PubMed Health⌕ Search

Biomedical subjects

D Saini

Publications and source records attributed to D Saini.

2 recordsLinked to original sources

Simplified dispatch-assisted CPR instructions outperform standard protocol.

OBJECTIVE: Dispatch-assisted chest compressions only CPR (CC-CPR) has gained widespread acceptance, and recent research suggests that increasing the proportion of compression time during CPR may increase survival from out-of-hospital cardiac arrest. We created a simplified CC-CPR protocol to reduce time to start chest compressions and to increase the proportion of time spent delivering chest compressions. This simplified protocol was compared to a published protocol, Medical Priority Dispatch System (MPDS) Version 11.2, recommended by the National Academies of Emergency Dispatch. METHODS: Subjects were randomized to the MPDS v11.2 protocol or a simplified protocol. Data was recorded from a Laerdal Resusci Anne Skillreporter manikin. A simulated emergency medical dispatcher, contacted by cell phone, delivered standardized instructions for both protocols. Outcomes included chest compression rate, depth, hand position, full release, overall proportion of compressions without error, time to start of CPR and total hands-off chest time. Proportions were analyzed by Wilcoxon's Rank Sum tests and time variables with Welch ANOVA and Wilcoxon's Rank Sum test. All tests used a two-sided alpha-level of 0.05. RESULTS: One hundred and seventeen subjects were randomized prospectively, 58 to the standard protocol and 59 to the simplified protocol. The average age of subjects in both groups was 25 years old. For both groups, the compression rate was equivalent (104 simplified versus 94 MPDS, p = 0.13), as was the proportion with total release (1.0 simplified versus 1.0 MPDS, p = 0.09). The proportion to the correct depth was greater in the simplified protocol (0.31 versus 0.03, p < 0.01), as was the proportion of compressions done without error (0.05 versus 0.0, p = 0.16). Time to start of chest compressions and total hands-off chest time were better in the simplified protocol (start time 60.9s versus 78.6s, p < 0.0001; hands-off chest time 69 s versus 95 s, p < 0.0001). The proportion with correct hand position, however, was worse in the simplified protocol (0.35 versus 0.84, p < 0.01). CONCLUSIONS: The simplified protocol was as good as, or better than the MPDS v11.2 protocol in every aspect studied except hand position, and the simplified protocol resulted in significant time savings. The protocol may need modification to ensure correct hand position. Time savings and improved quality of CPR achieved by the new set of instructions could be important in strengthening critical links in the cardiac chain of survival.

Adult↗

Dosimetric evaluation of a variable field electron beam applicator.

A commercially available variable electron beam applicator designed for the Phillips SL-75/20 linear accelerator was tested for possible clinical use. The basic design of this collimator consists of four movable L-shaped stainless steel blades forming the corners. In addition, four smaller fixed blades of the same material and thickness fill in the sides. Film placed in polystyrene phantoms were exposed in all experiments. Field size, field flatness, beam homogeneity and penumbra measurements, all indicated that the applicator is acceptable for clinical use. However, for use with large field sizes and/or high energy electron beams some minor modifications are suggested.

Electrons↗