PubMed Health⌕ Search

Biomedical subjects

D S Rimkus

Publications and source records attributed to D S Rimkus.

9 recordsLinked to original sources

Efficacy of morphine sulfate-augmented hepatobiliary imaging in acute cholecystitis.

OBJECTIVE: A review of the English language literature was performed to determine the sensitivity and specificity of morphine sulfate-augmented hepatobiliary imaging for acute cholecystitis. Twenty publications, involving 914 patients, were reviewed from journals published between 1984 and 1999. The analysis of these patients has resulted in the largest combined review study to date. The sensitivity and specificity of morphine-augmented hepatobiliary imaging were calculated to be 96.1% and 88.6%, respectively. After reading this paper, the nuclear medicine technologist should be able to: (a) discuss the clinical use of morphine augmentation during hepatobiliary imaging; and (b) state the sensitivity and specificity of morphine sulfate-augmented hepatobiliary imaging.

Acute Disease↗

Tc-99 hexamethylpropyleneamineoxide scanning for the detection of acute appendicitis.

BACKGROUND: Patients with acute lower abdominal pain remain a diagnostic challenge. Although acute appendicitis is the most common surgical disorder, its accurate and timely diagnosis can be difficult. Historically, females of childbearing age are the most difficult patient group in whom to make the diagnosis of acute appendicitis; they have reported negative laparotomy rates ranging from 30 to 50 percent. Tc-99 hexamethylpropyleneamineoxide (HMPAO) labeled leukocyte scan has previously been shown to be very accurate in the detection of acute appendicitis. STUDY DESIGN: One year ago, a blinded study using Tc-99 HMPAO labeled leukocyte scan was reported for the detection of acute appendicitis. That study consisted of 27 patients who presented with abdominal pain. The present report is a follow-up study of 37 additional patients in whom the Tc-99 HMPAO leukocyte scan was used to diagnose or discount acute appendicitis. RESULTS: Twenty-seven patients had histologically proved acute appendicitis. Twenty-three of these were correctly diagnosed using the leukocyte scan, for a sensitivity rate of 85 percent. The overall specificity rate was 93 percent, with an overall accuracy rate of 89 percent. Thirty-one of 64 patients were females of reproductive age and represented 56 percent of all patients in the study with appendicitis. In this group, the Tc-99 HMPAO leukocyte scan had a sensitivity rate of 87 percent, specificity rate of 92 percent, and an overall accuracy rate of 89 percent. The Tc-99 HMPAO leukocyte scan also proved to be valuable in the diagnosis of other intra-abdominal inflammatory conditions. Eight scans interpreted as negative for acute appendicitis were positive for other conditions, including five that were positive for diverticulitis, one for a tumor, one for a tubo-ovarian abscess, and one for a small intestinal infarction. CONCLUSIONS: The Tc-99 HMPAO leukocyte scan is a highly accurate, diagnostic, and minimally invasive test of use in patients with abdominal pain of unclear cause, in which the differential diagnosis includes acute appendicitis. It is of particular value in females of childbearing age, in whom the cause of lower abdominal pain is unclear.

Abdominal Pain↗

Detection of acute appendicitis by technetium 99 HMPAO scanning.

The diagnosis of acute appendicitis can be difficult. Barium enemas, computed tomography (CT) scans, ultrasound examinations and Indium scans are used to aid in making the diagnosis with varying degrees of success. This blinded, prospective study reports the use of a Technetium 99-m Hexamethylpropyleneamineoxide (HMPAO) labelled white blood cell scan in 30 patients with suspected appendicitis. Autologous white blood counts from 25 cc of whole blood labelled with Tc-99 HMPAO were reinjected into patients. Abdominal imaging was performed at a half hour postinjection and repeated at 2 to 4 hours postinjection. A positive study showed an increased isotope uptake in the right lower quadrant. Nineteen patients had histologically proven appendicitis. Three of these patients were excluded because they were operated on before scan completion. Thirteen of the remaining 16 patients with appendicitis had positive studies (false negative rate = 19%). All patients without appendicitis had either negative scans or scans that detected other intra-abdominal diseases, such as diverticulitis, tubo-ovarian abscess, or small bowel infarction (false positive rate = 0%). Overall, this Tc-99 HMPAO study had a sensitivity of 81 per cent, a specificity of 100 per cent and an overall accuracy of 89 per cent. The 4-hour Tc-99 HMPAO WBC scan is a useful, noninvasive test for confirming the clinical diagnosis of acute appendicitis, but it may prove more valuable as a diagnostic study to rule out appendicitis in patients that have abdominal pain of unclear etiology.

