20 mm) treated. Patients with the longest lesions had more multivessel disease (56.9% vs. 49.0%, P<0.05), right coronary artery disease (52.7% vs. 32.0%, P<0.001), and total occlusions (19.1% vs. 2.5%, P<0.001) than patients with shorter lesions. Longest lesions had the smallest minimal lumen diameter (P<0.001) at baseline and at the end of the procedure. Although in-hospital events were similar, there were differences in clinical outcomes at 1 year due mainly to more target lesion revascularization in the longest lesion group (P<0.01). Multivariate analysis showed that each 1-mm increase in lesion length was associated with an increase relative risk of 1.014 (95% CI, 1.004-1.025) for target lesion revascularization at 1 year. We conclude that despite similar early clinical events, patients undergoing new device angioplasty of longer lesions have more target lesion revascularization at 1 year.

Aged↗

In vivo assessment of stent expansion and recoil in normal porcine coronary arteries: differential outcome by stent design.

BACKGROUND: Despite the routine use of high pressure, coronary stents generally fail to achieve a cross-sectional area (CSA) >60% to 80% of the nominal CSA of their dilating balloon. The extent to which incomplete balloon expansion and postdeflation stent recoil contribute to this failure has not been fully evaluated. METHODS AND RESULTS: Thirty-two stents (8 Gianturco-Roubin II, 8 Palmaz-Schatz, 8 MultiLink, and 8 NIR) were deployed in nondiseased coronary arteries of 8 Yorkshire pigs. All stents were then expanded according to 1 of 3 balloon strategies: appropriately sized compliant balloons, oversized compliant balloons, or oversized noncompliant balloons. Continuous ultrasound imaging was performed during stepwise balloon inflation and deflation, with an 0.018-in imaging core positioned within the guidewire lumen of the balloon. In these normal arteries, balloon underexpansion relative to the nominal size was not observed. After balloon deflation, however, all stents showed significant recoil from their maximum inflated CSA. Recoil was significantly greater for the coil Gianturco-Roubin II stent (30% CSA) than for the 3 slotted-tube stent designs (15% to 17% CSA). CONCLUSIONS: In normal, compliant coronary arteries, stent recoil is the predominant mechanism by which stents fail to achieve the nominal CSA of their dilating balloon. The magnitude of this in vivo stent recoil is significantly greater than reported from bench testing and varies with stent design (coil versus slotted tube). Postdilatation strategies that result in controlled stent overexpansion are needed to overcome this recoil phenomenon and result in a final stent CSA that approximates the reference artery CSA.

Angioplasty, Balloon, Coronary↗

Comparative analysis of early and late angiographic outcomes using two quantitative algorithms in the Balloon versus Optimal Atherectomy Trial (BOAT).

Although substantial intersystem variability has been shown among several commercially available quantitative angiographic (QA) analysis algorithms, no previous study has compared the angiographic findings using 2 different QA systems performed at the same central angiographic laboratory. The purpose of this study was to compare the early and late QA results obtained with the CMS (MEDIS) and ARTREK (ImageComm) QA systems in the Balloon versus Optimal Atherectomy Trial. Directional atherectomy (n = 496) or balloon angioplasty (n = 490) was performed in 986 patients; late QA follow-up was available in 767 patients (77.7%). QA analysis was performed by 2 independent observers using the CMS and ARTREK systems. Correlation between the 2 QA systems for baseline measurements was good (Pearson's R = 0.78), although the CMS system resulted in larger baseline reference diameter (RD) (3.22 +/- 0.45 vs 3.07 +/- 0.40 mm; p <0.0001) and baseline minimal lumen diameters (MLD) (1.05 +/- 0.35 vs 0.92 +/- 0.32; mm p <0.0001) than the ARTREK system. The final and follow-up RD (+0.17 and +0.11 mm, respectively) were also larger using the CMS system. In contrast, the final and follow-up measurements of MLD and percent diameter stenosis were not significantly different using the 2 QA systems. The QA system did not affect the ability to detect a difference in restenosis rates (>50% follow-up diameter stenosis) between the 2 treatment groups (CMS, directional atherectomy [31.8%]; balloon angioplasty [40.5%]; p = 0.013 and ARTREK, directional atherectomy [33.9%], balloon angioplasty [41.3%]; p = 0.036). Only lesion irregularity contributed to the difference in baseline measurements of MLD and percent diameter stenosis. We conclude that important differences in measurements of RD, baseline MLD, and percent diameter stenosis were noted using the CMS and ARTREK systems. Both systems, however, were able to detect a treatment benefit associated with directional atherectomy in BOAT. The comparability of other angiographic systems will require similar evaluation in other studies.

