Bioresorbable implants--practical considerations.

Traditional metal implants, primarily used for internal fixation, have been used by the orthopedic surgeon for years. Decades of development have produced such devices for almost every conceivable need. Despite their widespread use, a relatively consistent set of problems or issues have been identified. These include the potential for long term migration, breakage, stress shielding, reaction to the material, interference with standard imaging techniques, and growth restriction in young patients. A number of bioresorbable polymer devices have recently become available to create a viable alternative for some indications. As expected with an evolving technology, solving one set of problems has engendered another. One of the most limiting aspects of bioresorbable polymers is their inherently lower strength compared to metals. Although more of an issue with some materials and applications than others, significant tissue reactions have been observed in some cases as well. This paper discusses the field of synthetic bioresorbable polymers in general, but with specific reference to those materials and devices that can be used in place of metal implants for internal fixation.

Absorption

A comparative biomechanical analysis of resorbable rigid fixation versus titanium rigid fixation of metacarpal fractures.

Linear (two-dimensional) and three-dimensional (3D) plating systems (Poly-Medics) composed of the resorbable copolymer of polyglycolic acid (PGA) and poly-l-lactic acid (PLLA) (Lactosorb) were studied in vitro. The plates were applied to osteotomized fresh frozen human cadaveric metacarpal bones that were then tested for torsional rigidity and three-point bending strength and rigidity. The results were compared to those from another study of two low-profile titanium plating systems (Leibinger and Synthes). Analysis of variance revealed that the linear-flat Lactosorb plate and screws had apex dorsal rigidity and force-to-displacement measurements equal to all but two of the titanium plates (3D). The 3D-flat Lactosorb plate had the highest torsional rigidity of the resorbable system, but it was only moderately rigid compared to the titanium plating systems. This in vitro biomechanical study of the copolymer PGA-PLLA plating system indicates that, in clinical applications, it may be better suited for metacarpal fractures rather than proximal phalangeal fractures due to the lower demands of torsional loading compared to apex bending.

Biomechanical Phenomena