Acute Disease↗

Lung ventilation scanning with a new carbon particle radioaerosol (Technegas). Preliminary patient studies.

A new Tc-99m labeled carbon particle aerosol ("Technegas") has been developed for lung ventilation scanning. This is the first reported clinical study of this agent in the United States. A total of 23 subjects were studied. Thirteen had comparative Xe-133 studies, and in seven patients pulmonary angiograms were available. The Technegas study agreed closely with the Xe-133 results in 10 out of 13 patients, while the pulmonary angiogram confirmed the Technegas and perfusion scan findings in seven out of seven cases. The Technegas scan was easily performed and well tolerated by all patients. If further clinical trials confirm these preliminary findings, Technegas may become the preferred agent for lung ventilation scanning.

Aerosols↗

Space medicine--a review of current concepts.

Space medicine deals with the branch of research involved with the adaptation of humans to the unique environment of space. More than 100 people have traveled in space. The day will come when some human beings will spend all their time in space. Medical problems encountered in space, such as motion sickness, negative nitrogen and calcium balance, anemia and radiation exposure, are issues that already affect medical practice outside aerospace medicine.

Aerospace Medicine↗

Gold-195m first-pass radionuclide ventriculography, thallium-201 single-photon emission CT, and 12-lead ECG stress testing as a combined procedure.

Graded, sequential, rest/exercise, gold-195m (Au-195m) (T1/2 = 30 seconds), first-pass ventriculography and thallium-201 (T1-201) single-photon emission computed tomography (SPECT) were performed simultaneously during a single, electrocardiograph-monitored, bicycle stress test in 24 individuals. The technical aspects and logistics involved in performing this combined radionuclide study are stressed in this preliminary report. Fourteen healthy volunteers each had a normal left ventricular ejection fraction and wall-motion response, along with normal Tl-201 perfusion and washout, as determined by both visual and quantitative analysis of the tomographic sections. Each of ten patients with coronary artery disease had at least one abnormality of these parameters. We suggest that it is technically feasible to evaluate both cardiac function and myocardial perfusion simultaneously by combining Au-195m ventriculography and T1-201 SPECT imaging into a single, noninvasive, diagnostic package.

Adult↗

Digital tomosynthesis: phantom and patient studies with a prototype unit.

A prototype digital linear tomographic system has been developed and used in patient and phantom studies. Phantom work demonstrated 0.6 line pairs/mm of spatial resolution, a slice thickness of 5 mm to 6 mm, range of reconstruction of 1 cm to 20 cm above tabletop, reconstruction time of 2 to 45 seconds per slice depending on matrix size, and a 280 mm field of view at the tabletop. Patient studies were conducted in three categories: renal imaging in 8 patients during intravenous urography (IVU); central airways imaging in 4 patients undergoing laser resection of endobronchial tumor; the knee of one volunteer. The digital tomograms from IVU studies were similar to the conventional film tomograms, and the only parenchymal abnormality, a renal cyst, was identified by both modalities. Digital tomograms of the mediastinum were superior to the chest radiographs in determining the patency of the central airways. With further development, digital tomosynthesis could offer greater spatial resolution, faster reconstructions, and less radiation than computed tomography (CT) or conventional tomography.

Humans↗