Algorithms↗

An embolization containment device.

A coaxial catheter system for containment of distal embolization is described. Utilizing a novel 0.014" hypotube with a distal elastomeric occlusion balloon, the PercuSurge GuardWire functions as a guidewire while trapping distal embolization resulting from more proximal intervention. The particulate debris is evacuated with a single operator exchange aspiration catheter (Export catheter) prior to deflation of the distal occlusion balloon. This animal study confirmed the feasibility of concept. The system was easily delivered through tortuous coronary anatomy. The GuardWire served as an adequate rail for delivery of dilatation balloons and a multitude of stents. There was no evidence of deep wall damage from low-pressure inflation and apposition of the distal occlusion balloon.

Animals↗

Short- and long-term histopathologic evaluation of stenting using a self-expanding nitinol stent in pig carotid and iliac arteries.

Stenting is increasingly being used to treat carotid artery disease. However, complications including distal embolization, stent thrombosis, stent collapse from external compression, the need for high-pressure inflation with increased neointimal response, or balloon rupture during stent expansion and stent loss are all potential problems and of concern. To address each of these specific concerns, a new stent was designed, which is self-expandable, made of nitinol, with temperature-dependent superelastic properties, and with high vessel wall surface coverage. Since this device has a number of novel characteristics, we aimed to assess the short- and long-term histopathologic response in pig carotid and iliac arteries. Single stents were deployed in pig carotid and iliac arteries after overstretch balloon injury. Angiograms were performed pre- and poststenting and prior to sacrifice. Intravascular ultrasound was used before implantation to determine vessel size. Vessels were examined histologically at 1 month (n = 6) and 6 months (n = 6) for morphometric analysis, hemorrhage and thrombus, endothelialization, and inflammatory and fibrotic responses. There was a 100% angiographic success rate at implantation. In one case, it was determined histologically that a single stent was implanted in a dissection plane of a pig's left iliac artery and was occluded by organized thrombus, with the true lumen being patent. At 6-month follow-up, this was the only evidence of a single stent occlusion, with flow adjacent to the stent in the true lumen. In the other vessels, the stents showed good vessel wall-stent apposition and the lumens were patent with a concentric and thin neointima. Inflammatory cells were rare and there were no mural thrombi. Coverage of the vessel wall by endothelial-like cells was complete at 1 month. The novel nitinol EndoStent appears to have favorable biocompatibility with minimal thrombus deposition or inflammatory response, and its use is feasible for clinical application in carotid and iliac arteries.

Alloys↗

Acute and nine-month clinical outcomes after "suboptimal" coronary stenting: results from the STent Anti-thrombotic Regimen Study (STARS) registry.

OBJECTIVES: This registry collected the 30-day and 9-month clinical outcomes of patients whose coronary stent implantation was suboptimal, and compared them with the cohort of patients with "optimal" stenting in the randomized portion of the STent Anti-thrombotic Regimen Study (STARS) trial. BACKGROUND: Although "optimal" stenting combined with an aspirin and ticlopidine regimen carries a low (0.5%) incidence of subacute stent thrombosis, only limited data are available for patients in whom stents are deployed suboptimally. METHODS: In the STARS, 312 (15.9%) of 1,965 patients enrolled were excluded from participation in the randomized trial based on a perceived "suboptimal" result of coronary stenting. Of these, 265 patients met prespecified criteria for suboptimal stenting, and were followed in a parallel registry, which was compared with the randomized STARS optimal stenting cohort. The primary end point was a 30-day composite of death, emergent target lesion revascularization, angiographic thrombosis of the target vessel without revascularization and nonfatal myocardial infarction (MI) unrelated to direct procedural complications. RESULTS: Registry patients had a similar frequency of the primary end point compared with the overall randomized cohort (3.0% vs. 2.2%), with this end point correlating to use of multiple stents, smaller final lumen diameter and absence of ticlopidine from the poststent regimen. Overall 30-day mortality (1.1% vs. 0.06%, p = 0.009) and periprocedural non-Q wave MI (8.7% vs. 4.2%, p = 0.003) were more frequent in registry patients, and appeared to be related to acute procedural complications. Clinical restenosis was significantly higher for registry patients (26.8% vs. 16.0%, p = 0.001), relating to greater prevalence of independent predictors such as smaller final lumen diameter and multiple stent use. CONCLUSIONS: In the STARS registry, the inability to perform optimal stenting correlated with smaller final lumen diameter and longer stent length. With ticlopidine-containing regimens, the acute clinical results of "suboptimal" stent deployment are clinically acceptable, although they are not quite as good as those of optimal stenting using similar drug therapy.

Acute Disease↗